Novel design of a personnel safety system for Hefei Light Source-II

被引:4
|
作者
Huang, Zi-Yu [1 ]
Xuan, Ke [1 ]
Li, Chuan [1 ]
Wang, Ji-Gang [1 ]
Liu, Gong-Fa [1 ]
机构
[1] Univ Sci & Technol China, Natl Synchrotron Radiat Lab, Hefei 230029, Anhui, Peoples R China
基金
中国国家自然科学基金;
关键词
Personnel safety system; Personnel management; Redundant programmable logic controller; PROFINET; Experimental Physics and Industrial Control System; EPICS;
D O I
10.1007/s41365-019-0610-6
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The Hefei Light Source-II (HLS-II) is a vacuum ultraviolet synchrotron light source. The personnel safety system (PSS), which is a personnel access control system, is a crucial part of the HLS-II, as it protects the staff and users at HLS-II from radiation damages. The prior version of HLS-II PSS was based on an access control system called SiPass. This lacked the personnel management function. Meanwhile, as the prior PSS is a turn-key system, it was not effective for sharing information. To overcome these drawbacks, the novel design of PSS for HLS-II is proposed based on the Siemens redundant programmable logic controller under the Experimental Physics and Industrial Control System. The proposed PSS consists of a safety interlock system, access control system, and a radiation monitoring system. The safety interlock system is used to define the interlock logic. The access control system is designed to restrict the access of staff and users at HLS-II, and to provide a personnel management function. The radiation monitoring system is used to monitor the radiation dose rate in both the light source and the surrounding areas. This paper details the architecture and the specific design of the novel PSS. The off-line test results demonstrate that the proposed system has achieved the design objectives.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Correction to: Research on tune feedback of the Hefei Light Source II based on machine learning
    Yong-Bo Yu
    Gong-Fa Liu
    Wei Xu
    Chuan Li
    Wei-Min Li
    Ke Xuan
    [J]. Nuclear Science and Techniques, 2022, 33
  • [22] Initial Application of Machine Learning for Beam Parameter Optimization at the Hefei Light Source II
    Yu, Yongbo
    Ni, Wangbiao
    Liu, Gongfa
    Xu, Wei
    Li, Chuan
    Li, Weiming
    Xuan, Ke
    [J]. IPAC23 PROCEEDINGS, 2024, 2687
  • [23] Measurement of coherence length and incoherent source size of hard x-ray undulator beamline at Pohang Light Source-II
    Park, So Yeong
    Hong, Chung Ki
    Lim, Jun
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2014, 85 (04):
  • [24] Development of New S-band RF window for S-band RF system of Pohang Light Source-II Linear Accelerator
    Joo, Youngdo
    Hwang, Woonha
    Kim, Seung-Hwan
    Lee, Byung-Joon
    [J]. 2015 IEEE INTERNATIONAL VACUUM ELECTRONICS CONFERENCE (IVEC), 2015,
  • [25] Multimodal X-ray probe station at 9C beamline of Pohang Light Source-II
    Ham, Daseul
    Lee, Su Yong
    Choi, Sukjune
    Oh, Ho Jun
    Noh, Do Young
    Kang, Hyon Chol
    [J]. Journal of Synchrotron Radiation, 2022, 29 : 1114 - 1121
  • [26] Observation of the Talbot Effect at Beamline 6C Bio Medical Imaging of the Pohang Light Source-II
    Youngju Kim
    Seung Wook Lee
    Jae-Hong Lim
    [J]. Journal of the Korean Physical Society, 2019, 74 : 935 - 940
  • [27] Observation of the Talbot Effect at Beamline 6C Bio Medical Imaging of the Pohang Light Source-II
    Kim, Youngju
    Lee, Seung Wook
    Lim, Jae-Hong
    [J]. JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2019, 74 (10) : 935 - 940
  • [28] Development and application of the new BPM system data processing program at Hefei light source
    MA Tianji YANG Yongliang SUN Baogen * ZOU Junying LU Ping ZHOU Zeran XU Hongliang NSRL
    [J]. Nuclear Science and Techniques, 2012, 23 (05) : 261 - 266
  • [29] Development and application of the new BPM system data processing program at Hefei light source
    Ma Tianji
    Yang Yongliang
    Sun Baogen
    Zou Junying
    Lu Ping
    Zhou Zeran
    Xu Hongliang
    [J]. NUCLEAR SCIENCE AND TECHNIQUES, 2012, 23 (05) : 261 - 266
  • [30] Application of Libera Photon in photon beam position measurement system at Hefei light source
    Gu, Li-Ming
    Sun, Bao-Gen
    Yang, Yong-Liang
    Lu, Ping
    Xiao, Yun-Yun
    Wang, Ji-Gang
    Tang, Lei-Lei
    [J]. Yuanzineng Kexue Jishu/Atomic Energy Science and Technology, 2012, 46 (12): : 1512 - 1516