Comparison of Shape-based Analysis of Retinal Nerve Fiber Layer Data Obtained From OCT and GDx-VCC

被引:5
|
作者
Gunvant, Pinakin [1 ,3 ]
Zheng, Yufeng [2 ,3 ]
Essock, Edward A. [3 ,4 ]
Parikh, Rajul S. [5 ,6 ]
Prabakaran, Selvaraj [5 ,7 ]
Babu, Jonnadula Ganesh [5 ]
Shekar, Chandra G. [5 ]
Thomas, Ravi [5 ,8 ]
机构
[1] So Coll Optometry, Dept Res, Memphis, TN 38104 USA
[2] Alcorn State Univ, Dept Adv Technol, Lorman, MS USA
[3] Univ Louisville, Dept Psychol & Brain Sci, Louisville, KY 40292 USA
[4] Univ Louisville, Dept Ophthalmol & Vis Sci, Louisville, KY 40292 USA
[5] LV Prasad Eye Inst, VST Glaucoma Serv, Hyderabad, Andhra Pradesh, India
[6] Bombay City Eye Inst & Res Ctr, Dept Glaucoma, Mumbai, Maharashtra, India
[7] Natl Univ Singapore, Dept Community Occupat & Family Med, Singapore 117548, Singapore
[8] Univ Queensland, Brisbane, Qld 4072, Australia
关键词
Wavelet-Fourier analysis; Fourier analysis; optical coherence tomograph; GDx-VCC; retinal nerve fiber layer; glaucoma; SCANNING LASER POLARIMETRY; OPTICAL COHERENCE TOMOGRAPHY; ENHANCED CORNEAL COMPENSATION; WAVELET-FOURIER ANALYSIS; VISUAL-FIELD LOSS; THICKNESS MEASUREMENTS; GLAUCOMATOUS EYES; DIAGNOSTIC-ACCURACY; STRATUS OCT; REPRODUCIBILITY;
D O I
10.1097/IJG.0b013e31818c6f2b
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To directly compare in I population: (1) the performance of Optical Coherence Tomograph (OCT) and GDx-Variable Corneal Compensator (VCC) when using Wavelet-Fourier Analysis (WFA) and Fast-Fourier Analysis (FFA), (2) the performance of these shape-based and standard metrics, and (3) the shape of the retinal nerve fiber layer (RNFL) temporal, superior, nasal, inferior, temporal (TSNIT) curves obtained by the 2 different devices. Methods: RNFL estimates were obtained from 136 eyes of 136 individuals (73 healthy and 63 mild glaucoma). WFA and FFA with and without asymmetry measures were performed on the TSNIT RNFL estimates to identify glaucoma from healthy eyes. Performance of WFA, FFA, and the standard metrics of OCT (inferior Average) and GDX-VCC (Nerve Fiber Indicator) was evaluated by calculating receiver operating characteristic area. Measurements were obtained at a custom radius (33 to 41 pixels) for GDx-VCC to match the OCT radius (1.73 mm). Results: WFA and FFA shape analysis significantly improved performance of both OCT (0.937) and GDx-VCC (0.913) compared with Inferior Average and Nerve Fiber Indicator (0.852 and 0.833, respectively). With either shape-based or standard metrics, OCT performance was slightly, but not significantly, better than GDx-VCC performance. Comparison of RNFL curves revealed that the GDx-VCC curves were more jagged and the peaks shifted more nasally when compared with the OCT RNFL curves. Conclusions: Performance of both OCT and GDx-VCC devices are improved by shape-based analysis methods. Classification performance was greater when using WFA for the OCT, and greater with FFA for the GDx-VCC. Significant differences between the machines exist in the measured TSNIT thicknesses, possibly because of GDx-VCC's measurements being affected by polarization magnitude varying with angle.
引用
收藏
页码:464 / 471
页数:8
相关论文
共 50 条
  • [1] Retinal nerve fiber layer images captured by GDx-VCC in early diagnosis of glaucoma
    Wang Zheng
    Cui Baohua
    Cao Qun
    Qiao Zhi
    Dai Hong
    [J]. OPHTHALMOLOGICA, 2008, 222 (01) : 17 - 20
  • [2] Application of shape-based analysis methods to OCT retinal nerve fiber layer data in glaucoma
    Gunvant, Pinakin
    Zheng, Yufeng
    Essock, Edward A.
    Parikh, Rajul S.
    Prabakaran, Selvaraj
    Babu, Jonnadula Ganesh
    Shekar, Garudadri Chandra
    Thomas, Ravi
    [J]. JOURNAL OF GLAUCOMA, 2007, 16 (06) : 543 - 548
  • [3] Intersession reproducibility of retinal nerve fiber layer thickness measurements by GDx-VCC in healthy and glaucomatous eyes
    Iacono, Pierluigi
    Da Pozzo, Stefano
    Fuser, Mirko
    Marchesan, Roberta
    Ravalico, Giuseppe
    [J]. OPHTHALMOLOGICA, 2006, 220 (04) : 266 - 271
  • [4] Comparative study of retinal nerve fibre layer measurement by RTVue OCT and GDx VCC
    Wang, Xiaozhen
    Li, Shuning
    Fu, Jing
    Wu, Gewei
    Mu, Dapeng
    Li, Songfeng
    Wang, Jian
    Wang, Ningli
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 2011, 95 (04) : 509 - 513
  • [5] Atypical pattern of retardation on GDx-VCC and its effect on retinal nerve fibre layer evaluation in glaucomatous eyes
    S Da Pozzo
    R Marchesan
    T Canziani
    O Vattovani
    G Ravalico
    [J]. Eye, 2006, 20 : 769 - 775
  • [6] Atypical pattern of retardation on GDx-VCC and its effect on retinal nerve fibre layer evaluation in glaucomatous eyes
    Da Pozzo, S.
    Marchesan, R.
    Canziani, T.
    Vattovani, O.
    Ravalico, G.
    [J]. EYE, 2006, 20 (07) : 769 - 775
  • [7] Early glaucoma detection using the Humphrey Matrix perimeter, GDx VCC, stratus OCT, and retinal nerve fiber layer photography
    Hong, Samin
    Ahn, Hyunseok
    Ha, Seung Joo
    Yeom, Ho Yeop
    Seong, Gong Je
    Hong, Young Jae
    [J]. OPHTHALMOLOGY, 2007, 114 (02) : 210 - 215
  • [8] The Diagnostic Ability of the GDx-VCC Nerve Fiber Indicator (NFI) in Separating Healty From Glaucomatous Eyes
    Zanei, A.
    Vattovani, O.
    Di Stefano, G.
    Ravalico, G.
    Tognetto, D.
    Da Pozzo, S.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [9] Long-term variability of GDx VCC retinal nerve fiber layer thickness measurements
    Medeiros, Felipe A.
    Doshi, Rishi
    Zangwill, Linda M.
    Vasile, Cristiana
    Weinreb, Robert N.
    [J]. JOURNAL OF GLAUCOMA, 2007, 16 (03) : 277 - 281
  • [10] Preperimetric glaucoma assessment with scanning laser polarimetry (GDx VCC) -: Analysis of retinal nerve fiber layer by sectors
    Baraibar, Begona
    Sanchez-Cano, Ana
    Pablo, Luis E.
    Honrubia, Francisco M.
    [J]. JOURNAL OF GLAUCOMA, 2007, 16 (08) : 659 - 664