Impact of orthophosphate addition on biofilm development in drinking water distribution systems

被引:36
|
作者
Gouider, Mbarka [1 ]
Bouzid, Jalel [1 ]
Sayadi, Sami [2 ]
Montiel, Antoine [3 ]
机构
[1] Ecole Natl Ingn Sfax, Sfax, Tunisia
[2] Ctr Biotechnol Sfax, Lab Bioprocedes, Sfax, Tunisia
[3] Eau Paris, F-75014 Paris, France
关键词
Biofilm; Distribution network; Drinking water; Orthophosphate treatment; LEAD IMMOBILIZATION; HYDROXYAPATITE; DISINFECTION; PIPES;
D O I
10.1016/j.jhazmat.2009.01.128
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The contamination of the water distribution network results from fixed bacteria multiplication (biofilm) on the water pipe walls, followed by their detachment and their transport in the circulating liquid. The presence of biofilms in distribution networks can result in numerous unwanted problems for the user such as microbial contamination of the distributed water and deterioration of the network (bio-corrosion). For old networks, lead-containing plumbings can be a serious cause of worry for the consumer owing to the release of lead ions in the circulating water. Among the solutions considered to reduce the presence of lead in drinking water, the addition of orthophosphates constitutes an interesting alternative. However, the added orthophosphate may cause - even at low doses - additional microbial growth. The main objective of this study was to evaluate the impact of the orthophosphate treatment on the biofilm, development in the water supplied by the Joinville-le-Pont water treatment plant (Eau de Paris, France). For this purpose, a laboratory pilot plant was devised and connected to the considered water network. Two quantification methods for monitoring the biofilm formation were used: the enumeration on R2A agar and the determination of proteins. For the biofilm detachment operation, an optimization of the rinsing step was firstly conducted in order to distinguish between free and fixed biomass. The data obtained showed that there was a linear relation between both quantification methods. They also showed that, for the tested water, the bacterial densities were not affected by orthophosphate addition at a treatment rate of 1 mg PO43-/L. (C) 2009 Published by Elsevier B.V.
引用
下载
收藏
页码:1198 / 1202
页数:5
相关论文
共 50 条
  • [41] Effects of humic acid on residual Al control in drinking water treatment plants with orthophosphate addition
    Wendong Wang
    Hua Li
    Zhenzhen Ding
    Xiaochang Wang
    Rui Liu
    Frontiers of Environmental Science & Engineering, 2012, 6 : 470 - 476
  • [42] Effects of humic acid on residual Al control in drinking water treatment plants with orthophosphate addition
    Wang, Wendong
    Li, Hua
    Ding, Zhenzhen
    Wang, Xiaochang
    Liu, Rui
    FRONTIERS OF ENVIRONMENTAL SCIENCE & ENGINEERING, 2012, 6 (04) : 470 - 476
  • [43] Study on distribution and characteristics of the biofilm in the drinking-water biofilter
    Yu, J
    Zhang, C
    Zeng, GM
    Ren, WH
    ENERGY & ENVIRONMENT - A WORLD OF CHALLENGES AND OPPORTUNITIES, PROCEEDINGS, 2003, : 913 - 917
  • [44] Biofilms in Drinking Water Distribution Systems
    M. Batté
    B.M.R. Appenzeller
    D. Grandjean
    S. Fass
    V. Gauthier
    F. Jorand
    L. Mathieu
    M. Boualam
    S. Saby
    J.C. Block
    Reviews in Environmental Science and Biotechnology, 2003, 2 (2-4) : 147 - 168
  • [45] An overview of biofilm formation in distribution systems and its impact on the deterioration of water quality
    Momba, MNB
    Kfir, R
    Venter, SN
    Cloete, TE
    WATER SA, 2000, 26 (01) : 59 - 66
  • [46] Biofilm development in water distribution and drainage systems: dynamics and implications for hydraulic efficiency
    Cowle, M.W.
    Babatunde, A.O.
    Rauen, W.B.
    Bockelmann-Evans, B.N.
    Barton, A.F.
    Environmental Technology Reviews, 2014, 3 (01) : 31 - 47
  • [47] The Impact of Pipe Material on the Diversity of Microbial Communities in Drinking Water Distribution Systems
    Lee, Debbie
    Calendo, Gennaro
    Kopec, Kristin
    Henry, Rebekah
    Coutts, Scott
    McCarthy, David
    Murphy, Heather M.
    FRONTIERS IN MICROBIOLOGY, 2021, 12
  • [48] Impact of climate on pipe failure: Predictions of failures for drinking water distribution systems
    Wols B.A.
    van Thienen P.
    2016, TU Delft (16): : 240 - 253
  • [49] Biofilm bacterial communities in urban drinking water distribution systems transporting waters with different purification strategies
    Wu, Huiting
    Zhang, Jingxu
    Mi, Zilong
    Xie, Shuguang
    Chen, Chao
    Zhang, Xiaojian
    APPLIED MICROBIOLOGY AND BIOTECHNOLOGY, 2015, 99 (04) : 1947 - 1955
  • [50] Biofilm formation potential and chlorine resistance of typical bacteria isolated from drinking water distribution systems
    Zhu, Zebing
    Shan, Lili
    Hu, Fengping
    Li, Zehua
    Zhong, Dan
    Yuan, Yixing
    Zhang, Jie
    RSC ADVANCES, 2020, 10 (52) : 31295 - 31304