Detection of acute myocardial ischemia during percutaneous transluminal coronary angioplasty by endocardial acceleration

被引:12
|
作者
Theres, HP
Kaiser, DR
Nelson, SD
Glos, M
Leuthold, T
Baumann, G
Sowelam, S
Sheldon, TJ
Stylos, L
机构
[1] Humboldt Univ, Charite, D-1086 Berlin, Germany
[2] Medtronic Inc, CRM Pacing & Monitoring Res, Minneapolis, MN USA
来源
关键词
first heart sound; endocardial acceleration; contractility; myocardial ischemia;
D O I
10.1111/j.1540-8159.2004.00496.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The first heart sound is generated by vibrations from the myocardium during isovolumic contraction. Peak endocardiol acceleration (PEA) has been used previously to measure these vibrations in humans and correlates with myocardial contractility during inotropic interventions. It is unknown if changes in PEA can be used to characterize a reduction in contractility during ischemic episodes. This study was designed to evaluate the use of an endocardial accelerometer for the detection of acute myocardial ischemia. Thirteen patients undergoing routine percutaneous transluminal coronary angioplasty (PTCA) consented to having a single-axis, lead-based accelerometer positioned in the right ventricular apex. PEA was defined as the maximum peak-to-peuk amplitude during a window 50 ms before to 200 ms following the peak R wave. Time of endocardial acceleration (TEA) was defined as the time from the peak R wave to the maximum accelerometer signal within this window To obtain a more robust estimate of the strength of vibrations, a 100-beat template of the accelerometer signal was constructed at baseline and applied as a matched filter during ischemia. The peak magnitude of the filtered endocardial accelerometer signal (Max Filtered EA) was used as an index of signal intensity Median baseline PEA, TEA, and Max Filtered EA were 0.91 +/- 0.35 g, 75.2 +/- 16.2 ms, and 0.40 +/- 0.20 g, respectively. PEA and Max Filtered EA significantly decreased by 7% during ischemia (0,91 to 0.85 g and 0.40 to 0.37 g both P < 0.05, respectively). TEA did not significantly change from baseline (77.0 ms, P = ns). The results of this study suggest that acute ischemia can be detected with on endocardial accelerometer in humans.
引用
收藏
页码:621 / 625
页数:5
相关论文
共 50 条
  • [21] Women react with more myocardial ischemia and angina pectoris during elective percutaneous transluminal coronary angioplasty
    Jensen, J
    Eriksson, SV
    Lindvall, B
    Lundin, P
    Sylvén, C
    CORONARY ARTERY DISEASE, 2000, 11 (07) : 527 - 535
  • [22] Percutaneous transluminal coronary angioplasty, alone or in combination with urokinase therapy, during acute myocardial infarction
    Oshima, S
    Saito, T
    Nakamura, S
    Noda, K
    Date, H
    Hokimoto, S
    Taniguchi, I
    Yamamoto, N
    JAPANESE CIRCULATION JOURNAL-ENGLISH EDITION, 1999, 63 (02): : 91 - 96
  • [23] Effect of hypnotic sedation during percutaneous transluminal coronary angioplasty on myocardial ischemia and cardiac sympathetic drive
    Baglini, R
    Sesana, M
    Capuano, C
    Gnecchi-Ruscone, T
    Ugo, L
    Danzi, GB
    AMERICAN JOURNAL OF CARDIOLOGY, 2004, 93 (08): : 1035 - 1038
  • [24] Myocardial ischemia during percutaneous transluminal coronary angioplasty in patients with rich collateral circulation of the target lesion
    Watarai, M
    Takatsu, F
    Horibe, H
    Yanase, M
    Takemoto, K
    Shimizu, S
    Shiga, Y
    CIRCULATION JOURNAL, 2002, 66 (06) : 534 - 536
  • [25] MYOCARDIAL PROTECTION DURING PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY - EFFECTS OF TRIMETAZIDINE
    KOBER, G
    BUCK, T
    SIEVERT, H
    VALLBRACHT, C
    EUROPEAN HEART JOURNAL, 1992, 13 (08) : 1109 - 1115
  • [26] LATE OUTCOME AFTER PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY DURING ACUTE MYOCARDIAL-INFARCTION
    OMURCHU, B
    GERSH, BJ
    REEDER, GS
    BAILEY, KR
    HOLMES, DR
    AMERICAN JOURNAL OF CARDIOLOGY, 1993, 72 (09): : 634 - 639
  • [27] Comparison of ST-segment deviation to scintigraphically quantified myocardial ischemia during acute coronary occlusion induced by percutaneous transluminal coronary angioplasty
    Persson, E
    Pettersson, J
    Ringborn, M
    Sörnmo, L
    Warren, SG
    Wagner, GS
    Maynard, C
    Pahlm, O
    AMERICAN JOURNAL OF CARDIOLOGY, 2006, 97 (03): : 295 - 300
  • [28] New electrocardiographic criteria for posterior wall acute myocardial ischemia validated by a percutaneous transluminal coronary angioplasty model of acute myocardial infarction
    Wung, SF
    Drew, BJ
    AMERICAN JOURNAL OF CARDIOLOGY, 2001, 87 (08): : 970 - 974
  • [29] SYMPTOMATIC AND SILENT-MYOCARDIAL-ISCHEMIA BEFORE AND AFTER PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY
    EISOLD, S
    GONSKA, BD
    KREUZER, H
    ZEITSCHRIFT FUR KARDIOLOGIE, 1994, 83 (11): : 816 - 823
  • [30] QRS prolongation: A sensitive marker of ischemia during percutaneous transluminal coronary angioplasty
    Cantor, AA
    Goldfarb, B
    Ilia, R
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2000, 50 (02) : 177 - 183