Posterior Capsule Opacification With Two Hydrophobic Acrylic Intraocular Lenses: 3-Year Results of a Randomized Trial

被引:22
|
作者
Leydolt, Christina [1 ]
Schartmuller, Daniel [1 ]
Schwarzenbacher, Luca [1 ]
Roggla, Veronika [1 ]
Schriefl, Sabine [1 ]
Menapace, Rupert [1 ]
机构
[1] Med Univ Vienna, Dept Ophthalmol, Waehringer Guertel 18-20, A-1090 Vienna, Austria
关键词
OPTIC EDGE DESIGN; CONDUCTIVE KERATOPLASTY; MODERATE HYPEROPIA; EPITHELIAL-CELLS; SILICONE; GLISTENINGS; POLYMETHYLMETHACRYLATE; ACRYSOF; BEND;
D O I
10.1016/j.ajo.2020.04.011
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To compare the incidence and intensity of posterior capsule opacification (PCO) and neodymium- yttrium-aluminum-garnet (Nd:YAG) capsulotomy rates between 2 similar open-loop single-piece hydrophobic acrylic intraocular lenses (IOLs) that differ in the proprietary material characteristics and design features, over a period of 3 years. DESIGN: Randomized, prospective, patient- and examiner-masked clinical trial with intraindividual comparison. METHODS: SETTING: Department of Ophthalmology, Medical University of Vienna, Vienna, Austria. PATIENT POPULATION: Eighty patients (160 eyes) had bilateral cataract surgery and received a Vivinex XY1 IOL in 1 eye and an AcrySof SN60WFIOL in the other eye. OBSERVATION PROCEDURES: Follow-up examinations were performed 3 years after surgery. Digital retroillumination images were taken of each eye. The amount of PCO (score: 0-10) was assessed subjectively at the slit lamp and objectively using automated image analysis software (AQUA). MAIN OUTCOME MEASURE: PCO score (scale, 0-10). RESULTS: The mean objective PCO score of the Vivinex XY1 IOLs was 0.9 +/- 0.8 compared to the PCO score of 1.4 +/- 1.1 for the AcrySof SN60WF IOLs (P < .001). Three years postoperatively, 11.4% of patients had an Nd:YAG capsulotomy in the Vivinex XY1 eye and 18.6% had a capsulotomy in the AcrySof SN60WF eye (P = .23). CONCLUSION: The new hydrophobic acrylic Vivinex XY1 IOL showed significantly lower PCO rates and lower YAG rates compared to the AcrySof SN60WF IOL. The interaction of various factors such as hydrophobic material, smooth optic surface, and sharp posterior optic edge plays a key role in PCO development. (C) 2020 The Authors. Published by Elsevier Inc.
引用
收藏
页码:224 / 231
页数:8
相关论文
共 50 条
  • [22] Posterior Capsule Opacification and Nd:YAG Rates with Two Acrylic Intraocular Lenses after Age-Related Cataract Treatment: Three-year Results
    Kalauz, Miro
    Masnec, Sanja
    Kordic, Rajko
    Kuzman, Tomislav
    Vidas, Sania
    Skegro, Ivan
    Jandrokovic, Sonja
    Peric, Sanja
    SEMINARS IN OPHTHALMOLOGY, 2018, 33 (03) : 395 - 401
  • [23] Posterior capsule opacification with AcrySof and poly(methyl methacrylate) intraocular lenses -: Comparative study with a 3-year follow-up
    Sundelin, K
    Friberg-Riad, Y
    Östberg, A
    Sjöstrand, J
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2001, 27 (10): : 1586 - 1590
  • [24] Posterior Capsule Opacification in Silicone and Hydrophobic Acrylic Intraocular Lenses with Sharp-edge Optics Six Years After Surgery
    Vock, Lorenz
    Crnej, Alia
    Findl, Oliver
    Neumayer, Thomas
    Buehl, Wolf
    Sacu, Stefan
    Rainer, Georg
    Menapace, Rupert
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2009, 147 (04) : 683 - 690
  • [25] Relationship of AcrySof acrylic and PhacoFlex silicone intraocular lenses to visual acuity and posterior capsule opacification
    Halpern, MT
    Covert, D
    Battista, C
    Weinstein, AJ
    Levinson, RD
    Yan, L
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2002, 28 (04): : 662 - 669
  • [26] Analysis of cytoskeletal proteins in posterior capsule opacification after implantation of acrylic and hydrogel intraocular lenses
    Matsushima, H
    Mukai, K
    Obara, Y
    Yoshida, S
    Clark, JI
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2004, 30 (01): : 187 - 194
  • [27] Intraocular Lens and Capsule Opacification with Hydrophilic and Hydrophobic Acrylic Materials
    Saeed, Muhammad Usman
    Jafree, Afsar Jalil
    Saeed, Mohammad Salman
    Zia, Rashid
    Sheikh, Ijaz Mehmood
    Heravi, Mohammad
    SEMINARS IN OPHTHALMOLOGY, 2012, 27 (1-2) : 15 - 18
  • [28] Posterior capsule opacification in rabbits with intraocular lenses made of hydrogel and hydrophobic materials; A comparative study
    Fujiwara, E
    Tahi, H
    Fernandez, V
    Rosa, R
    Parel, JM
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2000, 41 (04) : S485 - S485
  • [29] Hydrophobic versus hydrophilic acrylic intraocular lens on posterior capsule opacification: a Meta-analysis
    Qiong Wu
    Yan Li
    Lian Wu
    Cong-Yi Wang
    International Journal of Ophthalmology, 2022, (06) : 997 - 1004
  • [30] Comparison of posterior capsular opacification in heparin-surface-modified hydrophilic acrylic and hydrophobic acrylic intraocular lenses
    Kang, Seungbum
    Choi, Jin A.
    Joo, Choun-Ki
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 2009, 53 (03) : 204 - 208