NON-INVASIVE DETERMINATION OF CARDIAC OUTPUT BY THE INERT GAS REBREATHING METHOD IN A PATIENT WITH AN AXIAL-FLOW LEFT-VENTRICULAR ASSIST DEVICE

被引:4
|
作者
Saur, Joachim [1 ]
Trinkmann, Frederik [1 ]
Hoffmann, Ursula [1 ]
Kaden, Jens J. [1 ]
Haghi, Dariusch [1 ]
机构
[1] Univ Hosp, Dept Med 1, Mannheim, Germany
来源
关键词
D O I
10.1016/j.healun.2009.02.010
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
引用
收藏
页码:533 / 534
页数:2
相关论文
共 50 条
  • [1] Correlation of Non-Invasive Flow Estimation of the Axial-Flow Left Ventricular Assist Device with Fick and Thermal Cardiac Output
    Raje, V.
    Mankad, A. K.
    [J]. JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2016, 35 (04): : S386 - S386
  • [2] THE HEMOPUMP - A TRANSVALVULAR, AXIAL-FLOW, LEFT-VENTRICULAR ASSIST DEVICE
    SMALLING, RW
    [J]. CORONARY ARTERY DISEASE, 1991, 2 (06) : 667 - 671
  • [3] The impact of pulmonary parameters on non-invasive measurement of cardiac output by the inert gas rebreathing method
    Saur, J.
    Trinkmann, F.
    Doesch, C.
    Papavassiliu, T.
    Scherhag, A.
    Schoenberg, S. O.
    Borggrefe, M.
    Kaden, J. J.
    [J]. EUROPEAN HEART JOURNAL, 2009, 30 : 595 - 596
  • [4] Non-Invasive Assessment of Cardiac Output in Fibrotic Lung Disease Using an Inert Gas Rebreathing Device
    Corte, T. J.
    Wort, S. J.
    Ward, S.
    Cramer, D.
    Devaraj, A.
    Wells, A. U.
    [J]. AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2009, 179
  • [5] NON-INVASIVE ASSESSMENT OF CARDIAC OUTPUT USING AN INERT GAS REBREATHING DEVICE: REPEATABILITY AND REPRODUCIBILITY IN NORMAL CONTROLS
    Corte, T. J.
    Wort, S. J.
    Ward, S.
    Cramer, D.
    Wells, A. U.
    [J]. THORAX, 2008, 63 : A127 - A127
  • [6] NON-INVASIVE ASSESSMENT OF CARDIAC OUTPUT USING AN INERT GAS REBREATHING DEVICE IN PATIENTS WITH FIBROTIC LUNG DISEASE
    Corte, T. J.
    Wort, S. J.
    Ward, S.
    Cramer, D.
    Devaraj, A.
    Wells, A. U.
    [J]. THORAX, 2008, 63 : A134 - A134
  • [7] Non-invasive determination of cardiac output: Comparison of a novel CW Doppler ultrasonic technique and inert gas rebreathing
    Saur, Joachim
    Trinkmann, Frederik
    Weissmann, Joerg
    Borggrefe, Martin
    Kaden, Jens J.
    [J]. INTERNATIONAL JOURNAL OF CARDIOLOGY, 2009, 136 (02) : 248 - 250
  • [8] Non-invasive measurements of cardiac output in atrial fibrillation: Inert gas rebreathing and impedance cardiography
    Osbak, Philip S.
    Henriksen, Jens H.
    Kofoed, Klaus F.
    Jensen, Gorm B.
    [J]. SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 2011, 71 (04): : 304 - 313
  • [9] A comparative evaluation of electrical velocimetry and inert gas rebreathing for the non-invasive assessment of cardiac output
    Frederik Trinkmann
    Manuel Berger
    Ursula Hoffmann
    Martin Borggrefe
    Jens J. Kaden
    Joachim Saur
    [J]. Clinical Research in Cardiology, 2011, 100
  • [10] A comparative evaluation of electrical velocimetry and inert gas rebreathing for the non-invasive assessment of cardiac output
    Trinkmann, Frederik
    Berger, Manuel
    Hoffmann, Ursula
    Borggrefe, Martin
    Kaden, Jens J.
    Saur, Joachim
    [J]. CLINICAL RESEARCH IN CARDIOLOGY, 2011, 100 (10) : 935 - 943