On improving the accuracy of self-calibrated stereo digital image correlation system

被引:6
|
作者
Thiruselvam, N. Iniyan [1 ]
Subramanian, S. J. [2 ]
机构
[1] Indian Inst Technol Madras, Dept Engn Design, Chennai, Tamil Nadu, India
[2] PhotoGAUGE India Private Ltd, Chennai, Tamil Nadu, India
关键词
camera self-calibration; photogrammetry; convergent imaging configuration; feature tracking; stereo DIC; DSLR camera; macro lens; CAMERA CALIBRATION; STRAIN-MEASUREMENT;
D O I
10.1088/1361-6501/abae3b
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Stereo digital image correlation (stereo DIC), a full-field deformation measurement technique, is increasingly being used to resolve strains at mu m-length scale by using microscope-like imaging systems. Self calibration of these imaging systems is more cost-effective and convenient than the conventional target-based calibration. Though the use of self-calibrated stereo DIC systems has already been reported, less attention has been paid to improving the accuracy of these systems. In the present work, we improve the accuracy of a self-calibrated stereo DIC system, which is composed of two full-frame DSLR cameras coupled to macro lenses and is used for testing ASTM E8M sub-sized flat dog-bone specimens. First, we collect the images of two of the speckled test specimens that subtend an angle of 12 degrees between them using an f/25 aperture. Our image-collection strategy leads to a convergent imaging configuration with viewpoints that range from -45 degrees to 45 degrees across two perpendicular directions. Next, we process the collected images in a commercial photogrammetric calibration software by using more than nine image points for computing each object point. We validate our findings on a rigid-body motion test and a uniaxial tensile experiment, and we observe an excellent agreement between the stereo-DIC measurements and the ground truth. Using our findings, the reprojection error of self calibration is improved from 0.3 pixel to 0.1 pixel. The error in the stereo-DIC strain measurements is always less than 3.4% with the improvements made to self calibration, whereas it is as large as 7.6% without them.
引用
收藏
页数:16
相关论文
共 50 条
  • [21] Self-Calibrated Binocular Ranging System Based on Hardware SURF Algorithm
    Jiang Xiaodong
    Yu Jiyan
    Zhu Likun
    Huang Jiansen
    [J]. ACTA OPTICA SINICA, 2018, 38 (10)
  • [22] Multi-scale Self-calibrated Network for Image Light Source Transfer
    Wang, Yuanzhi
    Lu, Tao
    Zhang, Yanduo
    Wu, Yuntao
    [J]. 2021 IEEE/CVF CONFERENCE ON COMPUTER VISION AND PATTERN RECOGNITION WORKSHOPS, CVPRW 2021, 2021, : 252 - 259
  • [23] Efficient Image Super-Resolution via Self-Calibrated Feature Fuse
    Tan, Congming
    Cheng, Shuli
    Wang, Liejun
    [J]. SENSORS, 2022, 22 (01)
  • [24] Stereo digital image correlation: formulations and perspectives
    Fouque, Raphael
    Bouclier, Robin
    Passieux, Jean-Charles
    Perie, Jean-Noel
    [J]. COMPTES RENDUS MECANIQUE, 2021, 349 (02): : 453 - 463
  • [25] Phase shifting calibrated with digital image correlation method
    Jiang, M
    Tam, HY
    He, XY
    [J]. THIRD INTERNATIONAL CONFERENCE ON EXPERIMENTAL MECHANICS AND THIRD CONFERENCE OF THE ASIAN-COMMITTEE-ON-EXPERIMENTAL-MECHANICS, PTS 1AND 2, 2005, 5852 : 599 - 607
  • [26] Development of a Self-Calibrated Embedded System for Energy Management in Low Voltage
    da Silva, Eder Andrade
    Urzagasti, Carlos Alejandro
    Maciel, Joylan Nunes
    Gimenez Ledesma, Jorge Javier
    Cavallari, Marco Roberto
    Ando Junior, Oswaldo Hideo
    [J]. ENERGIES, 2022, 15 (22)
  • [27] Surface Decoration for Improving the Accuracy of Displacement Measurements by Digital Image Correlation in SEM
    B. Winiarski
    G. S. Schajer
    P. J. Withers
    [J]. Experimental Mechanics, 2012, 52 : 793 - 804
  • [28] Improving measurement accuracy of Brazilian tensile strength of rock by digital image correlation
    He, Wenhao
    Chen, Keyong
    Zhang, Baiyu
    Dong, Kanjicai
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2018, 89 (11):
  • [29] Surface Decoration for Improving the Accuracy of Displacement Measurements by Digital Image Correlation in SEM
    Winiarski, B.
    Schajer, G. S.
    Withers, P. J.
    [J]. EXPERIMENTAL MECHANICS, 2012, 52 (07) : 793 - 804
  • [30] A self-calibrated speaker tracking system using both audio and video data
    Hu, J
    Su, TM
    Cheng, CC
    Liu, WH
    Wu, TI
    [J]. PROCEEDINGS OF THE 2002 IEEE INTERNATIONAL CONFERENCE ON CONTROL APPLICATIONS, VOLS 1 & 2, 2002, : 731 - 735