Combined uncertainty estimation for the determination of the dissolved iron amount content in seawater using flow injection with chemiluminescence detection

被引:17
|
作者
Floor, Geerke H. [1 ]
Clough, Robert [2 ]
Lohan, Maeve C. [2 ]
Ussher, Simon J. [2 ]
Worsfold, Paul J. [2 ]
Quetel, Christophe R. [1 ]
机构
[1] Joint Res Ctr European Commiss, Inst Reference Mat & Measurements, Geel, Belgium
[2] Univ Plymouth, Sch Geog Earth & Environm Sci, Biogeochem Res Ctr, Plymouth PL4 8AA, Devon, England
来源
LIMNOLOGY AND OCEANOGRAPHY-METHODS | 2015年 / 13卷 / 12期
基金
英国自然环境研究理事会;
关键词
ATLANTIC; WATERS; TRANSECT; LUMINOL; OCEAN; FE; CO;
D O I
10.1002/lom3.10057
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
This work assesses the components contributing to the combined uncertainty budget associated with the measurement of the Fe amount content by flow injection chemiluminescence (FI-CL) in<0.2 m filtered and acidified seawater samples. Amounts of loaded standard solutions and samples were determined gravimetrically by differential weighing. Up to 5% variations in the loaded masses were observed during measurements, in contradiction to the usual assumptions made when operating under constant loading time conditions. Hence signal intensities (V) were normalised to the loaded mass and plots of average normalised intensities (in V kg(-1)) vs. values of the Fe amount content (in nmol kg(-1)) added to a low level iron seawater matrix were used to produce the calibration graphs. The measurement procedure implemented and the uncertainty estimation process developed were validated from the agreement obtained with consensus values for three SAFe and GEOTRACES reference materials (D2, GS, and GD). Relative expanded uncertainties for peak height and peak area based results were estimated to be around 12% and 10% (coverage factor k=2), respectively. The most important contributory factors were the uncertainty on the sensitivity coefficient (i.e., calibration slope) and the within-sequence-stability (i.e., the signal stability over several hours of operation; here 32 h). For GD, using peak height measurements, these factors contributed respectively 69.7% and 21.6% while the short-term repeatability accounted for only 7.9%. Therefore, an uncertainty estimation based on the intensity repeatability alone, as is often done in FI-CL studies, is not a realistic estimation of the overall uncertainty of the procedure.
引用
收藏
页码:673 / 686
页数:14
相关论文
共 50 条
  • [21] Determination of total iron in fresh water's using flow injection with potassium permanganate chemiluminescence detection
    Yaqoob, M.
    Waseem, A.
    Nabi, A.
    [J]. JOURNAL OF ANALYTICAL CHEMISTRY, 2006, 61 (09) : 917 - 921
  • [22] Determination of tyrosine using flow injection analysis coupled with chemiluminescence detection
    Zhang, XY
    Fan, XD
    Gao, X
    Zhang, FY
    Zhang, Q
    [J]. CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2004, 32 (12) : 1693 - 1693
  • [23] Determination of silicate in freshwaters using flow injection with luminol chemiluminescence detection
    Yaqoob, M
    Nabi, A
    Worsfold, PJ
    [J]. ANALYTICA CHIMICA ACTA, 2004, 519 (02) : 137 - 142
  • [24] Determination of sulphite using an immobilized enzyme with flow injection chemiluminescence detection
    Yaqoob, M
    Nabi, A
    Waseem, A
    Masoom-Yasinzai, M
    [J]. LUMINESCENCE, 2004, 19 (01) : 26 - 30
  • [25] DETERMINATION OF IRON IN SEAWATER BY FLOW INJECTION-ANALYSIS USING IN-LINE PRECONCENTRATION AND SPECTROPHOTOMETRIC DETECTION
    MEASURES, CI
    YUAN, J
    RESING, JA
    [J]. MARINE CHEMISTRY, 1995, 50 (1-4) : 3 - 12
  • [26] Determination of dipyridamole by flow injection analysis with chemiluminescence detection
    Yang, ML
    Li, LQ
    Feng, ML
    Lü, JR
    Zhang, ZJ
    [J]. CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2000, 28 (02) : 161 - 163
  • [27] Flow-injection with chemiluminescence detection for the determination of iproniazid
    Alonso, MCS
    Zamora, LL
    Calatayud, JM
    [J]. ANALYTICA CHIMICA ACTA, 2001, 437 (02) : 225 - 231
  • [28] Determination of carbohydrates by flow injection with direct chemiluminescence detection
    Agater, IB
    Jewsbury, RA
    Williams, K
    [J]. ANALYTICAL COMMUNICATIONS, 1996, 33 (10): : 367 - 369
  • [29] Ethanol determination by the flow injection analysis, with chemiluminescence detection
    Danet, AF
    Badea, M
    Jipa, S
    [J]. REVISTA DE CHIMIE, 1997, 48 (08): : 726 - 731
  • [30] Determination of rutin by flow injection with inhibited chemiluminescence detection
    He, CX
    Cui, H
    Zhao, XY
    Zhao, HZ
    Zhao, GW
    [J]. ANALYTICAL LETTERS, 1999, 32 (14) : 2751 - 2759