Ex Vivo Evaluation of the Accuracy of 3 Electronic Apex Locators in Different Environments: A Micro-Computed Tomography Study

被引:3
|
作者
Cinar, Firdevs [1 ]
Ustun, Yakup [2 ]
机构
[1] Ortoperio Dent Clin, Endodont, Kayseri, Turkey
[2] Erciyes Univ, Fac Dent, Dept Endodont, Kayseri, Turkey
来源
EUROPEAN ENDODONTIC JOURNAL | 2020年 / 5卷 / 03期
关键词
mini Root ZX; NaOCl; Propex pixi; Raypex; 5; ROOT-CANAL MORPHOLOGY; LENGTH DETERMINATION; SODIUM-HYPOCHLORITE; FILE SIZE; FORAMEN; CONSTRICTION; MOLARS; TEETH;
D O I
10.14744/eej.2020.30633
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective: The aim of this study was to compare the accuracy of three electronic apex locators (EALs) (Propex Pixi, Mini Root ZX, Raypex 5) in determining working length (WL) under different environments (existence of blood-pulp/sodium hypochlorite in root canal space) using micro-computed tomography (micro-CT) measurements. Methods: Twenty-five single-rooted human teeth that were scheduled for extraction were selected for the study. Measurements were performed with the Propex Pixi, Mini Root ZX, Raypex 5 in vivo conditions in the presence of NaOCl irrigant solution or blood-pulp tissue. After that the teeth were extracted and scanned using micro- CT. The measurements of WL obtained with the different EALs in different environments were statistically compared. Significance was set at P<0.05. Results: There were no significant differences among the WL measurements performed with EALs or micro CT groups under different clinical enviroments. All EALs tested gave reliable results in respect to apical constriction. Conclusion: The accuracy of the tested EALs is not affected by pulp tissues and blood or NaOCl.
引用
收藏
页码:226 / 230
页数:5
相关论文
共 50 条
  • [21] Micro-computed tomography evaluation of dentinal cracks after root canal preparation with different endodontic rotary files: An ex vivo study
    Alzamanan, Mohammed Mana
    Albassam, Abdullah Abdulrahman
    Khattab, Emad Mahmoud
    Alghamdi, Faisal Turki
    DENTAL AND MEDICAL PROBLEMS, 2025, 62 (01) : 89 - 98
  • [22] Evaluation of Urinary Stones Ex Vivo With Micro-Computed Tomography Preliminary Results of an Investigational Technique
    Huri, Emre
    Tatar, Ilkan
    Germiyanoglu, Cankon
    Karakan, Tolga
    Celik, Hakan Hamdi
    Ersoy, Orkun
    UROLOGY JOURNAL, 2011, 8 (03) : 185 - 190
  • [23] Quantitative evaluation of the accuracy of micro-computed tomography in tooth measurement
    Kim, Insoo
    Paik, Ki-Suk
    Lee, Seung-Pyo
    CLINICAL ANATOMY, 2007, 20 (01) : 27 - 34
  • [24] In vivo micro-computed tomography evaluation of radiopaque, polymeric device degradation in normal and inflammatory environments
    Pawelec, Kendell M.
    Hix, Jeremy M. L.
    Troia, Arianna
    Macrenaris, Keith W.
    Kiupel, Matti
    Shapiro, Erik M.
    ACTA BIOMATERIALIA, 2024, 181 : 222 - 234
  • [25] Ex vivo evaluation of the accuracy and coefficient of repeatability of three electronic apex locators using a simple mounting model: a preliminary report
    D'Assuncao, F. L. C.
    Albuquerque, D. S.
    Salazar-Silva, J. R.
    Dos Santos, V. C.
    Sousa, J. C. N.
    INTERNATIONAL ENDODONTIC JOURNAL, 2010, 43 (04) : 269 - 274
  • [26] Ex Vivo Visualization of the Mouse Otoconial Layer Compared With Micro-Computed Tomography
    Honda, Keiji
    Noguchi, Yoshihiro
    Kawashima, Yoshiyuki
    Takahashi, Masatoki
    Nishio, Ayako
    Kitamura, Ken
    OTOLOGY & NEUROTOLOGY, 2015, 36 (02) : 311 - 317
  • [27] Evaluation of Dentaport ZX and Raypex 6 electronic apex locators: An in vivo study
    Moscoso, Saddy
    Pineda, Kenneth
    Basilio, Juan
    Alvarado, Carlos
    Roig, Miguel
    Duran-Sindreu, Fernando
    MEDICINA ORAL PATOLOGIA ORAL Y CIRUGIA BUCAL, 2014, 19 (02): : E202 - E205
  • [28] Effects of three different embedding media on the accuracy of different electronic apex locators: An in vitro study
    Cudal, Hamza
    Kesim, Bertan
    Aslan, Tugrul
    ANNALS OF CLINICAL AND ANALYTICAL MEDICINE, 2022, 13 (01): : 80 - 83
  • [29] Ex vivo evaluation of the ability of four different electronic apex locators to determine the working length in teeth with various foramen diameters
    Ebrahim, A. K.
    Wadachi, R.
    Suda, H.
    AUSTRALIAN DENTAL JOURNAL, 2006, 51 (03) : 258 - 262
  • [30] In Vitro Evaluation of the Accuracy of Three Electronic Apex Locators Using Different Sodium Hypochlorite Concentrations
    Cimpean, Sanda Ileana
    Chisnoiu, Radu Marcel
    Burtea, Adela Loredana Colceriu
    Rotaru, Rares
    Bud, Marius Gheorghe
    Delean, Ada Gabriela
    Pop-Ciutrila, Ioana-Sofia
    MEDICINA-LITHUANIA, 2023, 59 (05):