机构:
Univ Calif San Diego, Hamilton Glaucoma Ctr, Dept Ophthalmol, La Jolla, CA 92093 USAUniv Calif San Diego, Hamilton Glaucoma Ctr, Dept Ophthalmol, La Jolla, CA 92093 USA
Medeiros, Felipe A.
[1
]
Doshi, Rishi
论文数: 0引用数: 0
h-index: 0
机构:
Univ Calif San Diego, Hamilton Glaucoma Ctr, Dept Ophthalmol, La Jolla, CA 92093 USAUniv Calif San Diego, Hamilton Glaucoma Ctr, Dept Ophthalmol, La Jolla, CA 92093 USA
Doshi, Rishi
[1
]
Zangwill, Linda M.
论文数: 0引用数: 0
h-index: 0
机构:
Univ Calif San Diego, Hamilton Glaucoma Ctr, Dept Ophthalmol, La Jolla, CA 92093 USAUniv Calif San Diego, Hamilton Glaucoma Ctr, Dept Ophthalmol, La Jolla, CA 92093 USA
Zangwill, Linda M.
[1
]
Vasile, Cristiana
论文数: 0引用数: 0
h-index: 0
机构:
Univ Calif San Diego, Hamilton Glaucoma Ctr, Dept Ophthalmol, La Jolla, CA 92093 USAUniv Calif San Diego, Hamilton Glaucoma Ctr, Dept Ophthalmol, La Jolla, CA 92093 USA
Vasile, Cristiana
[1
]
Weinreb, Robert N.
论文数: 0引用数: 0
h-index: 0
机构:
Univ Calif San Diego, Hamilton Glaucoma Ctr, Dept Ophthalmol, La Jolla, CA 92093 USAUniv Calif San Diego, Hamilton Glaucoma Ctr, Dept Ophthalmol, La Jolla, CA 92093 USA
Weinreb, Robert N.
[1
]
机构:
[1] Univ Calif San Diego, Hamilton Glaucoma Ctr, Dept Ophthalmol, La Jolla, CA 92093 USA
Purpose: To evaluate the long-term variability of GDx VCC retinal nerve fiber layer (RNFL) thickness measurements. Methods: The study enrolled a cohort of glaucoma suspects who did not develop any evidence of visual field damage or change in the appearance of the optic nerve during an average follow-up of 9.1 +/- 3.2 years. Subjects underwent ocular imaging using the commercially available GDx VCC scanning laser polarimeter. At each visit, each eye was imaged 3 times. Subjects underwent repeated testing with GDx VCC at approximately 12-month intervals during their follow-up. In total, 255 examinations were obtained in 31 eyes of 31 individuals during an average GDx VCC follow-up time of 26.0 +/- 8.9 months. A random effects analysis of variance model was used to estimate intraclass correlation coefficients and long-term and short-term variability estimates. Results: Intraclass correlation coefficients ranged from 0.77 to 0.86 for GDx VCC parameters. Short-term variability estimates ranged from 2.45 to 3.89 mu m for RNFL thickness parameters, whereas the short-term variability estimate for the parameter Nerve Fiber Indicator was 3.71. Long-term variability was slightly higher than short-term variability for all parameters. For RNFL thickness parameters, long-term variability estimates ranged from 3.21 to 4.97 mu m, whereas for the parameter Nerve Fiber Indicator the long-term variability estimate was 4.93. Conclusions: RNFL measurements obtained with the GDx VCC were found to be highly reproducible in a long-term test-retest situation, supporting the use of this instrument for longitudinal assessment of the RNFL.
机构:
Beijing Union Med Coll Hosp, Dept Ophthalmol, Beijing 100730, Peoples R ChinaBeijing Union Med Coll Hosp, Dept Ophthalmol, Beijing 100730, Peoples R China
Wang Zheng
Cui Baohua
论文数: 0引用数: 0
h-index: 0
机构:
Beijing Union Med Coll Hosp, Dept Ophthalmol, Beijing 100730, Peoples R ChinaBeijing Union Med Coll Hosp, Dept Ophthalmol, Beijing 100730, Peoples R China
Cui Baohua
Cao Qun
论文数: 0引用数: 0
h-index: 0
机构:
Beijing Union Med Coll Hosp, Dept Ophthalmol, Beijing 100730, Peoples R ChinaBeijing Union Med Coll Hosp, Dept Ophthalmol, Beijing 100730, Peoples R China
Cao Qun
Qiao Zhi
论文数: 0引用数: 0
h-index: 0
机构:
Beijing Union Med Coll Hosp, Dept Ophthalmol, Beijing 100730, Peoples R ChinaBeijing Union Med Coll Hosp, Dept Ophthalmol, Beijing 100730, Peoples R China
Qiao Zhi
Dai Hong
论文数: 0引用数: 0
h-index: 0
机构:
Beijing Union Med Coll Hosp, Dept Ophthalmol, Beijing 100730, Peoples R ChinaBeijing Union Med Coll Hosp, Dept Ophthalmol, Beijing 100730, Peoples R China