Posterior Capsule Opacification With Two Hydrophobic Acrylic Intraocular Lenses: 3-Year Results of a Randomized Trial

被引:22
|
作者
Leydolt, Christina [1 ]
Schartmuller, Daniel [1 ]
Schwarzenbacher, Luca [1 ]
Roggla, Veronika [1 ]
Schriefl, Sabine [1 ]
Menapace, Rupert [1 ]
机构
[1] Med Univ Vienna, Dept Ophthalmol, Waehringer Guertel 18-20, A-1090 Vienna, Austria
关键词
OPTIC EDGE DESIGN; CONDUCTIVE KERATOPLASTY; MODERATE HYPEROPIA; EPITHELIAL-CELLS; SILICONE; GLISTENINGS; POLYMETHYLMETHACRYLATE; ACRYSOF; BEND;
D O I
10.1016/j.ajo.2020.04.011
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To compare the incidence and intensity of posterior capsule opacification (PCO) and neodymium- yttrium-aluminum-garnet (Nd:YAG) capsulotomy rates between 2 similar open-loop single-piece hydrophobic acrylic intraocular lenses (IOLs) that differ in the proprietary material characteristics and design features, over a period of 3 years. DESIGN: Randomized, prospective, patient- and examiner-masked clinical trial with intraindividual comparison. METHODS: SETTING: Department of Ophthalmology, Medical University of Vienna, Vienna, Austria. PATIENT POPULATION: Eighty patients (160 eyes) had bilateral cataract surgery and received a Vivinex XY1 IOL in 1 eye and an AcrySof SN60WFIOL in the other eye. OBSERVATION PROCEDURES: Follow-up examinations were performed 3 years after surgery. Digital retroillumination images were taken of each eye. The amount of PCO (score: 0-10) was assessed subjectively at the slit lamp and objectively using automated image analysis software (AQUA). MAIN OUTCOME MEASURE: PCO score (scale, 0-10). RESULTS: The mean objective PCO score of the Vivinex XY1 IOLs was 0.9 +/- 0.8 compared to the PCO score of 1.4 +/- 1.1 for the AcrySof SN60WF IOLs (P < .001). Three years postoperatively, 11.4% of patients had an Nd:YAG capsulotomy in the Vivinex XY1 eye and 18.6% had a capsulotomy in the AcrySof SN60WF eye (P = .23). CONCLUSION: The new hydrophobic acrylic Vivinex XY1 IOL showed significantly lower PCO rates and lower YAG rates compared to the AcrySof SN60WF IOL. The interaction of various factors such as hydrophobic material, smooth optic surface, and sharp posterior optic edge plays a key role in PCO development. (C) 2020 The Authors. Published by Elsevier Inc.
引用
收藏
页码:224 / 231
页数:8
相关论文
共 50 条
  • [41] The effectiveness of Nd:YAG laser capsulotomy for the treatment of posterior capsule opacification in children with acrylic intraocular lenses
    Stager, DR
    Wang, XH
    Weakley, DR
    Felius, J
    JOURNAL OF AAPOS, 2006, 10 (02): : 159 - 163
  • [42] Posterior capsule opacification after implantation of a hydrophilic or a hydrophobic acrylic intraocular lens -: One-year follow-up
    Kugelberg, Maria
    Wejde, Gisela
    Jayaram, Hari
    Zetterstrom, Charlotta
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2006, 32 (10): : 1627 - 1631
  • [43] Effect of intraocular lens asphericity on posterior capsule opacification between two intraocular lenses with same acrylic material: a fellow-eye study
    Nanavaty, Mayank A.
    Spalton, David J.
    Gala, Kavita B.
    Dhital, Anish
    Boyce, James
    ACTA OPHTHALMOLOGICA, 2012, 90 (02) : e104 - e108
  • [44] INCIDENCE OF POSTERIOR CAPSULE OPACIFICATION IN EYES WITH AND WITHOUT POSTERIOR CHAMBER INTRAOCULAR LENSES
    NISHI, O
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1986, 12 (05): : 519 - 522
  • [45] Changes in Opacification of Hydrophobic Acrylic Intraocular Lenses According to Temperature and Hydration
    Kang, Jung Youb
    Song, Ju Hwan
    Lee, Sang Joon
    CLINICAL OPHTHALMOLOGY, 2020, 14 : 3343 - 3349
  • [46] Effect of optic material on posterior capsule opacification in intraocular lenses with sharp-edge optics - Randomized clinical trial
    Findl, O
    Menapace, R
    Sacu, S
    Buehl, W
    Rainer, G
    OPHTHALMOLOGY, 2005, 112 (01) : 67 - 72
  • [47] Posterior capsule opacification rate after phacoemulsification in pediatric cataract: Hydrophilic versus hydrophobic intraocular lenses
    Sen, Pradhnya
    Kshetrapal, Mansi
    Shah, Chintan
    Mohan, Amit
    Jain, Elesh
    Sen, Alok
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2019, 45 (10): : 1380 - 1385
  • [48] Capsular bag stability and posterior capsule opacification of a plate-haptic design microincision cataract surgery intraocular lens: 3-year results of a randomised trial
    Hirnschall, Nino
    Nishi, Yutaro
    Crnej, Alja
    Koshy, John
    Gangwani, Vinod
    Maurino, Vincenzo
    Findl, Oliver
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2013, 97 (12) : 1565 - 1568
  • [49] Quantification of posterior capsule opacification with round and sharp edge intraocular lenses
    Auffarth, GU
    Golescu, A
    Becker, KA
    Völcker, HE
    OPHTHALMOLOGY, 2003, 110 (04) : 772 - 780
  • [50] Morphological evaluation of posterior capsule opacification in diffractive multifocal intraocular lenses
    Auffarth, GU
    Neubert, R
    Wang, L
    Hunold, W
    OPHTHALMOLOGE, 2001, 98 (02): : 138 - 142