Comparative study of retinal nerve fibre layer measurement by RTVue OCT and GDx VCC

被引:24
|
作者
Wang, Xiaozhen [1 ]
Li, Shuning [1 ]
Fu, Jing [1 ]
Wu, Gewei [2 ]
Mu, Dapeng [1 ]
Li, Songfeng [1 ]
Wang, Jian [1 ]
Wang, Ningli [1 ]
机构
[1] Capital Med Univ, Beijing Tongren Eye Ctr, Beijing Tongren Hosp, Beijing Ophthalmol & Visual Sci Key Lab, Beijing, Peoples R China
[2] Beijing Shi Jing Shan Hosp, Beijing, Peoples R China
关键词
OPTICAL COHERENCE TOMOGRAPHY; GLAUCOMA DETECTION; LAMINA-CRIBROSA; DOMAIN; HEAD; EYES; STRATUSOCT; ACCURACY; DEFECTS;
D O I
10.1136/bjo.2009.163493
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Aim To evaluate the diagnostic performances and correlations of retinal nerve fibre layer (RNFL) thickness measured by RTVue OCT and GDx variable corneal compensation (VCC). Methods The total and regional RNFL thickness were measured by RTVue OCT and GDx VCC in 62 normal eyes and 72 glaucomatous eyes of Chinese subjects. The RNFL thickness profiles of normal and glaucomatous eyes by RTVue OCT are plotted. Correlations of RNFL thickness measured by RTVue OCT and GDx VCC were assessed using the Pearson correlation. The discriminating abilities of the two techniques for detection of glaucoma were compared by the area under the receiver operating characteristic curves (AUC). Results RTVue OCT demonstrated double hump patterns in the RNFL profiles. In both normal and glaucomatous subjects, the peaks were located in the superotemporal (ST) and inferotemporal (IT) regions, and the troughs were located at the nasal (NU+ NL) and temporal (TU + TL) regions. Despite poor agreement, a high correlation (r=0.821) was found between the mean RNFL measurements by RTVue OCT and GDx VCC. For RTVue OCT, the highest AUCs were mean RNFL (AUC=0.914) and inferior mean RNFL (AUC=0.909). The nerve fibre indicator (AUC=0.856) and inferior RNFL (AUC=0.852) achieved the highest AUCs among all the GDx VCC measurements. The mean RNFL in RTVue OCT had the greatest AUC in the two devices. There was a significant difference in comparing the AUCs of the mean RNFL thickness obtained by RTVue OCT and GDx VCC (p=0.009). Conclusions Although there were absolute value differences in RNFL thickness, a high correlation was observed between RTVue OCT and GDx VCC. RTVue OCT shows a reasonable ability to distinguish normal from glaucomatous eyes.
引用
收藏
页码:509 / 513
页数:5
相关论文
共 50 条
  • [1] Comparative study of retinal nerve fiber layer measurement by StratusOCT and GDx VCC, I: Correlation analysis in glaucoma
    Leung, CKS
    Chan, WM
    Chong, KKL
    Yung, WH
    Tang, KT
    Woo, J
    Chan, WM
    Tse, KK
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46 (09) : 3214 - 3220
  • [2] Comparative study of retinal nerve fiber layer measurement by StratusOCT and GDx VCC, II: Structure/function regression analysis in glaucoma
    Leung, CKS
    Chong, KKL
    Chan, WM
    Yiu, CKF
    Tso, MY
    Woo, J
    Tsang, MK
    Tse, KK
    Yung, WH
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46 (10) : 3702 - 3711
  • [3] Position of retinal blood vessels correlates with retinal nerve fibre layer thickness profiles as measured with GDx VCC and ECC
    Resch, Hemma
    Brela, Barbara
    Resch-Wolfslehner, Christa
    Vass, Clemens
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 2011, 95 (05) : 680 - 684
  • [4] Atypical pattern of retardation on GDx-VCC and its effect on retinal nerve fibre layer evaluation in glaucomatous eyes
    S Da Pozzo
    R Marchesan
    T Canziani
    O Vattovani
    G Ravalico
    [J]. Eye, 2006, 20 : 769 - 775
  • [5] Atypical pattern of retardation on GDx-VCC and its effect on retinal nerve fibre layer evaluation in glaucomatous eyes
    Da Pozzo, S.
    Marchesan, R.
    Canziani, T.
    Vattovani, O.
    Ravalico, G.
    [J]. EYE, 2006, 20 (07) : 769 - 775
  • [6] Comparison of optical coherence tomography (OCT-3) and scanning laser polarimetry (GDx VCC) for detecting retinal nerve fibre layer thinning in multiple sclerosis
    Balcer, L.
    Zaveri, M.
    Conger, A.
    Frohman, T.
    Binkholder, B.
    Galetta, S.
    Markowitz, C.
    Jacobs, D.
    Cutter, G.
    Calabresi, R.
    Froliman, E.
    [J]. MULTIPLE SCLEROSIS, 2007, 13 : S32 - S32
  • [7] Early glaucoma detection using the Humphrey Matrix perimeter, GDx VCC, stratus OCT, and retinal nerve fiber layer photography
    Hong, Samin
    Ahn, Hyunseok
    Ha, Seung Joo
    Yeom, Ho Yeop
    Seong, Gong Je
    Hong, Young Jae
    [J]. OPHTHALMOLOGY, 2007, 114 (02) : 210 - 215
  • [8] Comparison of Shape-based Analysis of Retinal Nerve Fiber Layer Data Obtained From OCT and GDx-VCC
    Gunvant, Pinakin
    Zheng, Yufeng
    Essock, Edward A.
    Parikh, Rajul S.
    Prabakaran, Selvaraj
    Babu, Jonnadula Ganesh
    Shekar, Chandra G.
    Thomas, Ravi
    [J]. JOURNAL OF GLAUCOMA, 2009, 18 (06) : 464 - 471
  • [9] Comparison of two retinal nerve fibre layer thickness measurement patterns of RTvue optical coherence tomography
    Li, Shuning
    Wang, Xiaozhen
    Wu, Gewei
    Fu, Jing
    Li, Songfeng
    Wan, Xiuhua
    Wang, Ningli
    [J]. CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2011, 39 (03): : 222 - 229
  • [10] Long-term variability of GDx VCC retinal nerve fiber layer thickness measurements
    Medeiros, Felipe A.
    Doshi, Rishi
    Zangwill, Linda M.
    Vasile, Cristiana
    Weinreb, Robert N.
    [J]. JOURNAL OF GLAUCOMA, 2007, 16 (03) : 277 - 281