Automatic Generation of Bi-Ventricular Models of Cardiac Electrophysiology for Patient Specific Personalization Using Non-Invasive Recordings

被引:7
|
作者
Gillette, Karli [1 ]
Prassl, Anton [1 ]
Bayer, Jason [2 ]
Vigmond, Edward [2 ]
Neic, Aurel [1 ]
Plank, Gernot [1 ]
机构
[1] Med Univ Graz, Inst Biophys, Harrachgasse 21, A-8010 Graz, Austria
[2] Bordeaux Fdn, LIRYC Electrophysiol & Heart Modeling Inst, Pessac, France
关键词
HEART;
D O I
10.22489/CinC.2018.265
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Introduction: Personalized in silico models of cardiac electrophysiology based on non-invasive recordings, such as body surface potential maps, are considered of pivotal importance in clinical modeling applications. Efficient, automated workflows are desired to construct patient-specific models for clinical use. Objective: We aimed to develop an automated workflow for the generation of a parameterizable cardiac EP model capable of simulating body surface potential maps independent of user interaction. Methods: A cardiac bi-ventricular model with torso was segmented and meshed from clinical MRI scans. Universal ventricular coordinates were computed for user-independent definition of fibers, a fast conducting endocardial layer, and earliest activation on the endocardium. The extracellular epicardial potential distribution was simulated and projected to the torso surface to acquire a body surface potential map. Results: Total model generation from segmentation required approximately 2 hours. Automatized simulation of a single depolarization sequence required approximately 30 minutes using a forward element method implementation. Discussion: The proposed workflow integrated recently-developed technologies to generate a parameterizable cardiac EP model within clinical time scales.
引用
收藏
页数:4
相关论文
共 30 条
  • [21] Patient-specific non-invasive estimation of pressure gradient across aortic coarctation using magnetic resonance imaging
    Shi, Yubing
    Valverde, Israel
    Lawford, Patricia V.
    Beerbaum, Philipp
    Hose, D. Rodney
    JOURNAL OF CARDIOLOGY, 2019, 73 (06) : 544 - 552
  • [22] NON-INVASIVE DETERMINATION OF CARDIAC OUTPUT BY THE INERT GAS REBREATHING METHOD IN A PATIENT WITH AN AXIAL-FLOW LEFT-VENTRICULAR ASSIST DEVICE
    Saur, Joachim
    Trinkmann, Frederik
    Hoffmann, Ursula
    Kaden, Jens J.
    Haghi, Dariusch
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2009, 28 (05): : 533 - 534
  • [23] Generation of Patient Specific Cardiac Chamber Models Using Generative Neural Networks Under a Bayesian Framework for Electroanatomical Mapping
    Mathew, Sunil
    Sra, Jasbir
    Rowe, Daniel B.
    JOURNAL OF STATISTICAL THEORY AND PRACTICE, 2025, 19 (01)
  • [24] ROLE OF NON-INVASIVE LEFT VENTRICULAR PRESSURE-STRAIN LOOP TO PREDICT CARDIAC DEATH AND ARRHYTHMIC RISK IN PATIENT WITH ORGANIC HEART DISEASE AND REDUCED LEFT VENTRICULAR EJECTION FRACTION
    Previtero, Marco
    Azzolina, Danila
    Palermo, Chiara
    Tenaglia, Rosaria M.
    Sammarco, Giuseppe
    Ruozi, Niccolo
    Aruta, Patrizia
    Iliceto, Sabino
    Muraru, Denisa
    Badano, Luigi
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2019, 73 (09) : 1625 - 1625
  • [25] A NON-INVASIVE METHOD TO RECONSTRUCT PATIENT-SPECIFIC HUMAN FEMUR WITH IN-SITU DRILLING TEMPERATURE DATA USING PROBABILITY DENSITY FUNCTION
    Pandithevan, Ponnusamy
    Prasannavenkadesan, Varatharajan
    JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY, 2024, 24 (01)
  • [26] Non-Invasive Quantification of Layer-Specific Intrinsic Fluorescence From Mucosa of the Uterine Cervix Using Monte-Carlo-Based Models
    Lin, Guo-Sheng
    Tu, Shih-Cheng
    Mok, Chong-Ian
    Huang, Tsan-Hsueh
    Chen, Chi-Hau
    Wei, Lin-Hung
    Sung, Kung-Bin
    FRONTIERS IN PHYSICS, 2022, 10
  • [27] Non-Invasive Quantification of Layer-Specific Intrinsic Fluorescence From Mucosa of the Uterine Cervix Using Monte-Carlo-Based Models
    Lin, Guo-Sheng
    Tu, Shih-Cheng
    Mok, Chong-Ian
    Huang, Tsan-Hsueh
    Chen, Chi-Hau
    Wei, Lin-Hung
    Sung, Kung-Bin
    Frontiers in Physics, 2022, 10
  • [28] 3.6: Non-Invasive, Mri-Based Estimation of Patient-Specific Aortic Blood Pressure Using One-Dimensional Blood Flow Modelling
    Jorge Mariscal Harana
    Arna van Engelen
    Torben Schneider
    Mateusz Florkow
    Peter Charlton
    Bram Ruijsink
    Hubrecht De Bliek
    Israel Valverde
    Marietta Carakida
    Kuberan Pushparajah
    Spencer Sherwin
    Rene Botnar
    Jordi Alastruey
    Artery Research, 2017, 20 (1) : 54 - 55
  • [29] Spatial Accuracy of Non-Invasive Activation Mapping Modalities for Complex Ventricular Arrhythmias: A Direct Comparison of Electromechanical Wave Imaging ( EWI) Using High Frame Rate Transthoracic Echocardiography and Electrocardiographic Imaging (ECGi) With Cardiac CT
    Tonko, Johanna
    Tourni, Melina
    Konofagou, Elisa
    Lambiase, Pier
    CIRCULATION, 2023, 148
  • [30] Using new non-invasive quick method to detect Borrelia Burgdorferi (BB) infection from specific parts of the heart in "seemingly normal" ECGs, and from the ECGs of Atrial Fibrillation (AF), a majority of AF ECGs are found to have: 1) Significant BB infection, 2) Markedly increased ANP, 3) Increased Cardiac Troponin I & 4) Markedly reduced Taurine. These 4 factors were mainly localized at infected areas of the SA node area, R-&L-Atria & pulmonary veins at the L-atrium.
    Omura, Yoshiaki
    Lu, Dominic
    Jones, Marilyn K.
    Nihrane, Abdallah
    Duvvi, Harsha
    Yapor, Dario
    Shimotsuura, Yasuhiro
    Ohki, Motomu
    ACUPUNCTURE & ELECTRO-THERAPEUTICS RESEARCH, 2015, 40 (04) : 297 - 333