Route to higher fidelity FT-IR imaging

被引:34
|
作者
Bhargava, R [1 ]
Wang, SQ [1 ]
Koenig, JL [1 ]
机构
[1] Case Western Reserve Univ, Dept Macromol Sci, Cleveland, OH 44106 USA
关键词
Fourier transform infrared microspectroscopy; imaging; minimum noise fraction; principal components; signal-to-noise ratio; morphological analysis; polymer dispersed liquid crystals;
D O I
10.1366/0003702001949898
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
FT-IR imaging employing a focal plane array (FPA) detector is often plagued by low signal-to-noise ratio (SNR) data. A mathematical transform that re-orders spectral data points into decreasing order of SNR is employed to reduce noise by retransforming the ordered data set using only a few relevant data points, This approach is shown to result in significant gains in terms of image fidelity by examining microscopically phase-separated composites termed polymer dispersed liquid crystals (PDLCs). The actual gains depend on the SNR characteristics of the original data. Noise is reduced by a factor greater than 5 if the noise in the initial data is sufficiently low. For a moderate absorbance level of 0.5 a.u., the achievable SNR by reducing noise is greater than 100 for a collection time of less than 3 min. The criteria for optimal application of a noise-reducing procedure employing the minimum noise fraction (MNF) transform are discussed and various variables in the process quantified. This noise reduction is shown to provide high-quality images for accurate morphological analysis. The coupling of mathematical transformation techniques with spectroscopic Fourier transform infrared (FT-IR) imaging is shown to result in high-fidelity images without increasing collection time or drastically modifying hardware.
引用
收藏
页码:486 / 495
页数:10
相关论文
共 50 条
  • [1] Considerations in Choosing an FT-IR IMAGING SYSTEM FT-IR IMAGING IS A POWERFUL TOOL FOR MATERIALS CHARACTERIZATION
    Materials Characterization Business, PerkinElmer Life and Analytical Sciences, Seer Green, United Kingdom
    Lab. Manager., 2008, 1 (27-29):
  • [2] 'Breakthrough' FT-IR imaging system
    不详
    HYDROCARBON PROCESSING, 2001, 80 (11): : 31 - 31
  • [3] The imaging advantage to FT-IR spectroscopy
    Leary, Pauline E.
    Giordano, Jennifer L.
    Reffner, John A.
    SPECTROSCOPY, 2008, : 12 - +
  • [4] FT-IR imaging of polymers: an industrial appraisal
    Chalmers, JM
    Everall, NJ
    Schaeberle, MD
    Levin, IW
    Lewis, EN
    Kidder, LH
    Wilson, J
    Crocombe, R
    VIBRATIONAL SPECTROSCOPY, 2002, 30 (01) : 43 - 52
  • [5] Fast FT-IR imaging: Theory and applications
    Koenig, JL
    Snively, CM
    SPECTROSCOPY, 1998, 13 (11) : 22 - 28
  • [6] Characterization of cotton and treated cotton by FT-IR and FT-IR microspectroscopy
    Morris, NM
    Catalano, EA
    Morris, CE
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1997, 213 : 45 - CELL
  • [7] A COMPARISON OF FT-IR/PA AND FT-IR/PBD SPECTRA OF POWDERS
    VARLASHKIN, PG
    LOW, MJD
    PARODI, GA
    MORTERRA, C
    APPLIED SPECTROSCOPY, 1986, 40 (05) : 636 - 641
  • [8] Integrated FT-IR and Raman imaging on the same microscope
    Adar, Fran
    Whitley, Andrew
    Lee, Eunah
    LeBourdon, Gwen
    SPECTROSCOPY, 2008, : 27 - 30
  • [9] FT-IR microspectroscopic imaging of prostate tissue sections
    Lasch, P
    Diem, M
    Naumann, D
    BIOMEDICAL VIBRATIONAL SPECTROSCOPY AND BIOHAZARD DETECTION TECHNOLOGIES, 2004, 5321 : 1 - 9
  • [10] Towards faster FT-IR imaging by reducing noise
    Bhargava, R
    Ribar, T
    Koenig, JL
    APPLIED SPECTROSCOPY, 1999, 53 (11) : 1313 - 1322