MetICA: independent component analysis for high-resolution mass-spectrometry based non-targeted metabolomics

被引:17
|
作者
Liu, Youzhong [1 ,2 ]
Smirnov, Kirill [1 ]
Lucio, Marianna [1 ]
Gougeon, Regis D. [2 ]
Alexandre, Herve [2 ]
Schmitt-Kopplin, Philippe [1 ,3 ]
机构
[1] Helmholtz Zentrum Munchen, Dept Environm Sci, Res Unit Analyt BioGeoChem, Ingolstadter Landstr 1, D-85758 Neuherberg, Germany
[2] UMR PAM Univ Bourgogne, Inst Univ Vigne & Vin, Agrosup Dijon, Rue Claude Ladrey,BP 27877, Dijon, France
[3] Tech Univ Munich, Chair Analyt Food Chem, Alte Akad 1085354, Freising Weihenstephan, Germany
来源
BMC BIOINFORMATICS | 2016年 / 17卷
关键词
VISUALIZATION; EXPRESSION; CLASSIFICATION; ALGORITHM; SPECTRA;
D O I
10.1186/s12859-016-0970-4
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Background: Interpreting non-targeted metabolomics data remains a challenging task. Signals from non-targeted metabolomics studies stem from a combination of biological causes, complex interactions between them and experimental bias/noise. The resulting data matrix usually contain huge number of variables and only few samples, and classical techniques using nonlinear mapping could result in computational complexity and overfitting. Independent Component Analysis (ICA) as a linear method could potentially bring more meaningful results than Principal Component Analysis (PCA). However, a major problem with most ICA algorithms is the output variations between different runs and the result of a single ICA run should be interpreted with reserve. Results: ICA was applied to simulated and experimental mass spectrometry (MS)-based non-targeted metabolomics data, under the hypothesis that underlying sources are mutually independent. Inspired from the Icasso algorithm, a new ICA method, MetICA was developed to handle the instability of ICA on complex datasets. Like the original Icasso algorithm, MetICA evaluated the algorithmic and statistical reliability of ICA runs. In addition, MetICA suggests two ways to select the optimal number of model components and gives an order of interpretation for the components obtained. Conclusions: Correlating the components obtained with prior biological knowledge allows understanding how nontargeted metabolomics data reflect biological nature and technical phenomena. We could also extract mass signals related to this information. This novel approach provides meaningful components due to their independent nature. Furthermore, it provides an innovative concept on which to base model selection: that of optimizing the number of reliable components instead of trying to fit the data. The current version of MetICA is available at https://github.com/daniellyz/MetICA.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] MetICA: independent component analysis for high-resolution mass-spectrometry based non-targeted metabolomics
    Youzhong Liu
    Kirill Smirnov
    Marianna Lucio
    Régis D. Gougeon
    Hervé Alexandre
    Philippe Schmitt-Kopplin
    BMC Bioinformatics, 17
  • [2] Non-targeted metabolomics by high resolution mass spectrometry in HPRT knockout mice
    Tschirner, Sarah K.
    Baehre, Heike
    Kaever, Alexander
    Schneider, Erich H.
    Seifert, Roland
    Kaever, Volkhard
    LIFE SCIENCES, 2016, 156 : 68 - 73
  • [3] Approaches for assessing performance of high-resolution mass spectrometry–based non-targeted analysis methods
    Christine M. Fisher
    Katherine T. Peter
    Seth R. Newton
    Andrew J. Schaub
    Jon R. Sobus
    Analytical and Bioanalytical Chemistry, 2022, 414 : 6455 - 6471
  • [4] Non-targeted analysis with high-resolution mass spectrometry for investigation of riverbank filtration processes
    Kutlucinar, Kaan Georg
    Handl, Sebastian
    Allabashi, Roza
    Causon, Tim
    Troyer, Christina
    Mayr, Ernest
    Perfler, Reinhard
    Hann, Stephan
    ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2022, 29 (43) : 64568 - 64581
  • [5] Non-targeted analysis with high-resolution mass spectrometry for investigation of riverbank filtration processes
    Kaan Georg Kutlucinar
    Sebastian Handl
    Roza Allabashi
    Tim Causon
    Christina Troyer
    Ernest Mayr
    Reinhard Perfler
    Stephan Hann
    Environmental Science and Pollution Research, 2022, 29 : 64568 - 64581
  • [6] Approaches for assessing performance of high-resolution mass spectrometry-based non-targeted analysis methods
    Fisher, Christine M.
    Peter, Katherine T.
    Newton, Seth R.
    Schaub, Andrew J.
    Sobus, Jon R.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2022, 414 (22) : 6455 - 6471
  • [7] The chromatographic role in high resolution mass spectrometry for non-targeted analysis
    Croley, Timothy R.
    White, Kevin D.
    Callahan, John H.
    Musser, Steven M.
    Journal of the American Society for Mass Spectrometry, 2012, 23 (09): : 1569 - 1578
  • [8] The Chromatographic Role in High Resolution Mass Spectrometry for Non-Targeted Analysis
    Croley, Timothy R.
    White, Kevin D.
    Callahan, John H.
    Musser, Steven M.
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2012, 23 (09) : 1569 - 1578
  • [9] Non-targeted high-resolution mass spectrometry study for evaluation of milk freshness
    Loffi, Cecilia
    Cavanna, Daniele
    Sammarco, Giuseppe
    Catellani, Dante
    Dall'Asta, Chiara
    Suman, Michele
    JOURNAL OF DAIRY SCIENCE, 2021, 104 (12) : 12286 - 12294
  • [10] CHARACTERIZATION OF CANNABINOIDS USING HIGH-RESOLUTION MASS SPECTROMETRY FOR NON-TARGETED SCREENING
    Pasin, Daniel
    Cawley, Adam
    Bidny, Sergei
    Fu, Shanlin
    FORENSIC SCIENCE INTERNATIONAL, 2017, 277 : 200 - 200