MetICA: independent component analysis for high-resolution mass-spectrometry based non-targeted metabolomics

被引:17
|
作者
Liu, Youzhong [1 ,2 ]
Smirnov, Kirill [1 ]
Lucio, Marianna [1 ]
Gougeon, Regis D. [2 ]
Alexandre, Herve [2 ]
Schmitt-Kopplin, Philippe [1 ,3 ]
机构
[1] Helmholtz Zentrum Munchen, Dept Environm Sci, Res Unit Analyt BioGeoChem, Ingolstadter Landstr 1, D-85758 Neuherberg, Germany
[2] UMR PAM Univ Bourgogne, Inst Univ Vigne & Vin, Agrosup Dijon, Rue Claude Ladrey,BP 27877, Dijon, France
[3] Tech Univ Munich, Chair Analyt Food Chem, Alte Akad 1085354, Freising Weihenstephan, Germany
来源
BMC BIOINFORMATICS | 2016年 / 17卷
关键词
VISUALIZATION; EXPRESSION; CLASSIFICATION; ALGORITHM; SPECTRA;
D O I
10.1186/s12859-016-0970-4
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Background: Interpreting non-targeted metabolomics data remains a challenging task. Signals from non-targeted metabolomics studies stem from a combination of biological causes, complex interactions between them and experimental bias/noise. The resulting data matrix usually contain huge number of variables and only few samples, and classical techniques using nonlinear mapping could result in computational complexity and overfitting. Independent Component Analysis (ICA) as a linear method could potentially bring more meaningful results than Principal Component Analysis (PCA). However, a major problem with most ICA algorithms is the output variations between different runs and the result of a single ICA run should be interpreted with reserve. Results: ICA was applied to simulated and experimental mass spectrometry (MS)-based non-targeted metabolomics data, under the hypothesis that underlying sources are mutually independent. Inspired from the Icasso algorithm, a new ICA method, MetICA was developed to handle the instability of ICA on complex datasets. Like the original Icasso algorithm, MetICA evaluated the algorithmic and statistical reliability of ICA runs. In addition, MetICA suggests two ways to select the optimal number of model components and gives an order of interpretation for the components obtained. Conclusions: Correlating the components obtained with prior biological knowledge allows understanding how nontargeted metabolomics data reflect biological nature and technical phenomena. We could also extract mass signals related to this information. This novel approach provides meaningful components due to their independent nature. Furthermore, it provides an innovative concept on which to base model selection: that of optimizing the number of reliable components instead of trying to fit the data. The current version of MetICA is available at https://github.com/daniellyz/MetICA.
引用
收藏
页数:14
相关论文
共 50 条
  • [21] A pilot study of non-targeted screening for stimulant misuse using high-resolution mass spectrometry
    de Oliveira Sardela, Patricia Davies
    Sardela, Vinicius Figueiredo
    dos Santos da Silva, Andressa Maia
    Gualberto Pereira, Henrique Marcelo
    de Aquino Neto, Francisco Radler
    FORENSIC TOXICOLOGY, 2019, 37 (02) : 465 - 473
  • [22] Characterization of hallucinogenic phenethylamines using high-resolution mass spectrometry for non-targeted screening purposes
    Pasin, Daniel
    Cawley, Adam
    Bidny, Sergei
    Fu, Shanlin
    DRUG TESTING AND ANALYSIS, 2017, 9 (10) : 1620 - 1629
  • [23] "MS-Ready" structures for non-targeted high-resolution mass spectrometry screening studies
    McEachran, Andrew D.
    Mansouri, Kamel
    Grulke, Chris
    Schymanski, Emma L.
    Ruttkies, Christoph
    Williams, Antony J.
    JOURNAL OF CHEMINFORMATICS, 2018, 10
  • [24] A non-targeted high-resolution mass spectrometry approach for the assessment of the geographical origin of durum wheat
    Cavanna, Daniele
    Loffi, Cecilia
    Dall'Asta, Chiara
    Suman, Michele
    FOOD CHEMISTRY, 2020, 317
  • [25] Non-targeted and targeted analysis of oxylipins in combination with charge-switch derivatization by ion mobility high-resolution mass spectrometry
    Stefan Hellhake
    Sven W. Meckelmann
    Michael T. Empl
    Kristina Rentmeister
    Walter Wißdorf
    Pablo Steinberg
    Oliver J. Schmitz
    Thorsten Benter
    Nils Helge Schebb
    Analytical and Bioanalytical Chemistry, 2020, 412 : 5743 - 5757
  • [26] Non-targeted and targeted analysis of oxylipins in combination with charge-switch derivatization by ion mobility high-resolution mass spectrometry
    Hellhake, Stefan
    Meckelmann, Sven W.
    Empl, Michael T.
    Rentmeister, Kristina
    Wissdorf, Walter
    Steinberg, Pablo
    Schmitz, Oliver J.
    Benter, Thorsten
    Schebb, Nils Helge
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2020, 412 (23) : 5743 - 5757
  • [27] COMPARISON OF HIGH-RESOLUTION MASS-SPECTROMETRY AND MASS-SPECTROMETRY MASS-SPECTROMETRY TECHNIQUES IN THE ANALYSIS OF CHLORINATED DIOXINS FURANS
    LAU, BPY
    WEBER, D
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1988, 195 : 202 - ANYL
  • [28] Non-targeted screening of pesticides for food analysis using liquid chromatography high-resolution mass spectrometry-a review
    Guo, Zeqin
    Zhu, Zhiguo
    Huang, Sheng
    Wang, Jianhua
    FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT, 2020, 37 (07): : 1180 - 1201
  • [29] Parallel targeted and non-targeted quantitative analysis of steroids in human serum and peritoneal fluid by liquid chromatography high-resolution mass spectrometry
    Thomas Andrieu
    Therina du Toit
    Bruno Vogt
    Michael D. Mueller
    Michael Groessl
    Analytical and Bioanalytical Chemistry, 2022, 414 : 7461 - 7472
  • [30] Parallel targeted and non-targeted quantitative analysis of steroids in human serum and peritoneal fluid by liquid chromatography high-resolution mass spectrometry
    Andrieu, Thomas
    du Toit, Therina
    Vogt, Bruno
    Mueller, Michael D.
    Groessl, Michael
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2022, 414 (25) : 7461 - 7472