Ex Vivo Evaluation of the Accuracy of 3 Electronic Apex Locators in Different Environments: A Micro-Computed Tomography Study

被引:3
|
作者
Cinar, Firdevs [1 ]
Ustun, Yakup [2 ]
机构
[1] Ortoperio Dent Clin, Endodont, Kayseri, Turkey
[2] Erciyes Univ, Fac Dent, Dept Endodont, Kayseri, Turkey
来源
EUROPEAN ENDODONTIC JOURNAL | 2020年 / 5卷 / 03期
关键词
mini Root ZX; NaOCl; Propex pixi; Raypex; 5; ROOT-CANAL MORPHOLOGY; LENGTH DETERMINATION; SODIUM-HYPOCHLORITE; FILE SIZE; FORAMEN; CONSTRICTION; MOLARS; TEETH;
D O I
10.14744/eej.2020.30633
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective: The aim of this study was to compare the accuracy of three electronic apex locators (EALs) (Propex Pixi, Mini Root ZX, Raypex 5) in determining working length (WL) under different environments (existence of blood-pulp/sodium hypochlorite in root canal space) using micro-computed tomography (micro-CT) measurements. Methods: Twenty-five single-rooted human teeth that were scheduled for extraction were selected for the study. Measurements were performed with the Propex Pixi, Mini Root ZX, Raypex 5 in vivo conditions in the presence of NaOCl irrigant solution or blood-pulp tissue. After that the teeth were extracted and scanned using micro- CT. The measurements of WL obtained with the different EALs in different environments were statistically compared. Significance was set at P<0.05. Results: There were no significant differences among the WL measurements performed with EALs or micro CT groups under different clinical enviroments. All EALs tested gave reliable results in respect to apical constriction. Conclusion: The accuracy of the tested EALs is not affected by pulp tissues and blood or NaOCl.
引用
收藏
页码:226 / 230
页数:5
相关论文
共 50 条
  • [31] In Vivo Evaluation of 3 Electronic Apex Locators: Root ZX Mini, Apex ID, and Propex Pixi
    Serna-Pena, Gabriela
    Gomes-Azevedo, Susana
    Flores-Trevino, Jorge
    Madla-Cruz, Elizabeth
    Rodriguez-Delgado, Idalia
    Martinez-Gonzalez, Gustavo
    JOURNAL OF ENDODONTICS, 2020, 46 (02) : 158 - 161
  • [32] Comparisons of the diagnostic accuracies of optical coherence tomography, micro-computed tomography, and histology in periodontal disease: an ex vivo study
    Park, Jin-Young
    Chung, Jung-Ho
    Lee, Jung-Seok
    Kim, Hee-Jin
    Choi, Seong-Ho
    Jung, Ui-Won
    JOURNAL OF PERIODONTAL AND IMPLANT SCIENCE, 2017, 47 (01): : 30 - 40
  • [33] In Vitro Comparison of the Accuracy of Cone-Beam Computed Tomography Scanning and Electronic Apex Locators in Detection of Simulated Root Perforations in Different Localizations
    Harorli, Hatice
    Koc, Simay
    Kustarci, Alper
    JOURNAL OF ENDODONTICS, 2023, 49 (12) : 1676 - 1681
  • [34] Ex vivo micro-computed tomography analysis of bleomycin-induced lung fibrosis for preclinical drug evaluation
    Scotton, Chris J.
    Hayes, Brian
    Alexander, Robert
    Datta, Arnab
    Forty, Ellen J.
    Mercer, Paul F.
    Blanchard, Andy
    Chambers, Rachel C.
    EUROPEAN RESPIRATORY JOURNAL, 2013, 42 (06) : 1633 - 1645
  • [35] Evaluation of shaping ability of different glide path instruments: a micro-computed tomography study
    Merve Yeniçeri Özata
    Seda Falakaloğlu
    Ali Keleş
    Özkan Adıgüzel
    Mustafa Gündoğar
    BMC Oral Health, 23
  • [36] Evaluation of shaping ability of different glide path instruments: a micro-computed tomography study
    Ozata, Merve Yeniceri
    Falakaloglu, Seda
    Keles, Ali
    Adiguzel, Oezkan
    Gundogar, Mustafa
    BMC ORAL HEALTH, 2023, 23 (01)
  • [37] Ex Vivo Evaluation of the Accuracy of Electronic Foramen Locators in Root Canals with an Obstructed Apical Foramen
    de Vasconcelos, Bruno Carvalho
    Verissimo Chaves, Rebeca Dibe
    Vivacqua-Gomes, Nilton
    de Miranda Candeiro, George Taccio
    Bernardes, Ricardo Affonso
    Vivan, Rodrigi Ricci
    Hungaro Duarte, Marco Antonio
    JOURNAL OF ENDODONTICS, 2015, 41 (09) : 1551 - 1554
  • [38] Comparative evaluation of accuracy of two electronic apex locators in the presence of various irrigants: An in vitro study
    Jain, Saru
    Kapur, Ravi
    CONTEMPORARY CLINICAL DENTISTRY, 2012, 3 (06) : 140 - 145
  • [39] Dentine thickness in maxillary fused molars depends on the fusion type: An ex vivo micro-computed tomography study
    Keskin, Canguel
    Toplu, Defne
    Keles, Ali
    INTERNATIONAL ENDODONTIC JOURNAL, 2023, 56 (05) : 637 - 646
  • [40] Comparative Evaluation of Accuracy of Two Electronic Apex Locators in the Presence of Contemporary Irrigants: An In vitro Study
    Baruah, Queentaj
    Sinha, Nidhi
    Singh, Bijay
    Reddy, P. Narendranatha
    Baruah, Kaveri
    Augustine, Vaishak
    JOURNAL OF INTERNATIONAL SOCIETY OF PREVENTIVE AND COMMUNITY DENTISTRY, 2018, 8 (04): : 349 - 353