Signal enhancement in amperometric peroxide detection by using graphene materials with low number of defects

被引:10
|
作者
Zoepfl, Alexander [1 ]
Sisakthi, Masoumeh [2 ]
Eroms, Jonathan [2 ]
Matysik, Frank-Michael [1 ]
Strunk, Christoph [2 ]
Hirsch, Thomas [1 ]
机构
[1] Univ Regensburg, Inst Analyt Chem Chemo & Biosensors, Univ Str 31, D-93053 Regensburg, Germany
[2] Univ Regensburg, Inst Expt & Appl Phys, Micro & Nanophys, D-93053 Regensburg, Germany
关键词
Graphene; Reduced graphene oxide; Hydrogen peroxide; Amperometry; Electrical impedance spectroscopy; Chronocoulometry; Cyclic voltammetry; Raman spectroscopy; OXIDE; NANOPARTICLES; CARBON; FILMS; NANOSHEETS; GRAPHITE; ROADMAP;
D O I
10.1007/s00604-015-1600-y
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Two-dimensional carbon nanomaterials ranging from single-layer graphene to defective structures such as chemically reduced graphene oxide were studied with respect to their use in electrodes and sensors. Their electrochemical properties and utility in terms of fabrication of sensing devices are compared. Specifically, the electrodes have been applied to reductive amperometric determination of hydrogen peroxide. Low-defect graphene (SG) was obtained through mechanical exfoliation of natural graphite, while higher-defect graphenes were produced by chemical vapor deposition (CVDG) and by chemical oxidation of graphite and subsequent reduction (rGO). The carbonaceous materials were mainly characterized by Raman microscopy. They were applied as electrode material and the electrochemical behavior was investigated by chronocoulometry, cyclic voltammetry, electrochemical impedance spectroscopy and amperometry and compared to a carbon disc electrode. It is shown that the quality of the graphene has an enormous impact on the amperometric performance. The use of carbon materials with many defects (like rGO) does not result in a significant improvement in signal compared to a plain carbon disc electrode. The sensitivity is 173 mA center dot M-1 center dot cm(-2) in case of using CVDG which is about 50 times better than that of a plain carbon disc electrode and about 7 times better than that of rGO. The limit of detection for hydrogen peroxide is 15.1 mu M (at a working potential of -0.3 V vs SCE) for CVDG. It is concluded that the application of two-dimensional carbon nanomaterials offers large perspectives in amperometric detection systems due to electrocatalytic effects that result in highly sensitive detection.
引用
收藏
页码:83 / 90
页数:8
相关论文
共 50 条
  • [1] Signal enhancement in amperometric peroxide detection by using graphene materials with low number of defects
    Alexander Zöpfl
    Masoumeh Sisakthi
    Jonathan Eroms
    Frank-Michael Matysik
    Christoph Strunk
    Thomas Hirsch
    Microchimica Acta, 2016, 183 : 83 - 90
  • [2] Prussian blue-functionalised graphene in the amperometric detection of peroxide and hydrazine
    Keeley, Gareth P.
    O'Neill, Arlene
    Holzinger, Michael
    Cosnier, Serge
    Coleman, Jonathan N.
    Duesberg, Georg S.
    TECHNOLOGY, 2013, 1 (01): : 58 - 62
  • [3] Detection of delamination defects in CFRP materials using ultrasonic signal processing
    Benammar, Abdessalem
    Drai, Redouane
    Guessoum, Abderrezak
    ULTRASONICS, 2008, 48 (08) : 731 - 738
  • [4] Amperometric detection of hydrogen peroxide using InP porous nanostructures
    Sato, Taketomo
    Mizohata, Akinori
    Yoshizawa, Naoki
    Hashizume, Tamotsu
    APPLIED PHYSICS EXPRESS, 2008, 1 (05) : 0512021 - 0512023
  • [5] A amperometric immunosensor for sensitive detection of circulating tumor cells using a tyramide signal amplification-based signal enhancement system
    Zhou, Xiaoyan
    Li, Yujian
    Wu, Haiping
    Huang, Wei
    Ju, Huangxian
    Ding, Shijia
    BIOSENSORS & BIOELECTRONICS, 2019, 130 : 88 - 94
  • [6] Sparse Structural Principal Component Thermography for Defect Signal Enhancement in Subsurface Defects Detection of Composite Materials
    Liu, Wei
    Hou, Beiping
    Wang, Yaoxin
    Yao, Yuan
    Zhou, Le
    JOURNAL OF NONDESTRUCTIVE EVALUATION, 2022, 41 (01)
  • [7] Sparse Structural Principal Component Thermography for Defect Signal Enhancement in Subsurface Defects Detection of Composite Materials
    Wei Liu
    Beiping Hou
    Yaoxin Wang
    Yuan Yao
    Le Zhou
    Journal of Nondestructive Evaluation, 2022, 41
  • [8] Amperometric detection of hydrogen peroxide using a nanofibrous membrane sputtered with silver
    Li, Dawei
    Luo, Lei
    Pang, Zengyuan
    Chen, Xiaodong
    Cai, Yibing
    Wei, Qufu
    RSC ADVANCES, 2014, 4 (08): : 3857 - 3863
  • [9] The detection of defects in materials using thermography
    I. N. Ishchuk
    Measurement Techniques, 2008, 51 : 421 - 427
  • [10] The detection of defects in materials using thermography
    Ishchuk, I. N.
    MEASUREMENT TECHNIQUES, 2008, 51 (04) : 421 - 427