Horizontally installed cone differential pressure meter wet gas flow performance

被引:39
|
作者
Steven, Richard [1 ]
机构
[1] Multiphase & Wet Gas Flow Res Colorado Engn Exp S, Nunn, CO 80648 USA
关键词
Two phase; Multiphase; Wet gas flow; Cone differential pressure; Venturi meter;
D O I
10.1016/j.flowmeasinst.2008.06.002
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Differential pressure (DP) meters which utilise a cone as the system's primary element are increasingly being used to measure wet natural gas flows (i.e. mixtures of natural gas, light hydrocarbon liquids and water). It is therefore important to understand this meter's response to wet natural gas flows. Research into the wet gas response of the horizontally installed cone DP meter is discussed in this paper. Consideration is given to the significant influence of the liquid properties on wet gas flow patterns and the corresponding influence of the flow pattern on the cone DP meter's liquid phase induced gas flow rate prediction error. A wet natural gas flow correlation for 4 in. 0.75 beta ratio cone DP meters with natural gas, hydrocarbon liquid and water flow has been developed from multiple data sets from three different wet gas flow test facilities. This corrects the liquid induced gas flow rate prediction error of a wet gas flow up to a Lockhart-Martinelli parameter of 0.3, for a known liquid flow rate of any hydrocarbon liquid/water ratio, to +/-4% at a 95% confidence level. (C) 2008 Elsevier Ltd. All rights reserved.
引用
收藏
页码:152 / 167
页数:16
相关论文
共 50 条
  • [41] Wet gas metering using double differential pressure device
    Xu, Ying
    Zhang, Qiang
    Yu, Lei
    Duan, Yuhan
    Li, Tao
    [J]. Yi Qi Yi Biao Xue Bao/Chinese Journal of Scientific Instrument, 2010, 31 (08): : 1840 - 1847
  • [42] Wet Gas Measurement with Slotted Orifice Meter-Effect of Geometry of Slots and Pressure
    Kumar, Perumal
    Chai, Boon Foo
    Bing, Michael Wong Ming
    [J]. CHEMICAL PRODUCT AND PROCESS MODELING, 2011, 6 (01):
  • [43] Experimental Evaluation of an Intravascular Differential Pressure Flow Meter using MEMS Pressure Sensors
    Satyamurthy, Kumar Swamy Hosur
    Timpson, Erik
    Leon-Salas, Walter Daniel
    [J]. 2011 IEEE SENSORS, 2011, : 1161 - 1164
  • [44] An experimental investigation of airfoil performance in wet gas flow
    Gruner, Trond Gl
    Bakken, Lars E.
    Brenne, Lars
    Bjorge, Tor
    [J]. PROCEEDINGS OF THE ASME TURBO EXPO 2008, VOL 7, 2008, : 575 - 584
  • [45] VOLUTE FLOW INFLUENCE ON WET GAS COMPRESSOR PERFORMANCE
    Bakken, Martin
    Bjorge, Tor
    [J]. PROCEEDINGS OF THE ASME GAS TURBINE INDIA CONFERENCE, 2017, VOL 1, 2018,
  • [46] Wet gas flow modeling for the straight section of throat-extended Venturi meter
    Zhou, Wanlu
    Xu, Lijun
    Li, Xiaomin
    [J]. 2010 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE I2MTC 2010, PROCEEDINGS, 2010,
  • [47] Experimental research on pressure drop of wet gas flow in Venturi
    Yuan, Chao
    Xu, Ying
    Zhang, Tao
    Wei, Jing
    Wang, Huaxiang
    [J]. EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2016, 75 : 183 - 188
  • [48] The effect of pressure and temperature on a meter for measuring the rate of flow of a gas.
    McLachlan, NW
    [J]. PROCEEDINGS OF THE PHYSICAL SOCIETY OF LONDON, 1920, 32 : 1 - 20
  • [49] Smart valve measures gas pressure and temperature to meter fuel flow
    [J]. Gas Turbine World, 2003, 33 (05): : 26 - 27
  • [50] Flow Rate Measurement of Oil/Gas/Water Three-Phase Flow with V-Cone Flow Meter
    Zhang, F. S.
    Dong, F.
    [J]. 6TH INTERNATIONAL SYMPOSIUM ON MULTIPHASE FLOW, HEAT MASS TRANSFER AND ENERGY CONVERSION, 2010, 1207 : 178 - 182