MetICA: independent component analysis for high-resolution mass-spectrometry based non-targeted metabolomics

被引:17
|
作者
Liu, Youzhong [1 ,2 ]
Smirnov, Kirill [1 ]
Lucio, Marianna [1 ]
Gougeon, Regis D. [2 ]
Alexandre, Herve [2 ]
Schmitt-Kopplin, Philippe [1 ,3 ]
机构
[1] Helmholtz Zentrum Munchen, Dept Environm Sci, Res Unit Analyt BioGeoChem, Ingolstadter Landstr 1, D-85758 Neuherberg, Germany
[2] UMR PAM Univ Bourgogne, Inst Univ Vigne & Vin, Agrosup Dijon, Rue Claude Ladrey,BP 27877, Dijon, France
[3] Tech Univ Munich, Chair Analyt Food Chem, Alte Akad 1085354, Freising Weihenstephan, Germany
来源
BMC BIOINFORMATICS | 2016年 / 17卷
关键词
VISUALIZATION; EXPRESSION; CLASSIFICATION; ALGORITHM; SPECTRA;
D O I
10.1186/s12859-016-0970-4
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Background: Interpreting non-targeted metabolomics data remains a challenging task. Signals from non-targeted metabolomics studies stem from a combination of biological causes, complex interactions between them and experimental bias/noise. The resulting data matrix usually contain huge number of variables and only few samples, and classical techniques using nonlinear mapping could result in computational complexity and overfitting. Independent Component Analysis (ICA) as a linear method could potentially bring more meaningful results than Principal Component Analysis (PCA). However, a major problem with most ICA algorithms is the output variations between different runs and the result of a single ICA run should be interpreted with reserve. Results: ICA was applied to simulated and experimental mass spectrometry (MS)-based non-targeted metabolomics data, under the hypothesis that underlying sources are mutually independent. Inspired from the Icasso algorithm, a new ICA method, MetICA was developed to handle the instability of ICA on complex datasets. Like the original Icasso algorithm, MetICA evaluated the algorithmic and statistical reliability of ICA runs. In addition, MetICA suggests two ways to select the optimal number of model components and gives an order of interpretation for the components obtained. Conclusions: Correlating the components obtained with prior biological knowledge allows understanding how nontargeted metabolomics data reflect biological nature and technical phenomena. We could also extract mass signals related to this information. This novel approach provides meaningful components due to their independent nature. Furthermore, it provides an innovative concept on which to base model selection: that of optimizing the number of reliable components instead of trying to fit the data. The current version of MetICA is available at https://github.com/daniellyz/MetICA.
引用
收藏
页数:14
相关论文
共 50 条
  • [31] High-resolution mass-spectrometry analysis of peptides and proteins
    Nikolaev, E. N.
    Popov, I. A.
    Kononikhin, A. S.
    Indeykina, M. I.
    Kukaev, E. N.
    RUSSIAN CHEMICAL REVIEWS, 2012, 81 (11) : 1051 - 1070
  • [32] Non-targeted analysis of tea by hydrophilic interaction liquid chromatography and high resolution mass spectrometry
    Fraser, Karl
    Harrison, Scott J.
    Lane, Geoff A.
    Otter, Don E.
    Hemar, Yacine
    Quek, Siew-Young
    Rasmussen, Susanne
    FOOD CHEMISTRY, 2012, 134 (03) : 1616 - 1623
  • [33] HIGH-RESOLUTION LASER MASS-SPECTROMETRY
    NEUSSER, HJ
    BOESL, U
    WEINKAUF, R
    SCHLAG, EW
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1984, 60 (SEP): : 147 - 156
  • [34] The potential of ion mobility-mass spectrometry for non-targeted metabolomics
    Mairinger, Teresa
    Causon, Tim J.
    Hann, Stephan
    CURRENT OPINION IN CHEMICAL BIOLOGY, 2018, 42 : 9 - 15
  • [35] CHOOSING BETWEEN HIGH-RESOLUTION MASS-SPECTROMETRY AND MASS-SPECTROMETRY MASS-SPECTROMETRY - ENVIRONMENTAL APPLICATIONS
    CHARLES, MJ
    TONDEUR, Y
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1990, 24 (12) : 1856 - 1860
  • [36] Non-targeted screening workflows for gas chromatography–high-resolution mass spectrometry analysis and identification of biomagnifying contaminants in biota samples
    Andriy Rebryk
    Peter Haglund
    Analytical and Bioanalytical Chemistry, 2021, 413 : 479 - 501
  • [37] Dual column chromatography combined with high-resolution mass spectrometry improves coverage of non-targeted analysis of plant root exudates
    Bennett, Alexandra A.
    Steininger-Mairinger, Teresa
    Eroglu, Cagla Gorkem
    Gfeller, Aurelie
    Wirth, Judith
    Puschenreiter, Markus
    Hann, Stephan
    ANALYTICA CHIMICA ACTA, 2024, 1327
  • [38] Online and Offline Prioritization of Chemicals of Interest in Suspect Screening and Non-targeted Screening with High-Resolution Mass Spectrometry
    Szabo, Drew
    Falconer, Travis M.
    Fisher, Christine M.
    Heise, Ted
    Phillips, Allison L.
    Vas, Gyorgy
    Williams, Antony J.
    Kruve, Anneli
    ANALYTICAL CHEMISTRY, 2024, 96 (09) : 3707 - 3716
  • [39] Assessing Reliability of Non-targeted High-Resolution Mass Spectrometry Fingerprints for Quantitative Source Apportionment in Complex Matrices
    Peter, Katherine T.
    Kolodziej, Edward P.
    Kucklick, John R.
    ANALYTICAL CHEMISTRY, 2022, 94 (06) : 2723 - 2731
  • [40] Comparison of data acquisition modes with Orbitrap high-resolution mass spectrometry for targeted and non-targeted residue screening in aquacultured eel
    Wu, I-Lin
    Turnipseed, Sherri B.
    Storey, Joseph M.
    Andersen, Wendy C.
    Madson, Mark R.
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2020, 34 (07)