Wet gas performance of differential pressure flowmeters

被引:0
|
作者
Evans, Russell [1 ]
Ifft, Stephen A. [1 ]
机构
[1] Rosemt Div, Boulder, CO 80301 USA
关键词
D O I
暂无
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Wet gas flow measurement is becoming vital to the natural gas production industry. New wells with marginal Outputs cannot justify gas-liquid separation equipment and Must transfer gas which contains some liquid volume. The flow measurement device on each well dictates the allocation earnings and must therefore provide gas flow measurement as accurately as possible. Several types of differential pressure based flowmeters are currently being used in wet gas flow measurement. DP based flowmeters share many performance characteristics in wet gas applications. However. studies have also found that there can be significant differences in the correlations between meter over reading and liquid content depending of the type of DP meter being tested. Emerson Process Management conducted a series of wet gas tests on a standard orifice plate, a V-Cone, a Venturi an two Rosemount conditioning orifice plates at the National Engineering Laboratory in Scotland (NEL). Previously, tests of conditioning orifice plates in wet gas were conducted at the Colorado Engineering Experiment Station, Inc. (CEESI). The work described in this paper is aimed at investigating the similarities and differences in the performance of these meter types in wet gas flows. Comparisons of these data to those from previous studies on the meter types tested are presented. Also. as a result of these studies, a general method for correcting the over-reading of DP-based, wet gas flowmeters using process measurements and the flow computing capabilities of modern multivariable DP transmitters was developed and is presented.
引用
收藏
页码:195 / 200
页数:6
相关论文
共 50 条
  • [31] A Wet/Wet Differential Pressure Sensor for Measuring Vertical Hydraulic Gradient
    Fritz, Brad G.
    Mackley, Rob D.
    [J]. GROUND WATER, 2010, 48 (01) : 117 - 121
  • [32] COMPACT INSTALLATIONS FOR DIFFERENTIAL FLOWMETERS
    LAWS, EM
    OUAZANNE, AK
    [J]. FLOW MEASUREMENT AND INSTRUMENTATION, 1994, 5 (02) : 79 - 85
  • [33] Wet Gas Compressor Operation and Performance
    Bakken, Martin
    Bjorge, Tor
    Bakken, Lars E.
    [J]. PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2018, VOL 6A, 2019,
  • [34] Effect of ultrasonic noise generated by pressure control valves on ultrasonic gas flowmeters
    Kang, Woong
    Lee, Saeng-Hee
    Lee, Seung-Jun
    Ha, Young-Cheol
    Jung, Sung-Soo
    [J]. FLOW MEASUREMENT AND INSTRUMENTATION, 2018, 60 : 95 - 104
  • [35] FLOWMETERS - A PERFORMANCE REVIEW
    GINESI, D
    GREBE, G
    [J]. CHEMICAL ENGINEERING, 1987, 94 (09) : 102 - 118
  • [36] FLOWMETERS FOR THE MEASUREMENT OF GAS TEMPERATURES
    SCOTT, DS
    [J]. CHEMICAL ENGINEERING SCIENCE, 1960, 12 (02) : 127 - 132
  • [37] Wet Gas Over-reading Characteristic Research of Inside and Outside Tube Differential Pressure Flowmeter
    Fang, Lide
    Wang, Xiaojie
    Li, Xiaoting
    Pang, Lili
    Liang, Yujiao
    [J]. INDUSTRIAL INSTRUMENTATION AND CONTROL SYSTEMS, PTS 1-4, 2013, 241-244 : 168 - +
  • [38] ANALYTIC DETERMINATION OF LIMITING NOMINAL PRESSURE DIFFERENCE IN A DIFFERENTIAL MANOMETER AND RELATIVE STANDARD-ORIFICE PLATE AREAS FOR GAS AND VAPOR FLOWMETERS
    PISTUN, EP
    LESOVOI, LV
    KRUK, IS
    [J]. MEASUREMENT TECHNIQUES USSR, 1987, 30 (10): : 979 - 983
  • [39] DYNAMIC CALIBRATION OF GAS FLOWMETERS
    MASLEN, KR
    [J]. MEASUREMENT AND CONTROL, 1970, 3 (08): : 250 - &
  • [40] ACCURACY OF NEW GAS FLOWMETERS
    WAABEN, J
    BRINKLOV, MM
    STOKKE, DB
    [J]. BRITISH JOURNAL OF ANAESTHESIA, 1980, 52 (01) : 97 - 100