Improved short-term outcomes for a novel, fluoroscopy-based robotic-assisted total hip arthroplasty system compared to manual technique with fluoroscopic assistance

被引:4
|
作者
Buchan, Graham B. J. [1 ]
Hecht II, Christian J. [1 ]
Sculco, Peter K. [2 ]
Chen, James B. [3 ]
Kamath, Atul F. [1 ]
机构
[1] Cleveland Clin Fdn, Orthopaed & Rheumatol Inst, Dept Orthopaed Surg, 9500 Euclid Ave, Cleveland, OH 44195 USA
[2] Hosp Special Surg, Dept Orthopaed Surg, 535 East 70th, New York, NY 10021 USA
[3] Providence Mission Hosp, Mission Orthopaed Inst, Mission Viejo, CA 92691 USA
关键词
Total hip arthroplasty (THA); Outcomes; Robotic-assisted surgery; Fluoroscopy; Robotic THA; Hip replacement; ACETABULAR COMPONENT; ORIENTATION; SURGERY;
D O I
10.1007/s00402-023-05061-z
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background While robotic-assisted total hip arthroplasty (RA-THA) has been associated with improved accuracy of component placement, the perioperative and early postoperative outcomes of fluoroscopy-based RA-THA systems have yet to be elucidated.Methods This retrospective cohort analysis included a consecutive series of patients who received manual, fluoroscopy-assisted THA (mTHA) and fluoroscopy-based RA-THA at a single institution. We compared rates of complications within 90 days of surgery, length of hospital stay (LOS), and visual analog scale (VAS) pain scores.Results No differences existed between groups with respect to demographic data or perioperative recovery protocols. The RA-THA cohort had a significantly greater proportion of outpatient surgeries compared to the mTHA cohort (37.4% vs. 3.8%; p < 0.001) and significantly lower LOS (26.0 vs. 39.5 h; p < 0.001). The RA-THA cohort had a smaller 90-day postoperative complication rate compared to the mTHA cohort (0.9% vs. 6.7%; p = 0.029). The RA-THA cohort had significantly lower patient-reported VAS pain scores at 2-week follow-up visits (2.5 vs. 3.3; p = 0.048), but no difference was seen after 6-week follow visits (2.5 vs. 2.8; p = 0.468).Conclusion Fluoroscopy-based RA-THA demonstrates low rates of postoperative complications, improved postoperative pain profiles, and shortened LOS when compared to manual, fluoroscopy-assisted THA.
引用
收藏
页码:501 / 508
页数:8
相关论文
共 50 条
  • [1] Improved short-term outcomes for a novel, fluoroscopy-based robotic-assisted total hip arthroplasty system compared to manual technique with fluoroscopic assistance
    Graham B. J. Buchan
    Christian J. Hecht
    Peter K. Sculco
    James B. Chen
    Atul F. Kamath
    Archives of Orthopaedic and Trauma Surgery, 2024, 144 : 501 - 508
  • [2] The learning curve for a novel, fluoroscopy-based robotic-assisted total hip arthroplasty system
    Buchan, Graham B. J.
    Hecht II, Christian J. J.
    Lawrie, Charles M.
    Sculco, Peter K.
    Kamath, Atul F.
    INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2023, 19 (04):
  • [3] Use of a fluoroscopy-based robotic-assisted total hip arthroplasty system produced greater improvements in patient-reported outcomes at one year compared to manual, fluoroscopic-assisted technique
    Graham B.J. Buchan
    Christian B. Ong
    Christian J. Hecht II
    Charles A. DeCook
    Luke S. Spencer-Gardner
    Atul F. Kamath
    Archives of Orthopaedic and Trauma Surgery, 2024, 144 : 1843 - 1850
  • [4] Use of a fluoroscopy-based robotic-assisted total hip arthroplasty system produced greater improvements in patient-reported outcomes at one year compared to manual, fluoroscopic-assisted technique
    Buchan, Graham B. J.
    Ong, Christian B.
    Hecht, Christian J.
    Decook, Charles A.
    Spencer-Gardner, Luke S.
    Kamath, Atul F.
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2024, 144 (04) : 1843 - 1850
  • [5] Fluoroscopy-based robotic assistance for total hip arthroplasty improves acetabular cup placement accuracy for obese patients compared to the manual, fluoroscopic-assisted technique
    Ong, Christian B.
    Buchan, Graham B. J.
    Hecht II, Christian J.
    Kendoff, Daniel O.
    Homma, Yasuhiro
    Kamath, Atul F.
    TECHNOLOGY AND HEALTH CARE, 2024, 32 (05) : 3703 - 3712
  • [6] Efficacy of a novel, fluoroscopy-based robotic-assisted total hip arthroplasty system in restoring limb length and offset
    Buchan, Graham B. J.
    Hecht, Christian J.
    Nugent, Mary
    Heckmann, Nathanael D.
    Kanaji, Arihiko
    Kamath, Atul F.
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2025, 145 (01)
  • [7] Cost-effectiveness of a novel, fluoroscopy-based robotic-assisted total hip arthroplasty system: A Markov analysis
    Ong, Christian B.
    Buchan, Graham B. J.
    Acuna, Alexander J.
    Hecht, Christian J.
    Homma, Yasuhiro
    Shah, Roshan P.
    Kamath, Atul F.
    INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2024, 20 (01):
  • [8] Fluoroscopy-based robotics in total hip arthroplasty mitigates laterality-based differences in acetabular cup placement when compared to the manual, fluoroscopic-assisted technique
    Ong, Christian B.
    Buchan, Graham B. J.
    Hecht, Christian J.
    Homma, Yasuhiro
    Harmon, Daniel J.
    Kendoff, Daniel O.
    Petterwood, Joshua
    Kamath, Atul F.
    TECHNOLOGY AND HEALTH CARE, 2024, 32 (05) : 3693 - 3701
  • [9] Use of a fluoroscopy-based robotic-assisted total hip arthroplasty system resulted in greater improvements in hip-specific outcome measures at one-year compared to a CT-based robotic-assisted system
    Ong, Christian B.
    Buchan, Graham B. J.
    Hecht, Christian J., II
    Liu, David
    Petterwood, Joshua
    Kamath, Atul F.
    INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2024, 20 (03):
  • [10] Improved accuracy of a novel fluoroscopy-based robotically assisted THA system compared to manual THA
    Buchan, Graham B. J.
    Hecht, Christian J.
    Liu, David
    Mokete, Lipalo
    Kendoff, Daniel
    Kamath, Atul F.
    JOURNAL OF ROBOTIC SURGERY, 2023, 17 (05) : 2073 - 2079