Determination of Polyamines by flow injection analysis with a chemiluminescence detector based on their complexation with copper(II)

被引:4
|
作者
Li, Zheng-Ping [1 ]
Wu, Qiu-Hua
Wang, Chun
Su, Yu-Qin
机构
[1] Univ Hebei, Coll Chem & Environm Sci, Baoding 071002, Hebei Prov, Peoples R China
[2] Agr Univ Hebei, Coll Sci, Baoding 071002, Hebei Prov, Peoples R China
关键词
D O I
10.2116/analsci.22.763
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Through the flow injection analysis experiments, we discovered that an unsaturated complex of Cu(II) and polyamines (spermine, spermidine, putrescine) had a strongly catalytic effect on luminol-H2O2 chemiluminescence (CL) reaction, and that the CL intensity is proportional to the concentrations of polyamines. Based on the automatic formation of an unsaturated complex of polyamines and Cu(II) when the solution containing polyamines passed through a column packed with solid Cu(OH)(2), a new flow injection chemiluminescence analysis method was proposed for the determination of polyamines. The effects of pH, buffer concentration, the concentration of chemiluminescence reagent, and the influence of mixing coil length were examined. Under optimal conditions, the linear range was from 1.0 x 10(-7) mol L-1 to 1.0 x 10(-5) mol L-1, and the detection limits were 0.17, 0.38, 0.44 pmol for spermine, spermidine, and putrescine, respectively. Compared with other methods, the advantages of this method include convenience, time-saving and low cost.
引用
收藏
页码:763 / 767
页数:5
相关论文
共 50 条
  • [1] Determination of Polyamines by Flow Injection Analysis with a Chemiluminescence Detector Based on Their Complexation with Copper(II)
    Zheng-Ping Li
    Qiu-Hua Wu
    Chun Wang
    Yu-Qin Su
    [J]. Analytical Sciences, 2006, 22 : 763 - 767
  • [2] Chemiluminescence flow injection determination of copper (II)
    Safavi, A
    Baezzat, MR
    [J]. ANALYTICAL LETTERS, 2000, 33 (04) : 667 - 675
  • [3] Determination of copper complexation in seawater using flow injection analysis with chemiluminescence detection
    Zamzow, H
    Coale, KH
    Johnson, KS
    Sakamoto, CM
    [J]. ANALYTICA CHIMICA ACTA, 1998, 377 (2-3) : 133 - 144
  • [4] Flow injection chemiluminescence for determination of trace copper(II)
    Gao, Weiqiang
    Yan, Mei
    Zhang, Haidong
    Ge, Shenguang
    Yu, Jinhua
    [J]. LUMINESCENCE, 2010, 25 (02) : 124 - 125
  • [5] Determination of cysteine in a pharmaceutical formulation by flow injection analysis with a chemiluminescence detector
    Lau, CW
    Qin, XJ
    Liang, HY
    Lu, HZ
    [J]. ANALYTICA CHIMICA ACTA, 2004, 514 (01) : 45 - 49
  • [6] Determination of ciprofloxacin by flow injection analysis based on chemiluminescence system
    Zhang Zhuoyong
    Li Xia
    Wang Xiaoli
    Chen Shilu
    Song Baohua
    Zhao Huichun
    [J]. JOURNAL OF RARE EARTHS, 2006, 24 (03) : 285 - 288
  • [7] Determination of melamine by flow injection analysis based on chemiluminescence system
    Zeng, Hua-jin
    Yang, Ran
    Wang, Qing-wen
    Li, Jian-jun
    Qu, Ling-bo
    [J]. FOOD CHEMISTRY, 2011, 127 (02) : 842 - 846
  • [8] Determination of Ciprofloxacin by Flow Injection Analysis Based on Chemiluminescence System
    张卓勇
    李夏
    王小丽
    陈世稆
    宋保华
    赵慧春
    [J]. Journal of Rare Earths, 2006, (03) : 285 - 288
  • [9] Flow injection analysis with simple chemiluminescence detector for hypoxanthine
    Yagiuda, K
    Hemmi, A
    Sakamura, K
    Ito, S
    Asano, Y
    Hayashi, K
    Karube, I
    [J]. DENKI KAGAKU, 1995, 63 (12): : 1148 - 1153
  • [10] Determination of paracetamol by flow injection chemiluminescence analysis
    Chen, H
    Zhang, ZJ
    Fu, ZF
    [J]. CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2002, 30 (11) : 1344 - 1347