Impact of orthophosphate addition on biofilm development in drinking water distribution systems

被引:36
|
作者
Gouider, Mbarka [1 ]
Bouzid, Jalel [1 ]
Sayadi, Sami [2 ]
Montiel, Antoine [3 ]
机构
[1] Ecole Natl Ingn Sfax, Sfax, Tunisia
[2] Ctr Biotechnol Sfax, Lab Bioprocedes, Sfax, Tunisia
[3] Eau Paris, F-75014 Paris, France
关键词
Biofilm; Distribution network; Drinking water; Orthophosphate treatment; LEAD IMMOBILIZATION; HYDROXYAPATITE; DISINFECTION; PIPES;
D O I
10.1016/j.jhazmat.2009.01.128
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The contamination of the water distribution network results from fixed bacteria multiplication (biofilm) on the water pipe walls, followed by their detachment and their transport in the circulating liquid. The presence of biofilms in distribution networks can result in numerous unwanted problems for the user such as microbial contamination of the distributed water and deterioration of the network (bio-corrosion). For old networks, lead-containing plumbings can be a serious cause of worry for the consumer owing to the release of lead ions in the circulating water. Among the solutions considered to reduce the presence of lead in drinking water, the addition of orthophosphates constitutes an interesting alternative. However, the added orthophosphate may cause - even at low doses - additional microbial growth. The main objective of this study was to evaluate the impact of the orthophosphate treatment on the biofilm, development in the water supplied by the Joinville-le-Pont water treatment plant (Eau de Paris, France). For this purpose, a laboratory pilot plant was devised and connected to the considered water network. Two quantification methods for monitoring the biofilm formation were used: the enumeration on R2A agar and the determination of proteins. For the biofilm detachment operation, an optimization of the rinsing step was firstly conducted in order to distinguish between free and fixed biomass. The data obtained showed that there was a linear relation between both quantification methods. They also showed that, for the tested water, the bacterial densities were not affected by orthophosphate addition at a treatment rate of 1 mg PO43-/L. (C) 2009 Published by Elsevier B.V.
引用
下载
收藏
页码:1198 / 1202
页数:5
相关论文
共 50 条
  • [31] Impact of disinfection on drinking water biofilm bacterial community
    Zilong Mi
    Yu Dai
    Shuguang Xie
    Chao Chen
    Xiaojian Zhang
    Journal of Environmental Sciences, 2015, 37 (11) : 200 - 205
  • [32] Biofilm Formation in Water Distribution Systems
    Erdei-Tombor, Patricia
    Kisko, Gabriella
    Taczman-Bruckner, Andrea
    PROCESSES, 2024, 12 (02)
  • [33] Effect of sodium silicate on drinking water biofilm development
    Munoz, Sebastian
    Trueman, Benjamin F.
    Li, Bofu
    Gagnon, Graham A.
    ENVIRONMENTAL SCIENCE-WATER RESEARCH & TECHNOLOGY, 2022, 8 (06) : 1300 - 1311
  • [34] Impact of Zinc Orthophosphate on Simulated Drinking Water Biofilms Influenced by Lead and Copper
    Payne, Sarah Jane
    Piorkowski, Gregory S.
    Hansen, Lisbeth Truelstrup
    Gagnon, Graham A.
    JOURNAL OF ENVIRONMENTAL ENGINEERING, 2016, 142 (02)
  • [35] Nanogel-based coating as an alternative strategy for biofilm control in drinking water distribution systems
    Sojka, Olga
    Keskin, Damla
    van der Mei, Henny C.
    van Rijn, Patrick
    Gagliano, Maria Cristina
    BIOFOULING, 2023, 39 (02) : 121 - 134
  • [36] Biofilm Microbiome (Re)Growth Dynamics in Drinking Water Distribution Systems Are Impacted by Chlorine Concentration
    Fish, Katherine E.
    Boxall, Joby B.
    FRONTIERS IN MICROBIOLOGY, 2018, 9
  • [37] Biofilm control using chlorine-based disinfectants in model drinking water distribution systems
    Division of Environmental Science and Engineering, Faculty of Engineering, National University of Singapore, Singapore 119260, Singapore
    Water Sci. Technol. Water Supply, 2008, 5 (489-497):
  • [38] Microbiology, chemistry and biofilm development in a pilot drinking water distribution system with copper and plastic pipes
    Lehtola, MJ
    Miettinen, KT
    Keinänen, MM
    Kekki, TK
    Laine, O
    Hirvonen, A
    Vartiainen, T
    Martikainen, PJ
    WATER RESEARCH, 2004, 38 (17) : 3769 - 3779
  • [39] Detection of Helicobacter pylori by PCR but not culture in water and biofilm samples from drinking water distribution systems in England
    Watson, CL
    Owen, RJ
    Said, B
    Lai, S
    Lee, JV
    Surman-Lee, S
    Nichols, G
    JOURNAL OF APPLIED MICROBIOLOGY, 2004, 97 (04) : 690 - 698
  • [40] Dynamics of biofilm formation in a model drinking water distribution system
    Boe-Hansen, R
    Albrechtsen, HJ
    Arvin, E
    Jorgensen, C
    JOURNAL OF WATER SUPPLY RESEARCH AND TECHNOLOGY-AQUA, 2002, 51 (07): : 399 - 406