LC-MS/MS and GC-MS methods in propofol detection: Evaluation of the two analytical procedures

被引:24
|
作者
Vaiano, Fabio [1 ]
Serpelloni, Giovanni [1 ]
Focardi, Martina [2 ]
Fioravanti, Alessia [1 ]
Mari, Francesco [1 ]
Bertol, Elisabetta [1 ]
机构
[1] Univ Florence, Forens Toxicol Div, Dept Hlth Sci, I-50134 Florence, Italy
[2] Univ Florence, Forens Med Sect, Dept Hlth Sci, I-50134 Florence, Italy
关键词
Propofol; LC-MS/MS; Azo-coupling; GC-MS; Propofol postmortem distribution; TANDEM MASS-SPECTROMETRY; OF-THE-LITERATURE; LIQUID-CHROMATOGRAPHY; HAIR ANALYSIS; HUMAN PLASMA; ABUSE; DERIVATIZATION; DEATH; METABOLITES; LETHAL;
D O I
10.1016/j.forsciint.2015.07.013
中图分类号
DF [法律]; D9 [法律]; R [医药、卫生];
学科分类号
0301 ; 10 ;
摘要
Propofol is a short-acting hypnotic agent that is commonly used to induce and maintain anesthesia. Propofol abuse and its involvement in suicide deaths have increased in recent years, especially among healthcare personnel. An example is the suicide of a 61-year-old nurse found with a propofol drip in his left arm. We describe the postmortem concentration of propofol in various tissues (femoral and cardiac blood, bile, urine, brain, and liver) and in the drip. The toxicological analyses were performed through two analytical methods, differing in derivatization reaction and in instrumentation: silylation for gas chromatograph-mass spectrometer (GC-MS), as routinely performed in our laboratory for this kind of analyses (lower limits of quantification-LLOQ-in urine and blood: 0.3 and 5 ng/ml); for liquid chromatograph-tandem mass spectrometer (LC-MS/MS) an innovative azo-coupling derivatization (LLOQ: 0.0004 and 0.1 ng/ml). This latter produces an azo-derivative (molecular composition: C18H22ON2; molecular weight: 282 Da) highly ionizable in electro-spray ion source, both in negative and positive ionizations. These two methods were compared to evaluate the effectiveness of this new LC-MS/MS analysis. An acidic hydrolysis (HCl 6 N, 100 degrees C, and 1 h) was performed for the biological samples (1 ml or 1 g) irrespective of the analytical method applied. The drip content was extracted adding phosphate buffer (pH 8) and a dichloromethane/ethylacetate 8: 2 (v:v) mixture. Derivatization steps were: silylation with N, O-bis(trimethylsilyl) trifluoroacetamide (BSTFA) + tetramethylammonium hydroxide (TMAH) for GC-MS; regarding LC-MS/MS, azo-coupling reaction with the aryl-diazonium salt (0-5 degrees C, and 30 min). The analyses were achieved in selected-ion monitoring for GC-MS (m/z, 235,250,73 propofol''; m/z, 252,267,27 propofol-d17) and in multiple reaction monitoring ([M - H] : m/z 283 -> 241,77, azo-propofol; m/z 299 -> 251,77, azo-propofol-d17) for LC-MS/MS. Autopsy showed no significant findings. Propofol concentrations were (LC-MS/MS vs GC-MS, respectively): 15.1 vs 14.5 mg/ml, drip content; 7.11 vs 6.07 mu g/ml, cardiac blood; 9.50 vs 7.19 mu g/ml, femoral blood; 0.64 vs 1.07 mu g/ml, bile; 0.042 vs 0.051 mu g/ml urine; 4.93 vs 5.89 mu g/g, brain; and 7.88 vs 6.80 mu g/g, liver. These values are comparable with the ones described in literature for death by acute propofol intoxication; the drip content is compatible with a diluted formulation of propofol available in Italy (20 mg/ml injectable emulsion). The comparison shows an excellent fitting of the data (R-2: 0.9362). Toxicological results proved the cause of death as acute propofol intoxication. Furthermore, the new LC-MS/MS method showed an excellent effectiveness and reliability when compared to the routinely used GC-MS method. (C) 2015 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:1 / 6
页数:6
相关论文
共 50 条
  • [41] BYOG: HYDROGEN AND NITROGEN GAS GENERATORS IN GC-MS AND LC-MS
    Cook, Brandoch
    [J]. Lab Manager, 2019, 14 (09): : 50 - 51
  • [42] LC-MS and GC-MS based metabolomics platform for cancer research
    Wenyun Lu
    Sisi Zhang
    Xin Teng
    Eugene Melamud
    Mitchell A Lazar
    Eileen White
    Joshua D Rabinowitz
    [J]. Cancer & Metabolism, 2 (Suppl 1)
  • [43] Electronic cigarette solution and vapor analysis with GC-MS and LC-MS
    Lazernik, Michael
    Cole, Preston
    Jones, Martin
    Shamp, Brian
    Dormedy, Derek
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2017, 253
  • [44] Derivatization of steroids in biological samples for GC-MS and LC-MS analyses
    Marcos, Josep
    Pozo, Oscar J.
    [J]. BIOANALYSIS, 2015, 7 (19) : 2515 - 2536
  • [45] LC-MS and GC-MS based metabolomics platform for cancer research
    Lu, Wenyun
    Zhang, Sisi
    Teng, Xin
    Melamud, Eugene
    Lazar, Mitchell A.
    White, Eileen
    Rabinowitz, Joshua D.
    [J]. CANCER & METABOLISM, 2014, 2
  • [46] Analysing multi-class pesticide residues in tilapia fish: development and validation of LC-MS/MS and GC-MS/MS methods
    Mamdouh, Mohamed
    Amer, Mohamed E.
    Omran, Ahmed A.
    [J]. INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2024,
  • [47] A combined GC-MS, LC-MS and NMR metabonomics approach for early detection of ochratoxin a nephrotoxicity
    Sieber, M.
    Wagner, S.
    Rached, E.
    Amberg, A.
    Mally, A.
    Dekant, W.
    [J]. NAUNYN-SCHMIEDEBERGS ARCHIVES OF PHARMACOLOGY, 2008, 377 : 74 - 74
  • [48] Residue analysis of 500 high priority pesticides: Better by GC-MS or LC-MS/MS?
    Alder, Lutz
    Greulich, Kerstin
    Kempe, Guenther
    Vieth, Barbel
    [J]. MASS SPECTROMETRY REVIEWS, 2006, 25 (06) : 838 - 865
  • [49] Simultaneous quantification of nicotine salts in e-liquids by LC-MS/MS and GC-MS
    Han, Shulei
    Chen, Huan
    Su, Yue
    Cui, Lili
    Feng, Pengxia
    Fu, Ya'ning
    Tian, Yushan
    Liu, Tong
    Hou, Hongwei
    Hu, Qingyuan
    [J]. ANALYTICAL METHODS, 2022, 14 (42) : 4185 - 4192
  • [50] Identification of the chemical constituents in Cullen corylifolium ethanolic extract by LC-MS/MS and GC-MS
    Wang, Hongzheng
    Chen, Keyu
    Xue, Rui
    Turghun, Chimengul
    Han, Bo
    [J]. NATURAL PRODUCT RESEARCH, 2023, 37 (08) : 1392 - 1396