Wet gas performance of differential pressure flowmeters

被引:0
|
作者
Evans, Russell [1 ]
Ifft, Stephen A. [1 ]
机构
[1] Rosemt Div, Boulder, CO 80301 USA
关键词
D O I
暂无
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Wet gas flow measurement is becoming vital to the natural gas production industry. New wells with marginal Outputs cannot justify gas-liquid separation equipment and Must transfer gas which contains some liquid volume. The flow measurement device on each well dictates the allocation earnings and must therefore provide gas flow measurement as accurately as possible. Several types of differential pressure based flowmeters are currently being used in wet gas flow measurement. DP based flowmeters share many performance characteristics in wet gas applications. However. studies have also found that there can be significant differences in the correlations between meter over reading and liquid content depending of the type of DP meter being tested. Emerson Process Management conducted a series of wet gas tests on a standard orifice plate, a V-Cone, a Venturi an two Rosemount conditioning orifice plates at the National Engineering Laboratory in Scotland (NEL). Previously, tests of conditioning orifice plates in wet gas were conducted at the Colorado Engineering Experiment Station, Inc. (CEESI). The work described in this paper is aimed at investigating the similarities and differences in the performance of these meter types in wet gas flows. Comparisons of these data to those from previous studies on the meter types tested are presented. Also. as a result of these studies, a general method for correcting the over-reading of DP-based, wet gas flowmeters using process measurements and the flow computing capabilities of modern multivariable DP transmitters was developed and is presented.
引用
收藏
页码:195 / 200
页数:6
相关论文
共 50 条
  • [1] Modern water flowmeters Differential pressure flowmeters
    Sarbu, Gabriel Constantin
    [J]. PROCEEDINGS OF THE 2016 INTERNATIONAL CONFERENCE AND EXPOSITION ON ELECTRICAL AND POWER ENGINEERING (EPE 2016), 2016, : 609 - 615
  • [2] DIFFERENTIAL-PRESSURE FLOWMETERS
    RUDBACK, S
    MAYO, C
    [J]. MEASUREMENTS & CONTROL, 1994, (166): : 161 - 168
  • [3] Differential-pressure flowmeters
    Standard, D
    [J]. MEASUREMENTS & CONTROL, 1998, (190): : 170 - +
  • [4] Performance evaluation of piezoelectric and differential pressure sensor for vortex flowmeters
    Venugopal, A.
    Agrawal, Amit
    Prabhu, S. V.
    [J]. MEASUREMENT, 2014, 50 : 10 - 18
  • [5] Horizontally installed cone differential pressure meter wet gas flow performance
    Steven, Richard
    [J]. FLOW MEASUREMENT AND INSTRUMENTATION, 2009, 20 (4-5) : 152 - 167
  • [6] Differential flow calibration of turbine flowmeters for air and high pressure natural gas
    Liu, Yiping
    Li, Haiyang
    Wu, Jinchuan
    Shen, Qiong
    Quan, Xiaojun
    [J]. Natural Gas Industry, 2020, 40 (01): : 119 - 124
  • [7] A low-pressure wet gas measurement method based on Venturi flowmeters and Gamma ray technology
    Zheng, Yongjian
    Wang, Zhengang
    Pan, Yanzhi
    Zhao, Yueqian
    [J]. Natural Gas Industry, 2019, 39 (09) : 117 - 122
  • [8] Modeling of coefficient of contraction of differential pressure flowmeters
    Dayev, Zh. A.
    Kairakbaev, A. K.
    [J]. FLOW MEASUREMENT AND INSTRUMENTATION, 2019, 66 : 128 - 131
  • [9] Design of multirange differential-pressure flowmeters
    Kozlov, AD
    Patrikeev, VG
    Mamonov, YV
    Frenklakh, MM
    [J]. MEASUREMENT TECHNIQUES USSR, 1995, 38 (07): : 769 - 772
  • [10] OMISSION FROM SURVEY OF DIFFERENTIAL-PRESSURE FLOWMETERS
    LAZENBY, BD
    [J]. CONTROL, 1967, 11 (104): : 58 - &