Horizontally installed cone differential pressure meter wet gas flow performance

被引:39
|
作者
Steven, Richard [1 ]
机构
[1] Multiphase & Wet Gas Flow Res Colorado Engn Exp S, Nunn, CO 80648 USA
关键词
Two phase; Multiphase; Wet gas flow; Cone differential pressure; Venturi meter;
D O I
10.1016/j.flowmeasinst.2008.06.002
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Differential pressure (DP) meters which utilise a cone as the system's primary element are increasingly being used to measure wet natural gas flows (i.e. mixtures of natural gas, light hydrocarbon liquids and water). It is therefore important to understand this meter's response to wet natural gas flows. Research into the wet gas response of the horizontally installed cone DP meter is discussed in this paper. Consideration is given to the significant influence of the liquid properties on wet gas flow patterns and the corresponding influence of the flow pattern on the cone DP meter's liquid phase induced gas flow rate prediction error. A wet natural gas flow correlation for 4 in. 0.75 beta ratio cone DP meters with natural gas, hydrocarbon liquid and water flow has been developed from multiple data sets from three different wet gas flow test facilities. This corrects the liquid induced gas flow rate prediction error of a wet gas flow up to a Lockhart-Martinelli parameter of 0.3, for a known liquid flow rate of any hydrocarbon liquid/water ratio, to +/-4% at a 95% confidence level. (C) 2008 Elsevier Ltd. All rights reserved.
引用
收藏
页码:152 / 167
页数:16
相关论文
共 50 条
  • [1] Performance of a horizontally mounted Venturi in low-pressure wet gas flow
    Fang Lide
    Zhang Tho
    [J]. CHINESE JOURNAL OF CHEMICAL ENGINEERING, 2008, 16 (02) : 320 - 324
  • [2] Venturi meter performance in wet gas flow
    DeLeeuw, H
    [J]. 8TH INTERNATIONAL CONFERENCE ON MULTIPHASE '97 - HOW DEEP? HOW FAR? HOW SOON?, 1997, (24): : 567 - 582
  • [3] Wet gas metering with a horizontally mounted Venturi meter
    Steven, RN
    [J]. FLOW MEASUREMENT AND INSTRUMENTATION, 2002, 12 (5-6) : 361 - 372
  • [4] Orifice plate meter wet gas flow performance
    Steven, Richard
    Hall, Andrew
    [J]. FLOW MEASUREMENT AND INSTRUMENTATION, 2009, 20 (4-5) : 141 - 151
  • [5] TWO-PHASE PRESSURE DROP PREDICTION IN WET GAS FLOW THROUGH V-CONE METER
    He, Denghui
    Bai, Bofeng
    [J]. ASME FLUIDS ENGINEERING DIVISION SUMMER MEETING - 2014, VOL 1D: SYMPOSIA, 2014,
  • [6] A new model for wet gas flow measurement with V-cone meter
    He, Denghui
    Liu, Hai
    Zhang, Feng
    Li, Xing
    Zhou, Rifeng
    Bai, Bofeng
    [J]. Hsi-An Chiao Tung Ta Hsueh/Journal of Xi'an Jiaotong University, 2013, 47 (01): : 32 - 36
  • [7] A dimensional analysis of two phase flow through a horizontally installed Venturi flow meter
    Steven, Richard
    [J]. FLOW MEASUREMENT AND INSTRUMENTATION, 2008, 19 (06) : 342 - 349
  • [8] Wet gas performance of differential pressure flowmeters
    Evans, Russell
    Ifft, Stephen A.
    [J]. FEDSM 2007: PROCEEDINGS OF THE 5TH JOINT ASME/JSME FLUIDS ENGINEERING SUMMER CONFERENCE, VOL 2, PTS A AND B, 2007, : 195 - 200
  • [9] A new model for the V-Cone meter in low pressure wet gas metering
    He, Denghui
    Bai, Bofeng
    Xu, Yong
    Li, Xing
    [J]. MEASUREMENT SCIENCE AND TECHNOLOGY, 2012, 23 (12)
  • [10] On fluctuation of the dynamic differential pressure signal of Venturi meter for wet gas metering
    Xu, LJ
    Xu, H
    Dong, F
    Zhang, T
    [J]. FLOW MEASUREMENT AND INSTRUMENTATION, 2003, 14 (4-5) : 211 - 217