Facile preparation of poly(methylene blue) modified carbon paste electrode for the detection and quantification of catechin

被引:90
|
作者
Manasa, G. [1 ]
Mascarenhas, Ronald J. [1 ]
Satpati, Ashis K. [2 ]
D'Souza, Ozma J. [1 ]
Dhason, A. [3 ]
机构
[1] St Josephs Coll, Dept Chem, Electrochem Res Grp, Lalbagh Rd, Bangalore 560027, Karnataka, India
[2] Bhabha Atom Res Ctr, Div Analyt Chem, Bombay 400094, Maharashtra, India
[3] Raman Res Inst, Soft Condensed Matter, Bangalore 560080, Karnataka, India
关键词
Modified carbon paste electrode; Methylene blue; Electropolymerization; Catechin; Differential pulse voltammetry; VOLTAMMETRIC DETERMINATION; URIC-ACID; ELECTROCHEMICAL-BEHAVIOR; PLANT POLYPHENOLS; METHYLENE-BLUE; ASCORBIC-ACID; GREEN TEA; SENSOR; NANOTUBES; (+)-CATECHIN;
D O I
10.1016/j.msec.2016.12.114
中图分类号
TB3 [工程材料学]; R318.08 [生物材料学];
学科分类号
0805 ; 080501 ; 080502 ;
摘要
Free radicals are formed as byproducts of metabolism, and are highly unstable due to the presence of unpaired electrons. They readily react with other important cellular components such as DNA causing them damage. Antioxidants such as (+)-catechin (CAT), neutralize free radicals in the blood stream. Hence there is a need for detection and quantification of catechin concentration in various food sources and beverages. Electro-oxidative properties of catechin were investigated using cyclic voltammetry (CV) and differential pulse voltammetry (DPV). A carbon paste working electrode modified by electropolymerizing methylene blue (MB) was fabricated. Field emission scanning electron microscopy (FESEM) and atomic force microscopy (AFM) techniques were used to study the surface morphology of the electrode. Quasi-reversible electron transfer reaction occurred at + 0.260 V through a diffusion controlled process. In comparison to the bare carbon paste electrode (CPE), there was a significant 5.3 times increment in anodic current sensitivity at the modified electrode at physiological pH. Our findings indicate that for the electro-oxidation of CAT, CPE is a better base material for electropolymerization of MB compared to glassy carbon electrode (GCE). Nyquist plot followed the theoretical shape, indicating low interfacial charge transfer resistance of 0.095 K Omega at the modified electrode. Calibration plots obtained by DPV were linear in two ranges of 1.0 x 10(-3) to 1.0 x 10(-8) and 1.0 x 10(-7) to 0.1 x 10(-8) M. The limit of detection (LOD) and limit of quantification (LOQ) was 4.9 nM and 14 nM respectively. Application of the developed electrode was demonstrated by detecting catechin in green tea and spiked fruit juice with satisfactory recoveries. The sensor was stable, sensitive, selective and reproducible. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:552 / 561
页数:10
相关论文
共 50 条
  • [21] A carbon paste electrode modified with kaolin for the detection of diquat
    El Mhammedi, M. A.
    Bakasse, M.
    Najih, R.
    Chtaini, A.
    APPLIED CLAY SCIENCE, 2009, 43 (01) : 130 - 134
  • [22] A carbon paste electrode modified with poly(methylene disulfide) nanoparticles for anodic stripping voltammetric determination of silver(I)
    Seyedeh Mina Ghalebi
    Vahid Zare-Shahabadi
    Hooshang Parham
    Microchimica Acta, 2019, 186
  • [23] A carbon paste electrode modified with poly(methylene disulfide) nanoparticles for anodic stripping voltammetric determination of silver(I)
    Ghalebi, Seyedeh Mina
    Zare-Shahabadi, Vahid
    Parham, Hooshang
    MICROCHIMICA ACTA, 2019, 186 (02)
  • [24] Facile Preparation of Ionic Liquid-coated Copper Nanowire-modified Carbon Paste Electrode for Electrochemical Detection of Etilefrine Drug
    Venkateswarlu, Sada
    Venu, Manthrapudi
    Reddy, Yenegu Veera Manohara
    Sravani, Bathinapatla
    Mallikarjuna, K.
    Yoon, Minyoung
    Madhavi, G.
    BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 2019, 40 (06) : 560 - 565
  • [25] Nanomolar determination of 4-nitrophenol based on a poly(methylene blue)-modified glassy carbon electrode
    Giribabu, Krishnamoorthy
    Suresh, Ranganathan
    Manigandan, Ramadoss
    Munusamy, Settu
    Kumar, Sivakumar Praveen
    Muthamizh, Selvamani
    Narayanan, Vengidusamy
    ANALYST, 2013, 138 (19) : 5811 - 5818
  • [26] Preparation and Application of the Hyperbranched Polymer Modified Carbon Paste Electrode
    Zhou Chang-Li
    Zheng Yu-Xin
    Chen Hong-Wei
    Shou Chong-Qi
    Dong Yan-Min
    Liu Zhen
    Chen Li-Ren
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2009, 37 (01) : 111 - 114
  • [27] Poly(o-aminophenol)-modified bienzyme carbon paste electrode for the detection of uric acid
    Miland, E
    Ordieres, AJM
    Blanco, PT
    Smyth, MR
    Fagain, CO
    TALANTA, 1996, 43 (05) : 785 - 796
  • [28] Poly(Methylene Blue) Modified Carbon-based Electrodes for Electrochemical Detection of Hydrogen Sulfide
    Zlamalova, Magda
    Janda, Pavel
    Nesmerak, Karel
    XXXVI MODERNI ELEKTROCHEMICKE METODY, 2016, : 289 - 293
  • [29] Mordant black modified glassy carbon electrode for the determination of methylene blue
    Bendany, Mohamed
    Ben Brahim, Khalid Ait
    El Hamdouni, Youssra
    Oumoussa, Hajar
    Labjar, Najoua
    Dahrouche, Abdelouahed
    Dalimi, Mohamed
    Omari, Mohamed
    Jebbari, Said
    Nasrellah, Hamid
    El Hajjaji, Souad
    EURO-MEDITERRANEAN JOURNAL FOR ENVIRONMENTAL INTEGRATION, 2024,
  • [30] Fabrication of Poly (Evans blue) Modified Graphite Paste Electrode as an Electrochemical Sensor for Sensitive and Instant Riboflavin Detection
    Charithra, M. M.
    Manjunatha, J. G.
    MOROCCAN JOURNAL OF CHEMISTRY, 2021, 9 (01): : 7 - 17