Retinal nerve fiber layer measurements in myopia: An optical coherence tomography study

被引:276
|
作者
Leung, Christopher Kai-Shun
Mohamed, Shaheeda
Leung, King Sai
Cheung, Carol Yim-Lui
Chan, Sylvia Lai-wa
Cheng, Daphne Ka-yee
Lee, August Ki-cheung
Leung, Gloria Yuk-oi
Rao, Srinivas Kamalakara
Lam, Dennis Shun Chiu
机构
[1] Chinese Univ Hong Kong, Dept Ophthalmol & Visual Sci, Hong Kong, Hong Kong, Peoples R China
[2] Caritas Med Ctr, Dept Ophthalmol, Hong Kong, Hong Kong, Peoples R China
关键词
D O I
10.1167/iovs.06-0545
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. To evaluate the relationship between retinal nerve fiber layer (RNFL) thickness measured by optical coherence tomography (OCT) and the axial length/refractive error of the eye. METHODS. A total of 115 eyes of 115 healthy subjects, comprising 75 eyes with high myopia (spherical equivalent [SE] < - 6.0 D) and 40 eyes with low to moderate myopia (SE between - 6.0 D and - 0.5D), were analyzed in this cross-sectional study. Total average and mean clock hour RNFL thicknesses were measured by OCT and compared between the two myopia groups. Associations between RNFL measurements and axial length and spherical equivalent were evaluated by linear regression analysis. RESULTS. The RNFL measurements were significantly lower in the high myopia group compared with those of the low-tomoderate myopia group at 12, 1, and 7 o'clock (right eye orientation). Apart from the temporal clock hours, significant correlations were evident between RNFL measurements and the axial length and spherical equivalent. The average RNFL thickness decreased with increasing axial length (r = -0.314, P = 0.001) and negative refractive power (r = 0.291, P = 0.002). A significant proportion of myopic eyes were classified as outside normal limits, with reference to the normative database. The most frequently abnormal sector was at 2 o'clock, where 16.5% of myopic eyes were outside normal limits. CONCLUSIONS. RNFL measurements vary with the axial length/refractive error of the eye. Analysis of RNFL thickness in the evaluation of glaucoma should always be interpreted with reference to the refractive status. Although the normative database provided by OCT has been helpful in identifying ocular diseases involving the RNFL, it may not be reliable in the analysis of myopic eyes.
引用
收藏
页码:5171 / 5176
页数:6
相关论文
共 50 条
  • [41] Optical coherence tomography measurements of retinal nerve fiber layer thickness in amblyopic and non-amblyopic eyes
    Rabbione, MM
    Roagna, B
    Tonetti, S
    Morgese, A
    Rolle, T
    Musso, M
    Grignolo, FM
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 : U964 - U964
  • [42] Reproducibility of Circumpapillary Retinal Nerve Fiber Layer Measurements Using Handheld Optical Coherence Tomography in Sedated Children
    Avery, Robert A.
    Cnaan, Avital
    Schuman, Joel S.
    Chen, Chieh-Li
    Glaug, Natalie C.
    Packer, Roger J.
    Quinn, Graham E.
    Ishikawa, Hiroshi
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2014, 158 (04) : 780 - 787
  • [43] The Influence of Optical Coherence Tomography Measurements of Retinal Nerve Fiber Layer on Decision-Making in Glaucoma Diagnosis
    Fu, Lanxing
    Aspinall, Peter
    Bennett, Gary
    Magidson, Jay
    Tatham, Andrew J.
    [J]. CURRENT EYE RESEARCH, 2017, 42 (04) : 575 - 582
  • [44] Retinal Nerve Fiber Layer Thickness in Dominant Optic Atrophy Measurements by Optical Coherence Tomography and Correlation with Age
    Barboni, Piero
    Savini, Giacomo
    Parisi, Vincenzo
    Carbonelli, Michele
    La Morgia, Chiara
    Maresca, Alessandra
    Sadun, Federico
    De Negri, Anna Maria
    Carta, Arturo
    Sadun, Alfredo A.
    Carelli, Valerio
    [J]. OPHTHALMOLOGY, 2011, 118 (10) : 2076 - 2080
  • [45] Variations in retinal nerve fiber layer measurements on optical coherence tomography after implantation of trifocal intraocular lens
    Garcia-Bella, Javier
    Martinez de la Casa, Jose M.
    Talavero Gonzalez, Paula
    Fernandez-Vigo, Jose I.
    Valcarce Rial, Laura
    Garcia-Feijoo, Julian
    [J]. EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2018, 28 (01) : 32 - 35
  • [46] Retinal Nerve Fiber Layer Volume Measurements in Normal Children Using Spectral Domain Optical Coherence Tomography
    Lee, Dong Eik
    Shin, Joong Won
    Lim, Han Woong
    Shin, Yong Un
    Kang, Min Ho
    Cho, Hee Yoon
    Seong, Min Cheol
    [J]. JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2016, 57 (05): : 800 - 807
  • [47] Author Response: Retinal Nerve Fiber Layer Thickness Measurements in Rats with the Spectral Domain Optical Coherence Tomography
    Lange, Katharina
    Baehr, Mathias
    Hein, Katharina
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2012, 53 (07) : 3570 - 3571
  • [48] Comparison of Time Domain and Spectral Domain Optical Coherence Tomography in Retinal Nerve Fiber Layer Thickness Measurements
    Bhartiya, S.
    Kumar, M.
    Kumar, V.
    Khanduja, S.
    Mishra, S. K.
    Dada, T.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [49] Reproducibility of Retinal Nerve Fiber Layer and Macular Thickness Measurements Using Spectral Domain Optical Coherence Tomography
    Sood, Amit
    Paliwal, Rahul Omprakash
    Mishra, Rishu Yogesh
    [J]. GALICIAN MEDICAL JOURNAL, 2021, 28 (04)
  • [50] Optical coherence tomography (OCT) macular and peripapillary retinal nerve fiber layer measurements and automated visual fields
    Wollstein, G
    Schuman, JS
    Price, LL
    Aydin, A
    Beaton, SA
    Stark, PC
    Fujimoto, JG
    Ishikawa, H
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2004, 138 (02) : 218 - 225