Facile preparation of poly(methylene blue) modified carbon paste electrode for the detection and quantification of catechin

被引:90
|
作者
Manasa, G. [1 ]
Mascarenhas, Ronald J. [1 ]
Satpati, Ashis K. [2 ]
D'Souza, Ozma J. [1 ]
Dhason, A. [3 ]
机构
[1] St Josephs Coll, Dept Chem, Electrochem Res Grp, Lalbagh Rd, Bangalore 560027, Karnataka, India
[2] Bhabha Atom Res Ctr, Div Analyt Chem, Bombay 400094, Maharashtra, India
[3] Raman Res Inst, Soft Condensed Matter, Bangalore 560080, Karnataka, India
关键词
Modified carbon paste electrode; Methylene blue; Electropolymerization; Catechin; Differential pulse voltammetry; VOLTAMMETRIC DETERMINATION; URIC-ACID; ELECTROCHEMICAL-BEHAVIOR; PLANT POLYPHENOLS; METHYLENE-BLUE; ASCORBIC-ACID; GREEN TEA; SENSOR; NANOTUBES; (+)-CATECHIN;
D O I
10.1016/j.msec.2016.12.114
中图分类号
TB3 [工程材料学]; R318.08 [生物材料学];
学科分类号
0805 ; 080501 ; 080502 ;
摘要
Free radicals are formed as byproducts of metabolism, and are highly unstable due to the presence of unpaired electrons. They readily react with other important cellular components such as DNA causing them damage. Antioxidants such as (+)-catechin (CAT), neutralize free radicals in the blood stream. Hence there is a need for detection and quantification of catechin concentration in various food sources and beverages. Electro-oxidative properties of catechin were investigated using cyclic voltammetry (CV) and differential pulse voltammetry (DPV). A carbon paste working electrode modified by electropolymerizing methylene blue (MB) was fabricated. Field emission scanning electron microscopy (FESEM) and atomic force microscopy (AFM) techniques were used to study the surface morphology of the electrode. Quasi-reversible electron transfer reaction occurred at + 0.260 V through a diffusion controlled process. In comparison to the bare carbon paste electrode (CPE), there was a significant 5.3 times increment in anodic current sensitivity at the modified electrode at physiological pH. Our findings indicate that for the electro-oxidation of CAT, CPE is a better base material for electropolymerization of MB compared to glassy carbon electrode (GCE). Nyquist plot followed the theoretical shape, indicating low interfacial charge transfer resistance of 0.095 K Omega at the modified electrode. Calibration plots obtained by DPV were linear in two ranges of 1.0 x 10(-3) to 1.0 x 10(-8) and 1.0 x 10(-7) to 0.1 x 10(-8) M. The limit of detection (LOD) and limit of quantification (LOQ) was 4.9 nM and 14 nM respectively. Application of the developed electrode was demonstrated by detecting catechin in green tea and spiked fruit juice with satisfactory recoveries. The sensor was stable, sensitive, selective and reproducible. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:552 / 561
页数:10
相关论文
共 50 条
  • [1] Construction of Poly(methylene blue) on Carbon Nanotubes Ionic Liquid Paste Electrode for Sensitive Detection of Nitrite
    Li, Yonghong
    Liu, Xinling
    Zeng, Xiandong
    Liu, Xiaoying
    Tao, Ling
    Wei, Wanzhi
    Luo, Shenglian
    SENSOR LETTERS, 2010, 8 (04) : 584 - 590
  • [2] A Novel and Selective Methylene Blue Imprinted Polymer Modified Carbon Paste Electrode
    Soysal, Mert
    Muti, Mihrican
    Esen, Cem
    Gencdag, Kubra
    Aslan, Alican
    Erdem, Arzum
    Karagoezler, A. Ersin
    ELECTROANALYSIS, 2013, 25 (05) : 1278 - 1285
  • [3] Carbon paste electrode incorporating calcium-exchanged zeolite modified with Methylene Blue for amperometric detection of NADH
    Varodi, Codruta
    Gligor, Delia
    Maicaneanu, Andrada
    Muresan, Liana M.
    REVISTA DE CHIMIE, 2007, 58 (09): : 890 - 894
  • [4] Poly(methylene blue) functionalized graphene modified carbon ionic liquid electrode for the electrochemical detection of dopamine
    Sun, Wei
    Wang, Yuhua
    Zhang, Yuanyuan
    Ju, Xiaomei
    Li, Guangjiu
    Sun, Zhenfan
    ANALYTICA CHIMICA ACTA, 2012, 751 : 59 - 65
  • [5] Amperometric Determination of Nitrite at Poly(Methylene Blue)-Modified Glassy Carbon Electrode
    Xu, Guang-Ri
    Xu, Guifang
    Xu, Ming-Lu
    Zhang, Zhengqing
    Tian, Yuan
    Cho, Han Nim
    Lee, Won-Yong
    BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 2012, 33 (02): : 415 - 419
  • [6] Electrochemical detection and quantification of catechol based on a simple and sensitive poly(riboflavin) modified carbon nanotube paste electrode
    Hareesha, N.
    Manjunatha, J. G.
    Tighezza, Ammar M.
    Albaqami, Munirah D.
    Sillanpaa, Mika
    HELIYON, 2023, 9 (03)
  • [7] Poly(methylene blue) modified electrode sensor for haemoglobin
    Brett, CMA
    Inzelt, G
    Kertesz, V
    ANALYTICA CHIMICA ACTA, 1999, 385 (1-3) : 119 - 123
  • [8] A catechin-modified carbon paste electrode for electrocatalytic determination of neurotransmitters
    Wei, Juan
    He, Jianbo
    Chen, Changlun
    Wang, Xiangke
    ANALYTICAL METHODS, 2015, 7 (13) : 5641 - 5648
  • [9] A novel carbon paste electrode modified with Argan oil cake waste / zinc oxide nanoparticles composite for methylene blue detection
    Abbi, Khaoula
    Hermouche, Lina
    El Hamdouni, Youssra
    Rahmani, Maryem
    Benhsina, Elhassan
    Labjar, Najoua
    Skalli, Abdelmajid
    El Mahi, Mohammed
    Lotfi, El Mostapha
    Dalimi, Mohamed
    El Hajjaji, Souad
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2024, 104 (06) : 1291 - 1306
  • [10] Poly(Rhodamine B) modified carbon paste electrode for the selective detection of dopamine
    Thomas, Tony
    Mascarenhas, Ronald J.
    Swamy, B. E. Kumara
    JOURNAL OF MOLECULAR LIQUIDS, 2012, 174 : 70 - 75