Clinical study of the laser sheath for lead extraction: The total experience in the United States

被引:230
|
作者
Byrd, CL
Wilkoff, BL
Love, CJ
Sellers, TD
Reiser, C
机构
[1] Spectranetics, Colorado Springs, CO 80907 USA
[2] Broward Gen Med Ctr, Ft Lauderdale, FL USA
[3] Cleveland Clin Fdn, Cleveland, OH 44195 USA
[4] Ohio State Univ, Med Ctr, Columbus, OH 43210 USA
[5] Mem Hosp, Colorado Springs, CO USA
来源
关键词
pacing lead; defibrillator lead; lead removal; ultraviolet;
D O I
10.1046/j.1460-9592.2002.t01-1-00804.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The laser sheath uses optical fibers, delivering pulsed ultraviolet excimer laser light, to vaporize fibrotic tissue binding intravenous cardiac leads to the vein or heart wall during lead extraction from the implant vein. The total investigational experience with laser sheaths is reported. During the period from October 1995 to December 1999, 2,561 pacing and defibrillator leads were treated in 1,684 patients at 89 sites in the United States with three sizes of laser sheath. Endpoints were complete removal of the lead, partial removal (leaving the tip behind), or failure (abandoning the lead, onset of complications, change to transfemoral or transatrial approach). Minimal follow-up at 30 days was recorded. Of the leads, 90% were completely removed, 3% were partially removed, and the balance were failures. Major perioperative complications (tamponade, hemothorax, pulmonary embolism, lead migration, and death) were observed in 1.9% of patients with in hospital death in 13 (0.8%). Minor complications were seen in an additional 1.4% of patients. Multivariate analysis showed that implant duration was the only preoperative independent predictor of failure; female sex was the only multivariate predictor of complications. Success and complications were not dependent on laser sheath size. At follow-up, various extraction related complications were observed in 2% of patients. The learning curve showed a trend toward fewer complications with experience. Lead extraction with the laser sheath can be safely practiced with high success rates. Success is independent of laser sheath size. Major complications can be expected in < 2% of patients, and occur more often during an investigator's early experience.
引用
收藏
页码:804 / 808
页数:5
相关论文
共 50 条
  • [21] TOTAL ANDROGEN BLOCKADE - THE UNITED-STATES EXPERIENCE
    BENSON, RC
    EUROPEAN UROLOGY, 1993, 24 : 72 - 76
  • [22] Comparison of Outcomes of Transvenous Lead Extraction Using an Excimer Laser Sheath vs the Tightrail Rotating Dilator Sheath
    Misra, Satish
    Swayampakala, Kamala
    Coons, Tricia
    Cerbie, Claire
    Lesiczka, Magdalena
    Holshouser, John W.
    Mehta, Rohit
    CIRCULATION, 2019, 140
  • [23] Total laser cyclesa measure of transvenous lead extraction difficulty
    Elsaid, Ossama
    O'Sullivan, David M.
    Zweibel, Steven
    Cronin, Edmond M.
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2018, 53 (03) : 383 - 389
  • [24] Total laser cycles—a measure of transvenous lead extraction difficulty
    Ossama Elsaid
    David M. O’Sullivan
    Steven Zweibel
    Edmond M. Cronin
    Journal of Interventional Cardiac Electrophysiology, 2018, 53 : 383 - 389
  • [25] Clinical Experience with Afamelanotide for the Protoporphyrias in the United States
    Leaf, Rebecca Karp
    Elmariah, Sarina
    Jiang, Paul Yanning
    Mead, Jennifer
    Hodges, Pamela
    Valiante, Sarah Elizabeth
    Mernick, Francesca
    Anderson, Karl E.
    Dickey, Amy
    BLOOD, 2022, 140 : 2201 - 2202
  • [26] Coronary MRA: A clinical experience in the United States
    Danias, PG
    Stuber, M
    Edelman, RR
    Manning, WJ
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 1999, 10 (05) : 713 - 720
  • [27] Indications and outcome of laser lead extraction: a single centre experience
    Vergara, P.
    Mazzone, P.
    Sora, N.
    Marzi, A.
    Cuko, A.
    Paglino, G.
    Vicedomini, G.
    Santinelli, V.
    Pappone, C.
    EUROPEAN HEART JOURNAL, 2009, 30 : 416 - 416
  • [28] Optimal environment for pacemaker and implantable cardioverter-defibrillator lead extraction with a laser sheath
    Bracke, FA
    AMERICAN JOURNAL OF CARDIOLOGY, 1999, 83 (11): : 1594 - 1594
  • [29] Lead extraction using excimer laser sheath-In full swing even in Japan
    Imai, Katsuhiko
    JOURNAL OF CARDIOLOGY, 2013, 62 (3-4) : 201 - 202
  • [30] Associated factors and outcomes of crossover from a laser sheath to a bidirectional rotational mechanical sheath during transvenous lead extraction
    Isawa, Tsuyoshi
    Honda, Taku
    Yamaya, Kazuhiro
    Toyoda, Shigeru
    Taguri, Masataka
    JOURNAL OF ARRHYTHMIA, 2023, 39 (06) : 947 - 955