Clinical study of the laser sheath for lead extraction: The total experience in the United States

被引:230
|
作者
Byrd, CL
Wilkoff, BL
Love, CJ
Sellers, TD
Reiser, C
机构
[1] Spectranetics, Colorado Springs, CO 80907 USA
[2] Broward Gen Med Ctr, Ft Lauderdale, FL USA
[3] Cleveland Clin Fdn, Cleveland, OH 44195 USA
[4] Ohio State Univ, Med Ctr, Columbus, OH 43210 USA
[5] Mem Hosp, Colorado Springs, CO USA
来源
关键词
pacing lead; defibrillator lead; lead removal; ultraviolet;
D O I
10.1046/j.1460-9592.2002.t01-1-00804.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The laser sheath uses optical fibers, delivering pulsed ultraviolet excimer laser light, to vaporize fibrotic tissue binding intravenous cardiac leads to the vein or heart wall during lead extraction from the implant vein. The total investigational experience with laser sheaths is reported. During the period from October 1995 to December 1999, 2,561 pacing and defibrillator leads were treated in 1,684 patients at 89 sites in the United States with three sizes of laser sheath. Endpoints were complete removal of the lead, partial removal (leaving the tip behind), or failure (abandoning the lead, onset of complications, change to transfemoral or transatrial approach). Minimal follow-up at 30 days was recorded. Of the leads, 90% were completely removed, 3% were partially removed, and the balance were failures. Major perioperative complications (tamponade, hemothorax, pulmonary embolism, lead migration, and death) were observed in 1.9% of patients with in hospital death in 13 (0.8%). Minor complications were seen in an additional 1.4% of patients. Multivariate analysis showed that implant duration was the only preoperative independent predictor of failure; female sex was the only multivariate predictor of complications. Success and complications were not dependent on laser sheath size. At follow-up, various extraction related complications were observed in 2% of patients. The learning curve showed a trend toward fewer complications with experience. Lead extraction with the laser sheath can be safely practiced with high success rates. Success is independent of laser sheath size. Major complications can be expected in < 2% of patients, and occur more often during an investigator's early experience.
引用
收藏
页码:804 / 808
页数:5
相关论文
共 50 条
  • [31] Use of a laser sheath to obtain venous access in pacemaker lead-related obstruction without extraction of the lead
    Bracke, FALE
    Meijer, A
    van Gelder, LM
    EUROPACE, 2002, 4 (01): : 67 - 68
  • [32] EXPERIENCE WITH THE SPRINT FIDELIS LEAD RECALL IN A SINGLE CANADIAN LASER LEAD EXTRACTION CENTRE
    Bashir, J.
    Yamashita, M.
    Karim, S. S.
    Tung, S.
    Yeung-Lai-Wah, J.
    Chakrabarti, S.
    Hahn, E.
    Sanatani, S.
    Kerr, C.
    CANADIAN JOURNAL OF CARDIOLOGY, 2011, 27 (05) : S281 - S282
  • [33] Total Laser Cycles - A Novel Measure of Transvenous Lead Extraction Difficulty
    Elsaid, Ossama
    O'Sullivan, David
    Zweibel, Steven
    Cronin, Edmond
    CIRCULATION, 2017, 136
  • [34] Initial experience with the Tightrail rotating mechanical dilator sheath for transvenous lead extraction: safety and efficacy
    Aytemir, K.
    Yorgun, H.
    Canpolat, U.
    Sahiner, M. L.
    Kaya, E. B.
    Evranos, B.
    Ozer, N.
    EUROPEAN HEART JOURNAL, 2015, 36 : 821 - 822
  • [35] CLINICAL-EXPERIENCE WITH FLUPIRTINE IN THE UNITED-STATES
    MCMAHON, FG
    ARNDT, WF
    NEWTON, JJ
    MONTGOMERY, PA
    PERHACH, JL
    POSTGRADUATE MEDICAL JOURNAL, 1987, 63 : 81 - 85
  • [36] CLINICAL-EXPERIENCE WITH IOPAMIDOL IN THE UNITED-STATES
    ALEXANDER, JC
    NEWMAN, TJ
    SUDILOVSKY, A
    MEYER, JH
    INVESTIGATIVE RADIOLOGY, 1984, 19 (04) : S146 - S146
  • [37] Initial experience in the extraction of chronically implanted pacemaker leads using the Excimer laser sheath
    Levy, T
    Walker, S
    Paul, V
    HEART, 1999, 82 (01) : 101 - 104
  • [38] Environmental intervention in sites contaminated by lead: The United States of America experience
    Ceto, N
    SALUD PUBLICA DE MEXICO, 2003, 45 : S232 - S236
  • [39] Pacernaker/ICD lead extraction using the Excimer laser sheath: What are the advantages and what are the risks?
    Gasparini, G
    Rossillo, A
    Giada, F
    Corrado, A
    Raviele, A
    CARDIAC ARRHYTHMIAS 2003, 2004, : 897 - 902
  • [40] Conductor externalization of the RIATA implantable cardioverter defibrillator lead: a challenging lead extraction requiring laser-powered sheath
    Migliore, Federico
    Bertaglia, Emanuele
    Bontempi, Luca
    Verlato, Roberto
    Leoni, Loira
    Iliceto, Sabino
    Curnis, Antonio
    JOURNAL OF CARDIOVASCULAR MEDICINE, 2013, 14 (10) : 755 - 756