Determination of copper complexation in seawater using flow injection analysis with chemiluminescence detection

被引:39
|
作者
Zamzow, H
Coale, KH
Johnson, KS
Sakamoto, CM
机构
[1] Moss Landing Marine Labs, Moss Landing, CA 95039 USA
[2] Monterey Bay Aquarium Res Inst, Moss Landing, CA 95039 USA
关键词
copper; seawater; flow injection analysis; complexation; chemiluminescence;
D O I
10.1016/S0003-2670(98)00618-7
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Flow injection analysis with chemiluminescence detection (FIA-CL) via the reaction of copper with 1,10-phenanthroline was used for the determination of copper complexation in seawater. A detection limit of 0.1 nM Cu in undiluted seawater without sample preconcentration was obtained. Copper speciation was assessed by titrating natural seawater ligands with added copper. This method was used to measure copper complexation throughout the water column in Monterey Bay, California. Two ligand classes were identified: a strong ligand (L-1), ranging in concentration from 1.3 to 3.1 nM, and a weaker ligand (L-2), ranging from 9.4 to 25.6 nM. The average conditional stability constant for the strong ligand was log K-1' 13.1+/-0.4 and for the weaker ligand log K-2' 9.4+/-0.6. These measurements are in good agreement with complexation studies previously performed using established methods. This technique may eventually be adapted for in situ complexation measurements that can be used to monitor natural spatial and temporal variations in copper complexation, as well as coastal ecosystem responses to urban and industrial change. (C) 1998 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:133 / 144
页数:12
相关论文
共 50 条
  • [1] UV digestion of seawater samples prior to the determination of copper using flow injection with chemiluminescence detection
    Achterberg, EP
    Braungardt, CB
    Sandford, RC
    Worsfold, PJ
    [J]. ANALYTICA CHIMICA ACTA, 2001, 440 (01) : 27 - 36
  • [2] Determination of Polyamines by flow injection analysis with a chemiluminescence detector based on their complexation with copper(II)
    Li, Zheng-Ping
    Wu, Qiu-Hua
    Wang, Chun
    Su, Yu-Qin
    [J]. ANALYTICAL SCIENCES, 2006, 22 (05) : 763 - 767
  • [3] Determination of Polyamines by Flow Injection Analysis with a Chemiluminescence Detector Based on Their Complexation with Copper(II)
    Zheng-Ping Li
    Qiu-Hua Wu
    Chun Wang
    Yu-Qin Su
    [J]. Analytical Sciences, 2006, 22 : 763 - 767
  • [4] DETERMINATION OF PICOMOLAR LEVELS OF COBALT IN SEAWATER BY FLOW-INJECTION ANALYSIS WITH CHEMILUMINESCENCE DETECTION
    SAKAMOTOARNOLD, CM
    JOHNSON, KS
    [J]. ANALYTICAL CHEMISTRY, 1987, 59 (14) : 1789 - 1794
  • [5] Determination of tyrosine using flow injection analysis coupled with chemiluminescence detection
    Zhang, XY
    Fan, XD
    Gao, X
    Zhang, FY
    Zhang, Q
    [J]. CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2004, 32 (12) : 1693 - 1693
  • [6] Determination of sub-nanomolar levels of iron in seawater using flow injection with chemiluminescence detection
    Bowie, AR
    Achterberg, EP
    Mantoura, RFC
    Worsfold, PJ
    [J]. ANALYTICA CHIMICA ACTA, 1998, 361 (03) : 189 - 200
  • [7] Determination of methyltestosterone using flow injection with chemiluminescence detection
    Xie, ZH
    Ouyang, XQ
    Guo, LQ
    Lin, XC
    Chen, GN
    [J]. LUMINESCENCE, 2005, 20 (03) : 231 - 235
  • [8] Determination of dipyridamole by flow injection analysis with chemiluminescence detection
    Yang, ML
    Li, LQ
    Feng, ML
    Lü, JR
    Zhang, ZJ
    [J]. CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2000, 28 (02) : 161 - 163
  • [9] Ethanol determination by the flow injection analysis, with chemiluminescence detection
    Danet, AF
    Badea, M
    Jipa, S
    [J]. REVISTA DE CHIMIE, 1997, 48 (08): : 726 - 731
  • [10] Determination of hydroxycamptothecinum by flow injection analysis with chemiluminescence detection
    Li Liqing
    Lin, Guan
    Ming, Su
    Sun Hanwen
    [J]. JOURNAL OF CLINICAL LABORATORY ANALYSIS, 2007, 21 (06) : 356 - 362