Signal enhancement in amperometric peroxide detection by using graphene materials with low number of defects

被引:10
|
作者
Zoepfl, Alexander [1 ]
Sisakthi, Masoumeh [2 ]
Eroms, Jonathan [2 ]
Matysik, Frank-Michael [1 ]
Strunk, Christoph [2 ]
Hirsch, Thomas [1 ]
机构
[1] Univ Regensburg, Inst Analyt Chem Chemo & Biosensors, Univ Str 31, D-93053 Regensburg, Germany
[2] Univ Regensburg, Inst Expt & Appl Phys, Micro & Nanophys, D-93053 Regensburg, Germany
关键词
Graphene; Reduced graphene oxide; Hydrogen peroxide; Amperometry; Electrical impedance spectroscopy; Chronocoulometry; Cyclic voltammetry; Raman spectroscopy; OXIDE; NANOPARTICLES; CARBON; FILMS; NANOSHEETS; GRAPHITE; ROADMAP;
D O I
10.1007/s00604-015-1600-y
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Two-dimensional carbon nanomaterials ranging from single-layer graphene to defective structures such as chemically reduced graphene oxide were studied with respect to their use in electrodes and sensors. Their electrochemical properties and utility in terms of fabrication of sensing devices are compared. Specifically, the electrodes have been applied to reductive amperometric determination of hydrogen peroxide. Low-defect graphene (SG) was obtained through mechanical exfoliation of natural graphite, while higher-defect graphenes were produced by chemical vapor deposition (CVDG) and by chemical oxidation of graphite and subsequent reduction (rGO). The carbonaceous materials were mainly characterized by Raman microscopy. They were applied as electrode material and the electrochemical behavior was investigated by chronocoulometry, cyclic voltammetry, electrochemical impedance spectroscopy and amperometry and compared to a carbon disc electrode. It is shown that the quality of the graphene has an enormous impact on the amperometric performance. The use of carbon materials with many defects (like rGO) does not result in a significant improvement in signal compared to a plain carbon disc electrode. The sensitivity is 173 mA center dot M-1 center dot cm(-2) in case of using CVDG which is about 50 times better than that of a plain carbon disc electrode and about 7 times better than that of rGO. The limit of detection for hydrogen peroxide is 15.1 mu M (at a working potential of -0.3 V vs SCE) for CVDG. It is concluded that the application of two-dimensional carbon nanomaterials offers large perspectives in amperometric detection systems due to electrocatalytic effects that result in highly sensitive detection.
引用
收藏
页码:83 / 90
页数:8
相关论文
共 50 条
  • [31] MnO2/reduced graphene oxide nanoribbons: Facile hydrothermal preparation and their application in amperometric detection of hydrogen peroxide
    Wu, Zhi-Liang
    Li, Cheng-Kun
    Yu, Jin-Gang
    Chen, Xiao-Qing
    SENSORS AND ACTUATORS B-CHEMICAL, 2017, 239 : 544 - 552
  • [32] Detection and diagnosis of bearing defects using vibration signal processing
    Bouaouiche, Karim
    Menasria, Yamina
    Khalfa, Dalila
    ARCHIVE OF MECHANICAL ENGINEERING, 2023, 70 (03) : 433 - 452
  • [33] A sensitive amperometric immunosensor for the detection of carcinoembryonic antigen using ZnMn2O4@reduced graphene oxide composites as signal amplifier
    Fan, Xinxia
    Deng, Dongmei
    Chen, Zichao
    Qi, Ji
    Li, Yuanyuan
    Han, Baosan
    Huan, Ke
    Luo, Liqiang
    SENSORS AND ACTUATORS B-CHEMICAL, 2021, 339
  • [34] A sensitive amperometric immunosensor for the detection of carcinoembryonic antigen using ZnMn2O4@reduced graphene oxide composites as signal amplifier
    Fan, Xinxia
    Deng, Dongmei
    Chen, Zichao
    Qi, Ji
    Li, Yuanyuan
    Han, Baosan
    Huan, Ke
    Luo, Liqiang
    Sensors and Actuators, B: Chemical, 2021, 339
  • [36] Low-Cost Carbon Paste Cu(II)-Exchanged Zeolite Amperometric Sensor for Hydrogen Peroxide Detection
    Gligor, Delia
    Maicaneanu, Sanda Andrada
    Varodi, Codruta
    CHEMOSENSORS, 2024, 12 (02)
  • [37] DETECTION OF DEFECTS IN FABRICS AND KNITTED MATERIALS UNDER LOW AND HIGH MAGNIFICATION
    MAHALL, K
    TEXTILVEREDLUNG, 1975, 10 (04): : 150 - 159
  • [38] Micro defects detection in metallic materials based on recurrence analysis of ultrasonic backscattering signal
    Yang C.-L.
    Feng W.
    Bian C.-L.
    Zhou X.-J.
    Chai J.-Y.
    Guangxue Jingmi Gongcheng/Optics and Precision Engineering, 2019, 27 (04): : 932 - 944
  • [39] Electrocatalytic Activity Enhancement Using Graphene-Metal Oxide Nanocomposites for the Ultra Low Level Detection of Biomolecules
    Joseph, Teena
    Thomas, Jasmine
    Thomas, Tony
    Thomas, Nygil
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2022, 169 (02)
  • [40] Amperometric hydrogen peroxide and cholesterol biosensors designed by using hierarchical curtailed silver flowers functionalized graphene and enzymes deposits
    Seetharamaiah Nalini
    Seetharamaiah Nandini
    Sangaraju Shanmugam
    Shivayogeeswar E. Neelagund
    Jose Savio Melo
    Gurukar Shivappa Suresh
    Journal of Solid State Electrochemistry, 2014, 18 : 685 - 701