Evaluation of Human Corneal Lenticule Quality After SMILE With Different Cap Thicknesses Using Scanning Electron Microscopy

被引:14
|
作者
Weng, Shengbei [1 ]
Liu, Manli [1 ]
Yang, Xiaonan [1 ]
Liu, Fang [1 ]
Zhou, Yugui [1 ]
Lin, Haiqin [1 ]
Liu, Quan [1 ]
机构
[1] Sun Yat Sen Univ, Zhongshan Ophthalm Ctr, State Key Lab Ophthalmol, Guangzhou 510060, Guangdong, Peoples R China
关键词
small-incision lenticule extraction; scanning electron microscope; cap thicknesses; surface regularity; lenticule; EXTRACTION SMILE; FLAP DIMENSIONS; SURFACE QUALITY; EXCIMER-LASER; KERATOMILEUSIS; OUTCOMES; SURGERY; MYOPIA; MODEL; LASIK;
D O I
10.1097/ICO.0000000000001404
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate the surface characteristics of lenticules created by small-incision lenticule extraction (SMILE) with different cap thicknesses. Methods: This prospective study included 20 consecutive patients who underwent bilateral SMILE. Surface regularity of the extracted corneal lenticule was analyzed using scanning electron microscopy (SEM) combined with 2 methods: qualitative and quantitative regularity. Qualitative regularity of SEM images was graded by masked observers using an established scoring system. Quantitative regularity of SEM images was assessed by counting the total number and areas of tissue bridges using Image-Pro Plus software. Four different cap thickness of 120, 130, 140, and 150 mm were compared. Refractive outcomes of patients were measured at baseline and 1 month after surgery. Results: As 10 specimens were not analyzable, only 30 eyes were included. Postoperatively, all eyes had postoperative uncorrected distance visual acuity of 20/20 or better; 43% had an unchanged corrected distance visual acuity; 43% gained 1 line; 10% lost 1 line. Ultrastructurally, surface irregularity was primarily caused by tissue bridges. The average surface regularity score obtained was 10.87 6 2.40 for 120 mu m, 10.78 +/- 2.60 for 130 mu m, 8.76 +/- 2.16 for 140 mu m, and 8.70 +/- 2.66 for 150 mu m (P, 0.001). The total number and areas of tissue bridges of 120 to 130 mu m were significantly less than 140 to 150 mu m (P < 0.05). Surface regularity decreased as cap thickness increased (P < 0.05). Conclusions: There is smoother appearance of the lenticular surface as seen through SEM when a thin cap is created compared with a thick cap qualitatively and quantitatively.
引用
收藏
页码:59 / 65
页数:7
相关论文
共 50 条
  • [21] Blood clot stabilization after different mechanical and chemical root treatments: a morphological evaluation using scanning electron microscopy
    Stefanini, Martina
    Ceraolo, Edoardo
    Mazzitelli, Claudia
    Maravic, Tatjana
    Sangiorgi, Matteo
    Zucchelli, Giovanni
    Breschi, Lorenzo
    Mazzoni, Annalisa
    JOURNAL OF PERIODONTAL AND IMPLANT SCIENCE, 2022, 52 (01): : 54 - 64
  • [22] Evaluation of Wide Corneal Epithelial Remodeling after Small Incision Lenticule Extraction (SMILE) with Wide-Field Optical Coherence Tomography
    Ye, Yiming
    Chen, Pei
    Yu, Na
    Wan, Linxi
    Lan, Min
    Zheng, Hua
    Yu, Keming
    JOURNAL OF OPHTHALMOLOGY, 2022, 2022
  • [23] Morphological characterization of different human cervical mucus types using light and scanning electron microscopy
    Menárguez, M
    Pastor, LM
    Odeblad, E
    HUMAN REPRODUCTION, 2003, 18 (09) : 1782 - 1789
  • [24] COMPARISON OF DIFFERENT DRYING PROCEDURES FOR SCANNING ELECTRON-MICROSCOPY USING HUMAN-LEUKOCYTES
    TINGBEALL, HP
    ZHELEV, DV
    HOCHMUTH, RM
    MICROSCOPY RESEARCH AND TECHNIQUE, 1995, 32 (04) : 357 - 361
  • [25] Evaluation of enamel loss by scanning electron microscopy after debonding brackets place with four different adhesives
    Rodriguez-Chavez, Jacqueline Adelina
    Arenas-Alatorre, Jesus Angel
    Flores-Ruiz, Hugo M.
    Flores-Ledesma, Abigailt
    Aguilar-Perez, Fernando Javier
    MICROSCOPY RESEARCH AND TECHNIQUE, 2021, 84 (05) : 912 - 920
  • [26] THE CHARACTERIZATION OF FRAGMENTS FROM ELECTRIC BLASTING CAP AFTER DETONATION BY SCANNING ELECTRON-MICROSCOPY
    UEYAMA, M
    ISHIYAMA, I
    FORENSIC SCIENCE INTERNATIONAL, 1987, 35 (2-3) : 219 - 230
  • [27] SCANNING ELECTRON MICROSCOPY OBSERVATION ON THE DIFFERENT TYPES OF SCAR OF HUMAN BODY
    Tang Shaoming Hao Xinguang CaI Kangrong Liang Jie Jiang YanpingDepartment of Plastic Surgery Zhanjiang Medical College Guangdong China
    广东医科大学学报, 1993, (Z1) : 118 - 118
  • [28] CORNEAL ENDOTHELIAL DAMAGE CAUSED BY DIFFERENT TYPES OF INCISION - A SCANNING ELECTRON-MICROSCOPY STUDY
    KRAUSE, UH
    ALANKO, HI
    ACTA OPHTHALMOLOGICA, 1990, 68 : 29 - 32
  • [29] Corneal high order aberrations and asphericity changes throughout time after femtosecond Small Incision Lenticule Extraction (SMILE) performed at different capdepths
    Rivera, Jose
    Ramirez-Miranda, Arturo
    Mordani, Simran
    Jimenez-Collado, David
    Mendizabal-Velazquez, Alondra
    Morales, Carlos
    Navas, Alejandro
    Valdez, Jorge
    Graue-Hernandez, Enrique
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2023, 64 (08)
  • [30] SCANNING ELECTRON-MICROSCOPY OF CORNEAL INCISIONS USING STEEL, DIAMOND, AND SAPPHIRE BLADES
    VANMETER, WS
    BREEN, C
    HAINSWORTH, DP
    GEISSLER, R
    OPHTHALMIC SURGERY AND LASERS, 1990, 21 (07): : 475 - 480