Beam-specific planning target volumes incorporating 4D CT for pencil beam scanning proton therapy of thoracic tumors

被引:60
|
作者
Lin, Liyong [1 ]
Kang, Minglei [1 ]
Huang, Sheng [1 ]
Mayer, Rulon [2 ]
Thomas, Andrew [3 ]
Solberg, Timothy D. [1 ]
McDonough, Jame E. [1 ]
Simone, Charles B., II [1 ]
机构
[1] Univ Penn, Dept Radiat Oncol, Philadelphia, PA 19104 USA
[2] Henry Jackson Fdn, Bethesda, MD USA
[3] ATC Healthcare, Washington, DC USA
来源
关键词
4D CT; beam-specific PTV; treatment planning; proton therapy; pencil beam scanning; interplay; RESPIRATORY MOTION; TREATMENT UNCERTAINTIES; PARTICLE THERAPY; SPOT SIZE; LUNG; CANCER; DELIVERY; RADIOTHERAPY; SENSITIVITY; MANAGEMENT;
D O I
10.1120/jacmp.v16i6.5678
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of this study is to determine whether organ sparing and target coverage can be simultaneously maintained for pencil beam scanning (PBS) proton therapy treatment of thoracic tumors in the presence of motion, stopping power uncertainties, and patient setup variations. Ten consecutive patients that were previously treated with proton therapy to 66.6/1.8 Gy (RBE) using double scattering (DS) were replanned with PBS. Minimum and maximum intensity images from 4D CT were used to introduce flexible smearing in the determination of the beam specific PTV (BSPTV). Datasets from eight 4D CT phases, using +/- 3% uncertainty in stopping power and +/- 3 mm uncertainty in patient setup in each direction, were used to create 8 x 12 x 10 = 960 PBS plans for the evaluation of 10 patients. Plans were normalized to provide identical coverage between DS and PBS. The average lung V20, V5, and mean doses were reduced from 29.0%, 35.0%, and 16.4 Gy with DS to 24.6%, 30.6%, and 14.1 Gy with PBS, respectively. The average heart V30 and V45 were reduced from 10.4% and 7.5% in DS to 8.1% and 5.4% for PBS, respectively. Furthermore, the maximum spinal cord, esophagus, and heart doses were decreased from 37.1 Gy, 71.7 Gy, and 69.2 Gy with DS to 31.3 Gy, 67.9 Gy, and 64.6 Gy with PBS. The conformity index (CI), homogeneity index (HI), and global maximal dose were improved from 3.2, 0.08, 77.4 Gy with DS to 2.8, 0.04, and 72.1 Gy with PBS. All differences are statistically significant, with p-values < 0.05, with the exception of the heart V45 (p = 0.146). PBS with BSPTV achieves better organ sparing and improves target coverage using a repainting method for the treatment of thoracic tumors. Incorporating motion-related uncertainties is essential.
引用
收藏
页码:281 / 292
页数:12
相关论文
共 50 条
  • [1] Beam Specific Planning Target Volumes Incorporating 4DCT for Pencil Beam Scanning Proton Therapy of Thoracic Tumors
    Lin, L.
    Kang, M.
    Huang, S.
    Mayer, R.
    Thomas, A.
    McDonough, J.
    Solberg, T.
    Simone, C.
    [J]. MEDICAL PHYSICS, 2015, 42 (06) : 3365 - 3365
  • [2] Incorporating Beam-Specific Target Volumes Into Beam Angle Selection in Proton Therapy
    Park, P.
    Zhu, X.
    Sahoo, N.
    Lee, A.
    Zhang, L.
    Cheung, J.
    Dong, L.
    [J]. MEDICAL PHYSICS, 2011, 38 (06)
  • [3] Implementation of 4D proton therapy treatments with pencil beam scanning (PBS)
    Fracchiolla, F.
    Dionisi, F.
    Hild, S.
    Giacomelli, I.
    Lorentini, S.
    Engwall, E.
    Esposito, P. G.
    Amichetti, M.
    Schwarz, M.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S1110 - S1111
  • [4] A study of the beam-specific interplay effect in proton pencil beam scanning delivery in lung cancer
    Kang, Minglei
    Huang, Sheng
    Solberg, Timothy D.
    Mayer, Rulon
    Thomas, Andy
    Teo, Boon-Keng Kevin
    McDonough, James E.
    Simone, Charles B., II
    Lin, Liyong
    [J]. ACTA ONCOLOGICA, 2017, 56 (04) : 531 - 540
  • [5] A Study of the Beam-Specific Interplay Effect in Proton Pencil Beam Scanning Delivery in Lung Cancer
    Kang, M.
    Huang, S.
    Solberg, T. D.
    Mayer, R.
    Thomas, A.
    Teo, B. K.
    McDonough, J.
    Simone, C. B., II
    Lin, L.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2016, 96 (02): : S211 - S211
  • [6] Beam-specific planning volumes for scattered-proton lung radiotherapy
    Flampouri, S.
    Hoppe, B. S.
    Slopsema, R. L.
    Li, Z.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (16): : 4549 - 4566
  • [7] A Beam-Specific Optimization Target Volume for Stereotactic Proton Pencil Beam Sanning Therapy for Locally Advanced Pancreatic Cancer
    Han, Dong
    Hooshangnejad, Hamed
    Chen, Chin-Cheng
    Ding, Kai
    [J]. ADVANCES IN RADIATION ONCOLOGY, 2021, 6 (06)
  • [8] Experimental validation of a 4D dose calculation routine for pencil beam scanning proton therapy
    Pfeiler, Tina
    Baeumer, Christian
    Engwall, Erik
    Geismar, Dirk
    Spaan, Bernhard
    Timmermann, Beate
    [J]. ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2018, 28 (02): : 121 - 133
  • [9] Application of Beam-specific PTV in Proton Therapy Treatment Planning
    Song, X.
    Zhang, L.
    Park, P. C.
    Zhu, R. X.
    Sahoo, N.
    Gillin, M. T.
    Dong, L.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 84 (03): : S848 - S849
  • [10] Treatment Planning of Bulky Tumors Using Pencil Beam Scanning Proton GRID Therapy
    Halthore, Aditya
    Fellows, Zachary
    Tran, Anh
    Deville, Curtiland, Jr.
    Wright, Jean L.
    Meyer, Jeffrey
    Li, Heng
    Sheikh, Khadija
    [J]. INTERNATIONAL JOURNAL OF PARTICLE THERAPY, 2023, 9 (03) : 40 - 49