Visualization study of the transient flow in the centrifugal blood pump impeller

被引:10
|
作者
Tsukiya, T [1 ]
Taenaka, Y [1 ]
Tatsumi, E [1 ]
Takano, H [1 ]
机构
[1] Natl Cardiovasc Ctr, Dept Artificial Organs, Suita, Osaka 5658565, Japan
关键词
D O I
10.1097/00002480-200207000-00018
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Rotary blood pumps as a left ventricular assist device have several advantages over the use of existing pulsatile devices used for this purpose. The relative velocity distribution to the rotating impeller was observed by high-speed videography and particle image velocimetry (PIV) with the purpose of characterizing the unsteady fluid motion in the impeller and assessing antithrombogenicity based on the fluid dynamic properties within the flow path. Flow visualization in the present study has clearly shown the existence of drastic transient motion of flows in the impeller. The secondary flows developed in the passage, which are adverse in terms of hydrodynamic efficiency, contributed to the washout conditions on the blood contacting surface.
引用
下载
收藏
页码:431 / 436
页数:6
相关论文
共 50 条
  • [21] FLUCTUATING FLOW BEHIND THE IMPELLER OF CENTRIFUGAL PUMP
    YUASA, T
    HINATA, T
    BULLETIN OF THE JSME-JAPAN SOCIETY OF MECHANICAL ENGINEERS, 1979, 22 (174): : 1746 - 1753
  • [22] FLOW OF CAVITATION BUBBLES IN A CENTRIFUGAL PUMP IMPELLER
    MINEMURA, K
    KIKUYAMA, K
    MURAKAMI, M
    UCHIYAMA, T
    JSME INTERNATIONAL JOURNAL SERIES II-FLUIDS ENGINEERING HEAT TRANSFER POWER COMBUSTION THERMOPHYSICAL PROPERTIES, 1988, 31 (01): : 30 - 38
  • [23] Flow visualization in a centrifugal blood pump with an eccentric inlet port
    Yamane, T
    Kodama, T
    Yamamoto, Y
    Shinohara, T
    Nosé, Y
    ARTIFICIAL ORGANS, 2004, 28 (06) : 564 - 570
  • [24] Improvement of washout flow in a centrifugal blood pump by a semi-open impeller
    Tsukiya, T.
    Taenaka, Y.
    Tatsumi, E.
    Takano, H.
    ASAIO Journal, 2000, 46 (02)
  • [25] Improvement of washout flow in a centrifugal blood pump by a semi-open impeller
    Tsukiya, T
    Taenaka, Y
    Tatsumi, E
    Takano, H
    ASAIO JOURNAL, 2002, 48 (01) : 76 - 82
  • [26] Study on transient cavitation performance of centrifugal pump based on the influence of rough impeller
    Gu, Jintong
    Sun, Huihui
    Yao, Yuan
    Chen, Qing
    Zeng, Yong
    Lu, Qian
    Fu, Shifeng
    PHYSICS OF FLUIDS, 2024, 36 (08)
  • [27] Numerical study of flow characteristics in the impeller side chamber of centrifugal pump
    College of Fluid Power and Control Engineering, Lanzhou University of Technology, Lanzhou 730050, China
    不详
    Nongye Jixie Xuebao, 2009, 4 (86-90):
  • [28] Numerical simulation and experiment study for turbulent flow in the impeller of centrifugal pump
    Yang, Minguan
    Gu, Haifei
    Liu, Dong
    Jia, Weidong
    Gao, Bo
    Jixie Gongcheng Xuebao/Chinese Journal of Mechanical Engineering, 2006, 42 (12): : 180 - 185
  • [29] Flow visualization study on centrifugal blood pump using a high speed video camera
    Sakuma, I.
    Tadokoro, H.
    Fukui, Y.
    Dohi, T.
    1995, (19)
  • [30] Quantitative visualization study of flow in a scaled-up model of a centrifugal blood pump
    Ikeda, T
    Yamane, T
    Orita, T
    Tateishi, T
    ARTIFICIAL ORGANS, 1996, 20 (02) : 132 - 138