Equivalent radiation exposure with robotic total hip replacement using a novel, fluoroscopic-guided (CT-free) system: case–control study versus manual technique

被引:0
|
作者
Graham Buchan
Christian Ong
Christian Hecht
Thomas J. Tanous
Blake Peterson
Akihiko Hasegawa
Atul F. Kamath
机构
[1] Cleveland Clinic Foundation,Department of Orthopaedic Surgery
[2] Advanced Orthopaedics and Sports Medicine a Division of OrthoLoneStar,Department of Orthopaedic Surgery
[3] Orthopedic and Sports Medicine Center of St. Joseph,undefined
[4] Mie University Graduate School of Medicine,undefined
来源
关键词
Total hip arthroplasty (THA); Robotic surgery; Radiation; Fluoroscopy; Robot assisted;
D O I
暂无
中图分类号
学科分类号
摘要
Accurate and precise positioning of the acetabular cup remains a prevalent challenge in total hip arthroplasty (THA). Robotic assistance for THA has increased over the past decade due to the potential to improve the accuracy of implant placement. However, a common criticism of existing robotic systems is the requirement for preoperative computerized tomography (CT) scans. This additional imaging increases patient radiation exposure, as well as cost, and requires pin placement during surgery. The goal of this study was to analyze the radiation burden associated with a novel, CT-free robotic THA system compared to an unassisted manual THA approach (n = 100/arm). On average, the study cohort had a higher number of fluoroscopic images captured (7.5 vs. 4.3 images; p < 0.001), radiation dose (3.0 vs. 1.0 mGy; p < 0.001), and a longer duration of radiation exposure (18.8 vs. 6.3 s; p < 0.001), per procedure, than the control group. Additionally, no learning curve was detected by CUSUM analysis with respect to the number of fluoroscopic images taken during the adoption of the robotic THA system. While statistically significant, in comparison to published literature, the radiation exposure of the CT-free robotic THA system was comparable to that of unassisted manual THA approach and less than that of CT-based robotic approaches. Thus, the novel CT-free robotic system likely poses no clinically significant increase in radiation exposure to the patient compared to manual approaches.
引用
收藏
页码:1561 / 1567
页数:6
相关论文
共 10 条
  • [1] Correction to: Equivalent radiation exposure with robotic total hip replacement using a novel, fluoroscopic-guided (CT-free) system: case–control study versus manual technique
    Graham Buchan
    Christian Ong
    Christian Hecht
    Thomas J. Tanous
    Blake Peterson
    Masahiro Hasegawa
    Atul F. Kamath
    Journal of Robotic Surgery, 2023, 17 : 1569 - 1569
  • [2] Equivalent radiation exposure with robotic total hip replacement using a novel, fluoroscopic-guided (CT-free) system: case-control study versus manual technique (Mar 2023, 10.1007/s11701-023-01554-6)
    Buchan, Graham
    Ong, Christian
    Hecht, Christian
    Tanous, Thomas J.
    Peterson, Blake
    Hasegawa, Masahiro
    Kamath, Atul F.
    JOURNAL OF ROBOTIC SURGERY, 2023, 17 (04) : 1569 - 1569
  • [3] Robotic-assisted versus manual total hip arthroplasty in obese patients: a retrospective case–control study
    Shuai Zhang
    Yubo Liu
    Minzhi Yang
    Mingyang Ma
    Zheng Cao
    Xiangpeng Kong
    Wei Chai
    Journal of Orthopaedic Surgery and Research, 17
  • [4] Robotic-assisted versus manual total hip arthroplasty in obese patients: a retrospective case-control study
    Zhang, Shuai
    Liu, Yubo
    Yang, Minzhi
    Ma, Mingyang
    Cao, Zheng
    Kong, Xiangpeng
    Chai, Wei
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2022, 17 (01)
  • [5] Improved short-term outcomes for a novel, fluoroscopy-based robotic-assisted total hip arthroplasty system compared to manual technique with fluoroscopic assistance
    Buchan, Graham B. J.
    Hecht II, Christian J.
    Sculco, Peter K.
    Chen, James B.
    Kamath, Atul F.
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2024, 144 (01) : 501 - 508
  • [6] Improved short-term outcomes for a novel, fluoroscopy-based robotic-assisted total hip arthroplasty system compared to manual technique with fluoroscopic assistance
    Graham B. J. Buchan
    Christian J. Hecht
    Peter K. Sculco
    James B. Chen
    Atul F. Kamath
    Archives of Orthopaedic and Trauma Surgery, 2024, 144 : 501 - 508
  • [7] Direct anterior approach with conventional instruments versus robotic posterolateral approach in elective total hip replacement for primary osteoarthritis: a case–control study
    Mattia Alessio-Mazzola
    Pietro Colombo
    Niccolo’ Barducci
    Elena Ghezzi
    Luigi Zagra
    Patrizio Caldora
    Marco Ometti
    Giacomo Placella
    Vincenzo Salini
    Journal of Orthopaedics and Traumatology, 25
  • [8] Direct anterior approach with conventional instruments versus robotic posterolateral approach in elective total hip replacement for primary osteoarthritis: a case-control study
    Alessio-Mazzola, Mattia
    Colombo, Pietro
    Barducci, Niccolo'
    Ghezzi, Elena
    Zagra, Luigi
    Caldora, Patrizio
    Ometti, Marco
    Placella, Giacomo
    Salini, Vincenzo
    JOURNAL OF ORTHOPAEDICS AND TRAUMATOLOGY, 2024, 25 (01)
  • [9] Use of a novel imageless navigation system reduced fluoroscopy exposure and improved acetabular positioning in anterior approach total hip arthroplasty: a case–control study
    Christian B. Ong
    Yu-Fen Chiu
    Ajay Premkumar
    Alejandro Gonzalez Della Valle
    Archives of Orthopaedic and Trauma Surgery, 2023, 143 : 2739 - 2745
  • [10] Use of a novel imageless navigation system reduced fluoroscopy exposure and improved acetabular positioning in anterior approach total hip arthroplasty: a case-control study
    Ong, Christian B.
    Chiu, Yu-Fen
    Premkumar, Ajay
    Gonzalez Della Valle, Alejandro
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2023, 143 (05) : 2739 - 2745