Combined uncertainty estimation for the determination of the dissolved iron amount content in seawater using flow injection with chemiluminescence detection

被引:17
|
作者
Floor, Geerke H. [1 ]
Clough, Robert [2 ]
Lohan, Maeve C. [2 ]
Ussher, Simon J. [2 ]
Worsfold, Paul J. [2 ]
Quetel, Christophe R. [1 ]
机构
[1] Joint Res Ctr European Commiss, Inst Reference Mat & Measurements, Geel, Belgium
[2] Univ Plymouth, Sch Geog Earth & Environm Sci, Biogeochem Res Ctr, Plymouth PL4 8AA, Devon, England
来源
LIMNOLOGY AND OCEANOGRAPHY-METHODS | 2015年 / 13卷 / 12期
基金
英国自然环境研究理事会;
关键词
ATLANTIC; WATERS; TRANSECT; LUMINOL; OCEAN; FE; CO;
D O I
10.1002/lom3.10057
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
This work assesses the components contributing to the combined uncertainty budget associated with the measurement of the Fe amount content by flow injection chemiluminescence (FI-CL) in<0.2 m filtered and acidified seawater samples. Amounts of loaded standard solutions and samples were determined gravimetrically by differential weighing. Up to 5% variations in the loaded masses were observed during measurements, in contradiction to the usual assumptions made when operating under constant loading time conditions. Hence signal intensities (V) were normalised to the loaded mass and plots of average normalised intensities (in V kg(-1)) vs. values of the Fe amount content (in nmol kg(-1)) added to a low level iron seawater matrix were used to produce the calibration graphs. The measurement procedure implemented and the uncertainty estimation process developed were validated from the agreement obtained with consensus values for three SAFe and GEOTRACES reference materials (D2, GS, and GD). Relative expanded uncertainties for peak height and peak area based results were estimated to be around 12% and 10% (coverage factor k=2), respectively. The most important contributory factors were the uncertainty on the sensitivity coefficient (i.e., calibration slope) and the within-sequence-stability (i.e., the signal stability over several hours of operation; here 32 h). For GD, using peak height measurements, these factors contributed respectively 69.7% and 21.6% while the short-term repeatability accounted for only 7.9%. Therefore, an uncertainty estimation based on the intensity repeatability alone, as is often done in FI-CL studies, is not a realistic estimation of the overall uncertainty of the procedure.
引用
收藏
页码:673 / 686
页数:14
相关论文
共 50 条
  • [1] Investigation of iron(III) reduction and trace metal interferences in the determination of dissolved iron in seawater using flow injection with luminol chemiluminescence detection
    Ussher, Simon J.
    Milne, Angela
    Landing, William M.
    Attiq-ur-Rehman, Kakar
    Seguret, Marie J. M.
    Holland, Toby
    Achterberg, Eric P.
    Nabi, Abdul
    Worsfold, Paul J.
    [J]. ANALYTICA CHIMICA ACTA, 2009, 652 (1-2) : 259 - 265
  • [2] DETERMINATION OF SUBNANOMOLAR LEVELS OF IRON(II) AND TOTAL DISSOLVED IRON IN SEAWATER BY FLOW-INJECTION ANALYSIS WITH CHEMILUMINESCENCE DETECTION
    ELROD, VA
    JOHNSON, KS
    COALE, KH
    [J]. ANALYTICAL CHEMISTRY, 1991, 63 (09) : 893 - 898
  • [3] Determination of total dissolved cobalt in UV-irradiated seawater using flow injection with chemiluminescence detection
    Shelley, Rachel U.
    Zachhuber, Bernhard
    Sedwick, Peter N.
    Worsfold, Paul J.
    Lohan, Maeve C.
    [J]. LIMNOLOGY AND OCEANOGRAPHY-METHODS, 2010, 8 : 352 - 362
  • [4] Determination of sub-nanomolar levels of iron in seawater using flow injection with chemiluminescence detection
    Bowie, AR
    Achterberg, EP
    Mantoura, RFC
    Worsfold, PJ
    [J]. ANALYTICA CHIMICA ACTA, 1998, 361 (03) : 189 - 200
  • [5] Determination of copper complexation in seawater using flow injection analysis with chemiluminescence detection
    Zamzow, H
    Coale, KH
    Johnson, KS
    Sakamoto, CM
    [J]. ANALYTICA CHIMICA ACTA, 1998, 377 (2-3) : 133 - 144
  • [6] Determination of iron in blood serum using flow injection with luminol chemiluminescence detection
    Waseem, A
    Yaqoob, M
    Nabi, A
    [J]. LUMINESCENCE, 2004, 19 (06) : 333 - 338
  • [7] UV digestion of seawater samples prior to the determination of copper using flow injection with chemiluminescence detection
    Achterberg, EP
    Braungardt, CB
    Sandford, RC
    Worsfold, PJ
    [J]. ANALYTICA CHIMICA ACTA, 2001, 440 (01) : 27 - 36
  • [8] Determination of methyltestosterone using flow injection with chemiluminescence detection
    Xie, ZH
    Ouyang, XQ
    Guo, LQ
    Lin, XC
    Chen, GN
    [J]. LUMINESCENCE, 2005, 20 (03) : 231 - 235
  • [9] Determination of cobalt and iron in estuarine and coastal waters using flow injection with chemiluminescence detection
    Cannizzaro, V
    Bowie, AR
    Sax, A
    Achterberg, EP
    Worsfold, PJ
    [J]. ANALYST, 2000, 125 (01) : 51 - 57
  • [10] Determination of total and dissolved amount of iron in water samples using catalytic spectrophotometric flow injection analysis
    Lunvongsa, S
    Oshima, M
    Motomizu, S
    [J]. TALANTA, 2006, 68 (03) : 969 - 973