On improving the accuracy of self-calibrated stereo digital image correlation system

被引:6
|
作者
Thiruselvam, N. Iniyan [1 ]
Subramanian, S. J. [2 ]
机构
[1] Indian Inst Technol Madras, Dept Engn Design, Chennai, Tamil Nadu, India
[2] PhotoGAUGE India Private Ltd, Chennai, Tamil Nadu, India
关键词
camera self-calibration; photogrammetry; convergent imaging configuration; feature tracking; stereo DIC; DSLR camera; macro lens; CAMERA CALIBRATION; STRAIN-MEASUREMENT;
D O I
10.1088/1361-6501/abae3b
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Stereo digital image correlation (stereo DIC), a full-field deformation measurement technique, is increasingly being used to resolve strains at mu m-length scale by using microscope-like imaging systems. Self calibration of these imaging systems is more cost-effective and convenient than the conventional target-based calibration. Though the use of self-calibrated stereo DIC systems has already been reported, less attention has been paid to improving the accuracy of these systems. In the present work, we improve the accuracy of a self-calibrated stereo DIC system, which is composed of two full-frame DSLR cameras coupled to macro lenses and is used for testing ASTM E8M sub-sized flat dog-bone specimens. First, we collect the images of two of the speckled test specimens that subtend an angle of 12 degrees between them using an f/25 aperture. Our image-collection strategy leads to a convergent imaging configuration with viewpoints that range from -45 degrees to 45 degrees across two perpendicular directions. Next, we process the collected images in a commercial photogrammetric calibration software by using more than nine image points for computing each object point. We validate our findings on a rigid-body motion test and a uniaxial tensile experiment, and we observe an excellent agreement between the stereo-DIC measurements and the ground truth. Using our findings, the reprojection error of self calibration is improved from 0.3 pixel to 0.1 pixel. The error in the stereo-DIC strain measurements is always less than 3.4% with the improvements made to self calibration, whereas it is as large as 7.6% without them.
引用
收藏
页数:16
相关论文
共 50 条
  • [41] Stereo Digital Image Correlation for Characterization of Fresh Biomaterials
    Bland, Megan E.
    Cortes, Marisol
    Solt, Kristin J.
    Siadat, Mohammad
    Yang, Lianxiang
    [J]. PHOTONIC THERAPEUTICS AND DIAGNOSTICS VI, 2010, 7548
  • [42] Automated Camera Exposure Control for Accuracy-Enhanced Stereo-Digital Image Correlation Measurement
    Zhang, Xiaoying
    Tang, Xiaojun
    Yu, Liping
    Pan, Bing
    [J]. SENSORS, 2022, 22 (24)
  • [43] SCRDN: Residual dense network with self-calibrated convolutions for low dose CT image denoising
    Ma, Limin
    Xue, Hengzhi
    Yang, Guangtong
    Zhang, Zitong
    Li, Chen
    Yao, Yudong
    Teng, Yueyang
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2023, 1045
  • [44] Lightweight Image Super-Resolution Based on Re-Parameterization and Self-Calibrated Convolution
    Zhang, Sufan
    Chen, Xi
    Huang, Xingwei
    [J]. COMPUTATIONAL INTELLIGENCE AND NEUROSCIENCE, 2022, 2022
  • [45] A 6-bit 500-Ms/s digital self-calibrated pipelined analog-to-digital converter
    Chen, YH
    Lee, TC
    [J]. PROCEEDINGS OF 2004 IEEE ASIA-PACIFIC CONFERENCE ON ADVANCED SYSTEM INTEGRATED CIRCUITS, 2004, : 98 - 101
  • [46] Optimization Design of Single- Camera Stereo- Digital Image Correlation System
    Qian, Siwei
    Liang, Junzhe
    Liang, Jin
    [J]. ACTA OPTICA SINICA, 2024, 44 (16)
  • [47] A high resolution Time-to-Digital Converter (TDC) based on self-calibrated Digital-to-Time Converter (DTC)
    Ouyang, Tingbing
    Wang, Bo
    Gao, Lizhao
    Gu, Jiangtao
    Zhang, Chao
    [J]. 2017 IEEE 60TH INTERNATIONAL MIDWEST SYMPOSIUM ON CIRCUITS AND SYSTEMS (MWSCAS), 2017, : 675 - 678
  • [48] Digital image correlation: displacement accuracy estimation
    Dupre, J. C.
    Bornert, M.
    Robert, L.
    Wattrisse, B.
    [J]. ICEM 14: 14TH INTERNATIONAL CONFERENCE ON EXPERIMENTAL MECHANICS, VOL 6, 2010, 6
  • [49] Self-Calibrated Knee Voltage Detector With 99.65% High Accuracy for AC Charger System in 0.5 μm 500 V UHV Process
    Chiu, Chao-Chang
    Lin, Moris
    Chang, Chih-Wei
    Meng, Che-Hao
    Yang, Hsiang-An
    Chen, Ke-Horng
    [J]. IEEE TRANSACTIONS ON CIRCUITS AND SYSTEMS I-REGULAR PAPERS, 2014, 61 (10) : 2786 - 2795
  • [50] A universal delay line circuit for variation resilient IC with self-calibrated time-to-digital converter
    Shao, Shuai
    Shi, Youhua
    Dai, Wentao
    Meng, Jianyi
    Shan, Weiwei
    [J]. PROCEEDINGS OF THE 2015 IEEE INTERNATIONAL CONFERENCE ON ELECTRON DEVICES AND SOLID-STATE CIRCUITS (EDSSC), 2015, : 126 - 129