Route to higher fidelity FT-IR imaging

被引:34
|
作者
Bhargava, R [1 ]
Wang, SQ [1 ]
Koenig, JL [1 ]
机构
[1] Case Western Reserve Univ, Dept Macromol Sci, Cleveland, OH 44106 USA
关键词
Fourier transform infrared microspectroscopy; imaging; minimum noise fraction; principal components; signal-to-noise ratio; morphological analysis; polymer dispersed liquid crystals;
D O I
10.1366/0003702001949898
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
FT-IR imaging employing a focal plane array (FPA) detector is often plagued by low signal-to-noise ratio (SNR) data. A mathematical transform that re-orders spectral data points into decreasing order of SNR is employed to reduce noise by retransforming the ordered data set using only a few relevant data points, This approach is shown to result in significant gains in terms of image fidelity by examining microscopically phase-separated composites termed polymer dispersed liquid crystals (PDLCs). The actual gains depend on the SNR characteristics of the original data. Noise is reduced by a factor greater than 5 if the noise in the initial data is sufficiently low. For a moderate absorbance level of 0.5 a.u., the achievable SNR by reducing noise is greater than 100 for a collection time of less than 3 min. The criteria for optimal application of a noise-reducing procedure employing the minimum noise fraction (MNF) transform are discussed and various variables in the process quantified. This noise reduction is shown to provide high-quality images for accurate morphological analysis. The coupling of mathematical transformation techniques with spectroscopic Fourier transform infrared (FT-IR) imaging is shown to result in high-fidelity images without increasing collection time or drastically modifying hardware.
引用
收藏
页码:486 / 495
页数:10
相关论文
共 50 条
  • [11] FT-IR imaging system cuts analysis time
    不详
    PLASTICS ENGINEERING, 2002, 58 (02) : 34 - 34
  • [12] Characterizing the performance of a fast FT-IR imaging spectrometer
    Case Western Reserve Univ, Cleveland, United States
    Appl Spectrosc, 2 (170-177):
  • [13] Processing FT-IR imaging data for morphology visualization
    Bhargava, R
    Wang, SQ
    Koenig, JL
    APPLIED SPECTROSCOPY, 2000, 54 (11) : 1690 - 1706
  • [14] FT-IR spectroscopic imaging of tissue thin sections
    Lasch, P
    Boese, M
    Diem, M
    DIAGNOSTIC OPTICAL SPECTROSCOPY IN BIOMEDICINE, 2001, 4432 : 10 - 16
  • [15] Characterizing the performance of a fast FT-IR imaging spectrometer
    Snively, CM
    Koenig, JL
    APPLIED SPECTROSCOPY, 1999, 53 (02) : 170 - 177
  • [16] UPDATE ON FT-IR
    GRIFFITHS, PR
    APPLIED SPECTROSCOPY, 1992, 46 (11) : A14 - A15
  • [17] APPLICATIONS OF FT-IR
    GRIFFITHS, PR
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1987, 193 : 108 - CHED
  • [18] LETS DROP THE FT IN FT-IR
    MILLER, FA
    APPLIED SPECTROSCOPY, 1988, 42 (05) : A12 - A12
  • [19] COMPARISON OF FT-IR/PA AND FT-IR/PBD SPECTRA OF POWDERS.
    Varlashkin, P.G.
    Low, M.J.D.
    Parodi, G.A.
    Morterra, C.
    1600, (40):
  • [20] ONLINE HPLC FT-IR AND SFC FT-IR WITH SUBMICROGRAM DETECTION LIMITS
    GRIFFITHS, PR
    CONROY, CM
    SHAFER, KH
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1984, 188 (AUG): : 35 - ANYL