Signal enhancement in amperometric peroxide detection by using graphene materials with low number of defects

被引:10
|
作者
Zoepfl, Alexander [1 ]
Sisakthi, Masoumeh [2 ]
Eroms, Jonathan [2 ]
Matysik, Frank-Michael [1 ]
Strunk, Christoph [2 ]
Hirsch, Thomas [1 ]
机构
[1] Univ Regensburg, Inst Analyt Chem Chemo & Biosensors, Univ Str 31, D-93053 Regensburg, Germany
[2] Univ Regensburg, Inst Expt & Appl Phys, Micro & Nanophys, D-93053 Regensburg, Germany
关键词
Graphene; Reduced graphene oxide; Hydrogen peroxide; Amperometry; Electrical impedance spectroscopy; Chronocoulometry; Cyclic voltammetry; Raman spectroscopy; OXIDE; NANOPARTICLES; CARBON; FILMS; NANOSHEETS; GRAPHITE; ROADMAP;
D O I
10.1007/s00604-015-1600-y
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Two-dimensional carbon nanomaterials ranging from single-layer graphene to defective structures such as chemically reduced graphene oxide were studied with respect to their use in electrodes and sensors. Their electrochemical properties and utility in terms of fabrication of sensing devices are compared. Specifically, the electrodes have been applied to reductive amperometric determination of hydrogen peroxide. Low-defect graphene (SG) was obtained through mechanical exfoliation of natural graphite, while higher-defect graphenes were produced by chemical vapor deposition (CVDG) and by chemical oxidation of graphite and subsequent reduction (rGO). The carbonaceous materials were mainly characterized by Raman microscopy. They were applied as electrode material and the electrochemical behavior was investigated by chronocoulometry, cyclic voltammetry, electrochemical impedance spectroscopy and amperometry and compared to a carbon disc electrode. It is shown that the quality of the graphene has an enormous impact on the amperometric performance. The use of carbon materials with many defects (like rGO) does not result in a significant improvement in signal compared to a plain carbon disc electrode. The sensitivity is 173 mA center dot M-1 center dot cm(-2) in case of using CVDG which is about 50 times better than that of a plain carbon disc electrode and about 7 times better than that of rGO. The limit of detection for hydrogen peroxide is 15.1 mu M (at a working potential of -0.3 V vs SCE) for CVDG. It is concluded that the application of two-dimensional carbon nanomaterials offers large perspectives in amperometric detection systems due to electrocatalytic effects that result in highly sensitive detection.
引用
收藏
页码:83 / 90
页数:8
相关论文
共 50 条
  • [41] Graphene Metasurfaces-Based Surface Plasmon Resonance Biosensor for Virus Detection with Sensitivity Enhancement Using Perovskite Materials
    Wekalao, Jacob
    Patel, Shobhit K.
    Al-zahrani, Fahad Ahmed
    PLASMONICS, 2024,
  • [42] Amperometric hydrogen peroxide and cholesterol biosensors designed by using hierarchical curtailed silver flowers functionalized graphene and enzymes deposits
    Nalini, Seetharamaiah
    Nandini, Seetharamaiah
    Shanmugam, Sangaraju
    Neelagund, Shivayogeeswar E.
    Melo, Jose Savio
    Suresh, Gurukar Shivappa
    JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2014, 18 (03) : 685 - 701
  • [43] Amperometric detection of glucose using Prussian blue-graphene oxide modified platinum electrode
    Mohan, A. M. Vinu
    Aswini, K. K.
    Starvin, A. Maria
    Biju, V. M.
    ANALYTICAL METHODS, 2013, 5 (07) : 1764 - 1770
  • [44] A novel method for the detection of the number of signals at low signal-to-noise ratios
    Hou Y.-S.
    Huang J.-G.
    Shi W.-T.
    Dianzi Yu Xinxi Xuebao/Journal of Electronics and Information Technology, 2011, 33 (06): : 1390 - 1394
  • [45] Remote Sensing Low Signal-to-Noise-Ratio Target Detection Enhancement
    Ma, Tian J.
    Anderson, Robert J.
    SENSORS, 2023, 23 (06)
  • [46] Galvanostatic deposition of Pt nanoparticles on TiO2 nanotube arrays for amperometric detection of hydrogen peroxide at low overpotentials
    Liu, Jiaqin
    Ruan, Lili
    Xu, Guangqing
    Lv, Jun
    Wu, Yucheng
    EIGHTH CHINA NATIONAL CONFERENCE ON FUNCTIONAL MATERIALS AND APPLICATIONS, 2014, 873 : 174 - 182
  • [47] Raman Signal Enhancement for Liquid Detection Using a New Sample Cell
    Si Gan-Shang
    Liu Jia-xiang
    Li Zhen-gang
    Ning Zhi-qiang
    Fang Yong-hua
    Cheng Zhen
    Si Bei-bei
    Yang Chang-ping
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43 (03) : 712 - 717
  • [48] Raman Signal Enhancement for Gas Detection Using a Near Concentric Cavity
    Yang De-wang
    Guo Jin-jia
    Du Zeng-feng
    Wang Zhen-nan
    Zheng Rong-er
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2015, 35 (03) : 645 - 648
  • [49] Fabrication of Tetra-Substituted Copper(II) Phthalocyanine-Graphene Modified Pencil Graphite Electrode for Amperometric Detection of Hydrogen Peroxide
    Gorduk, Ozge
    Gorduk, Semih
    Sahin, Yucel
    ECS JOURNAL OF SOLID STATE SCIENCE AND TECHNOLOGY, 2020, 9 (06)
  • [50] Enhancement of phased array ultrasonic signal in composite materials using TMST algorithm
    Benammar, Abdessalem
    Drai, Redouane
    Kechida, Ahmed
    Dris, Lyamine
    Chibane, Farid
    PROCEEDINGS OF THE 2015 ICU INTERNATIONAL CONGRESS ON ULTRASONICS, 2015, 70 : 488 - 491