Facile preparation of poly(methylene blue) modified carbon paste electrode for the detection and quantification of catechin

被引:90
|
作者
Manasa, G. [1 ]
Mascarenhas, Ronald J. [1 ]
Satpati, Ashis K. [2 ]
D'Souza, Ozma J. [1 ]
Dhason, A. [3 ]
机构
[1] St Josephs Coll, Dept Chem, Electrochem Res Grp, Lalbagh Rd, Bangalore 560027, Karnataka, India
[2] Bhabha Atom Res Ctr, Div Analyt Chem, Bombay 400094, Maharashtra, India
[3] Raman Res Inst, Soft Condensed Matter, Bangalore 560080, Karnataka, India
关键词
Modified carbon paste electrode; Methylene blue; Electropolymerization; Catechin; Differential pulse voltammetry; VOLTAMMETRIC DETERMINATION; URIC-ACID; ELECTROCHEMICAL-BEHAVIOR; PLANT POLYPHENOLS; METHYLENE-BLUE; ASCORBIC-ACID; GREEN TEA; SENSOR; NANOTUBES; (+)-CATECHIN;
D O I
10.1016/j.msec.2016.12.114
中图分类号
TB3 [工程材料学]; R318.08 [生物材料学];
学科分类号
0805 ; 080501 ; 080502 ;
摘要
Free radicals are formed as byproducts of metabolism, and are highly unstable due to the presence of unpaired electrons. They readily react with other important cellular components such as DNA causing them damage. Antioxidants such as (+)-catechin (CAT), neutralize free radicals in the blood stream. Hence there is a need for detection and quantification of catechin concentration in various food sources and beverages. Electro-oxidative properties of catechin were investigated using cyclic voltammetry (CV) and differential pulse voltammetry (DPV). A carbon paste working electrode modified by electropolymerizing methylene blue (MB) was fabricated. Field emission scanning electron microscopy (FESEM) and atomic force microscopy (AFM) techniques were used to study the surface morphology of the electrode. Quasi-reversible electron transfer reaction occurred at + 0.260 V through a diffusion controlled process. In comparison to the bare carbon paste electrode (CPE), there was a significant 5.3 times increment in anodic current sensitivity at the modified electrode at physiological pH. Our findings indicate that for the electro-oxidation of CAT, CPE is a better base material for electropolymerization of MB compared to glassy carbon electrode (GCE). Nyquist plot followed the theoretical shape, indicating low interfacial charge transfer resistance of 0.095 K Omega at the modified electrode. Calibration plots obtained by DPV were linear in two ranges of 1.0 x 10(-3) to 1.0 x 10(-8) and 1.0 x 10(-7) to 0.1 x 10(-8) M. The limit of detection (LOD) and limit of quantification (LOQ) was 4.9 nM and 14 nM respectively. Application of the developed electrode was demonstrated by detecting catechin in green tea and spiked fruit juice with satisfactory recoveries. The sensor was stable, sensitive, selective and reproducible. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:552 / 561
页数:10
相关论文
共 50 条
  • [11] Electrochemical behavior of an anticancer drug 5-fluorouracil at methylene blue modified carbon paste electrode
    Bukkitgar, Shikandar D.
    Shetti, Nagaraj P.
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2016, 65 : 262 - 268
  • [12] Preparation and characteristic of cobalt phthalocyanine modified carbon paste electrode for bisphenol A detection
    Yin, Huan-shun
    Zhou, Yun-lei
    Ai, Shi-yun
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2009, 626 (1-2) : 80 - 88
  • [13] Is the poly (methylene blue)-modified glassy carbon electrode an adequate electrode for the simple detection of thiols and amino acid-based molecules?
    Costa Marinho, Maria Ines
    Cabral, Murilo Feitosa
    Mazo, Luiz Henrique
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2012, 685 : 8 - 14
  • [14] Electrochemical Studies of Paracetamol at Poly (Aniline Blue) Modified Carbon Paste Electrode: A Voltammetric Study
    Vishwanath, Chandrashekar C.
    Swamy, Bahaddurghatta E. Kumara
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2014, 6 (05): : 573 - 582
  • [15] Carbon paste electrodes modified with methylene blue immobilized on a synthetic zeolite
    Varodi, Codruta
    Gligor, Delia
    Muresan, Liana M.
    REVUE ROUMAINE DE CHIMIE, 2007, 52 (1-2) : 81 - 88
  • [16] Poly (Alanine) Modified Carbon Paste Electrode for Simultaneous Detection of Dopamine and Ascorbic Acid
    Gilbert, Ongera
    Chandra, Umesh
    Swamy, B. E. Kumara
    Char, M. Panduranga
    Nagaraj, C.
    Sherigard, B. S.
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2008, 3 (10): : 1186 - 1195
  • [17] Hydrogen sulfide detection by poly(methylene blue) modified highly oriented pyrolytic graphite electrode
    Magda Zlámalová
    Pavel Janda
    Karel Nesměrák
    Monatshefte für Chemie - Chemical Monthly, 2017, 148 : 1595 - 1597
  • [18] Hydrogen sulfide detection by poly(methylene blue) modified highly oriented pyrolytic graphite electrode
    Zlamalova, Magda
    Janda, Pavel
    Nesmrak, Karel
    MONATSHEFTE FUR CHEMIE, 2017, 148 (09): : 1595 - 1597
  • [19] Photoelectrochemical investigation of methylene blue immobilised on zirconium phosphate modified carbon paste electrode in flow injection system
    Dilgin, Y
    Dursun, Z
    Nisli, G
    Gorton, L
    ANALYTICA CHIMICA ACTA, 2005, 542 (02) : 162 - 168
  • [20] Simultaneous electroanalysis of hydroquinone and catechol at poly(brilliant blue) modified carbon paste electrode: A voltammetric study
    Ganesh, P. S.
    Swamy, B. E. Kumara
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2015, 756 : 193 - 200