Fluoroscopic-Guided Lumbar Puncture: Fluoroscopic Time and Implications of Body Mass Index-A Baseline Study

被引:20
|
作者
Boddu, S. R. [1 ]
Corey, A. [1 ]
Peterson, R. [1 ]
Saindane, A. M. [1 ]
Hudgins, P. A. [1 ]
Chen, Z. [3 ]
Wang, X. [3 ]
Applegate, K. E. [2 ]
机构
[1] Emory Univ Hosp, Div Neuroradiol, Dept Radiol & Imaging Sci, Atlanta, GA 30322 USA
[2] Emory Univ Hosp, Div Pediat Radiol, Dept Radiol & Imaging Sci, Atlanta, GA 30322 USA
[3] Emory Univ, Dept Biostat & Bioinformat, Atlanta, GA 30322 USA
关键词
RADIATION-EXPOSURE; UNITED-STATES; OBESITY;
D O I
10.3174/ajnr.A3914
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE Fluoroscopic-guided lumbar puncture is an effective alternative to bedside lumbar puncture in challenging patients. However, no published guidelines are available for an acceptable range of fluoroscopic time for this procedure. The purpose of this study was to set department benchmark fluoroscopic times for lumbar puncture, accounting for body mass index in our patient population. MATERIALS AND METHODS: We identified and reviewed all patients who underwent fluoroscopic-guided lumbar puncture at 4 hospitals during a 2-year period (July 2011 to June 2013). Data collection included patient information (demographics, body mass index, history of prior lumbar surgery and/or lumbar hardware, scoliosis); procedure details (fluoroscopic time, level of access, approach, needle gauge and length); level of operator experience; and hospital site. A generalized linear model was used to test whether body mass index influenced fluoroscopic time while controlling other factors. RESULTS: Five hundred eighty-four patients (mean age, 47.8 16.2 years; range, 16-92 years; 33% male) had successful fluoroscopic-guided lumbar puncture s. Mean body mass index and fluoroscopic time were higher in female patients (34.4 +/- 9.9 kg/m(2) and 1.07 minutes; 95% CI, 0.95-1.20) than in male patients (29.2 +/- 7.3 kg/m(2) and 0.91 minutes; 95% CI, 0.79-1.03). Body mass index (P=.001), hospital site (P<.001), and level of experience (P=.03) were factors significantly affecting fluoroscopic time on multivariate analysis. Benchmark fluoroscopic times in minutes were the following: 0.48(95% CI, 0.40-0.56) for normal, 0.61 for overweight (95% CI, 0.52-0.71), 0.63(95% CI, 0.58-0.73) for obese, and 0.86 (95% CI, 0.74-1.01) in extremely obese body mass index categories. CONCLUSIONS: In patients undergoing fluoroscopic-guided lumbar punctures, fluoroscopy time increased with body mass index We established benchmark fluoroscopic-guided lumbar puncture time ranges as related to body mass index in our patient population.
引用
收藏
页码:1475 / 1480
页数:6
相关论文
共 50 条
  • [41] A Study to Compare Operator Dosimeter Exposure Versus Fluoroscopic Time and Air Kerma in Fluoroscopically Guided Interventional Procedures
    McKetty, M.
    MEDICAL PHYSICS, 2012, 39 (06) : 3633 - 3633
  • [42] Equivalent radiation exposure with robotic total hip replacement using a novel, fluoroscopic-guided (CT-free) system: case–control study versus manual technique
    Graham Buchan
    Christian Ong
    Christian Hecht
    Thomas J. Tanous
    Blake Peterson
    Akihiko Hasegawa
    Atul F. Kamath
    Journal of Robotic Surgery, 2023, 17 : 1561 - 1567
  • [43] Using Body Mass Index to Predict Needle Length in Fluoroscopy-Guided Lumbar Punctures
    Nayate, A. P.
    Nasrallah, I. M.
    Schmitt, J. E.
    Mohan, S.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2016, 37 (03) : 572 - 578
  • [44] The importance of sex, age, needle size, height and body mass index in post-lumbar puncture headache
    Vilming, ST
    Kloster, R
    Sandvik, L
    CEPHALALGIA, 2001, 21 (07) : 738 - 743
  • [45] Correction to: Equivalent radiation exposure with robotic total hip replacement using a novel, fluoroscopic-guided (CT-free) system: case–control study versus manual technique
    Graham Buchan
    Christian Ong
    Christian Hecht
    Thomas J. Tanous
    Blake Peterson
    Masahiro Hasegawa
    Atul F. Kamath
    Journal of Robotic Surgery, 2023, 17 : 1569 - 1569
  • [46] The impact of body mass index on fluoroscopy time during lumbar epidural steroid injection: a multicenter cohort study
    Choxi, S.
    McCormick, Z.
    Cushman, D.
    Walega, D.
    Lee, D.
    Marcolina, A.
    Press, J.
    Kennedy, D.
    Smuck, M.
    JOURNAL OF PAIN, 2016, 17 (04): : S90 - S91
  • [47] The Impact of Body Mass Index on Fluoroscopy Time During Lumbar Epidural Steroid Injection; A Multicenter Cohort Study
    McCormick, Zachary L.
    Choxi, Sarah C.
    Lee, David T.
    Marcolina, Austin
    Press, Joel
    Kennedy, D. J.
    Smuck, Matthew
    Walega, David R.
    Cushman, Daniel M.
    PAIN MEDICINE, 2017, 18 (01) : 25 - 35
  • [48] Body Mass Index and Risk for Clinical Lumbar Spinal Stenosis A Cohort Study
    Knutsson, Bjorn
    Sanden, Bengt
    Sjoden, Goran
    Jarvholm, Bengt
    Michaelsson, Karl
    SPINE, 2015, 40 (18) : 1451 - 1456
  • [49] Safety and Accuracy of Anatomic and Lateral Fluoroscopic-Guided Placement of C2 Pars/Pedicle Screws and C1 Lateral Mass Screws, and Freehand Placement of C2 Laminar Screws
    Kiran, Narayanam Anantha Sai
    Sivaraju, Laxminadh
    Vidyasagar, Kanneganti
    Aryan, Sarita
    Raj, Vivek
    Rajagopal, Niranjana
    Mohan, Dilip
    Thakar, Sumit
    Rao, Arun Sadashiva
    Hegde, Alangar S.
    WORLD NEUROSURGERY, 2018, 118 : E304 - E315
  • [50] The impact of baseline body mass index on clinical outcomes in metastatic breast cancer: A prospective study
    Alarfi H.
    Salamoon M.
    Kadri M.
    Alammar M.
    Haykal M.A.
    Alseoudi A.
    Youssef L.A.
    BMC Research Notes, 10 (1)