A Novel Wearable Foot and Ankle Monitoring System for the Assessment of Gait Biomechanics

被引:7
|
作者
Farago, Paul [1 ]
Grama, Lacrimioara [1 ]
Farago, Monica-Adriana [2 ]
Hintea, Sorin [1 ]
机构
[1] Tech Univ Cluj Napoca, Fac Telecommun & Informat Technol, Bases Elect Dept, Elect, Cluj Napoca 400114, Romania
[2] Univ Oradea, Fac Med & Pharm, Psychoneurosci & Rehabil Dept, Oradea 410087, Romania
来源
APPLIED SCIENCES-BASEL | 2021年 / 11卷 / 01期
关键词
EMG; resistive pressure sensor; footprint; center of pressure progression line; microcontroller; smart-shoe; cross-correlation; gait analysis; gait physiology; gait biomechanics; GASTROCNEMIUS; BALANCE; SOLEUS; KINEMATICS; PARAMETERS; MUSCLES; MODELS; OXFORD; FORCE;
D O I
10.3390/app11010268
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Featured Application: A wearable monitoring system for the assessment of walking physiology. Walking is the most basic form of human activity for achieving mobility. As an essential function of the human body, the examination of walking is directed towards the assessment of body mechanics in posture and during movement. This work proposes a wearable smart system for the monitoring and objective evaluation of foot biomechanics during gait. The proposed solution assumes the cross-correlation of the plantar pressure with lower-limb muscular activity, throughout the stance phase of walking. Plantar pressure is acquired with an array of resistive pressure sensors deployed onto a shoe insole along the center of gravity progression line. Lower-limb muscular activity is determined from the electromyogram of the tibialis anterior and gastrocnemius lower limb muscles respectively. Under this scenario, physiological gait assumes the interdependency of plantar pressure on the heel area with activation of the tibialis anterior, as well as plantar pressure on the metatarsal arch/toe area with activation of the gastrocnemius. As such, assessment of gait physiology is performed by comparison of a gait map, formulated based on the footprint-lower-limb muscle cross-correlation results, to a reference gait template. A laboratory proof of concept validates the proposed solution in a test scenario which assumes a normal walking and two pathological walking patterns.
引用
收藏
页码:1 / 29
页数:31
相关论文
共 50 条
  • [31] A novel wearable system for elderly monitoring
    Faetti, Tommaso
    Paradiso, Rita
    WEARABLE/WIRELESS BODY SENSOR NETWORKS FOR HEALTHCARE APPLICATIONS, 2013, 85 : 17 - 22
  • [32] The Effects of Chronic Ankle Instability on the Biomechanics of the Uninjured, Contralateral Ankle During Gait
    Ziaei Ziabari, Elaheh
    Haghpanahi, Mohammad
    Razi, Mohammad
    Lubberts, Bart
    Ashkani-Esfahani, Soheil
    DiGiovanni, Christopher W.
    ORTHOPAEDIC SURGERY, 2022, 14 (09) : 2238 - 2244
  • [33] Biomechanics of the Ageing Foot and Ankle: A Mini-Review
    Menz, Hylton B.
    GERONTOLOGY, 2015, 61 (04) : 381 - 388
  • [34] BIOMECHANICS OF ANKLE-FOOT ORTHOSES - PRESCRIPTION AND DESIGN
    LEHMANN, JF
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 1979, 60 (05): : 200 - 207
  • [35] Running gait biomechanics in females with chronic ankle instability and ankle sprain copers
    Koldenhoven, Rachel M.
    Hart, Joseph
    Abel, Mark F.
    Saliba, Susan
    Hertel, Jay
    SPORTS BIOMECHANICS, 2022, 21 (04) : 447 - 459
  • [36] EFFECTS OF ANKLE FOOT ORTHOSES ON THE GAIT OF CHILDREN
    BRODKE, DS
    SKINNER, SR
    LAMOREUX, LW
    JOHANSON, ME
    STHELEN, R
    MORAN, SA
    ASHLEY, RK
    JOURNAL OF PEDIATRIC ORTHOPAEDICS, 1989, 9 (06) : 702 - 708
  • [37] Design of a Novel Wearable System for Foot Clearance Estimation
    Jacob, Shilpa
    Fernie, Geoff
    Roshan Fekr, Atena
    SENSORS, 2021, 21 (23)
  • [38] Feasibility and Preliminary Efficacy of a Foot-Ankle Exercise Program Aiming to Improve Foot-Ankle Functionality and Gait Biomechanics in People with Diabetic Neuropathy: A Randomized Controlled Trial
    Monteiro, Renan L.
    Ferreira, Jane S. S. P.
    Silva, Erica Q.
    Donini, Asha
    Cruvinel-Junior, Ronaldo H.
    Verissimo, Jady L.
    Bus, Sicco A.
    Sacco, Isabel C. N.
    SENSORS, 2020, 20 (18) : 1 - 18
  • [39] Total ankle arthroplasty and ankle arthrodesis affect the biomechanics of the inner foot differently
    Wang, Yan
    Wong, Duo Wai-Chi
    Tan, Qitao
    Li, Zengyong
    Zhang, Ming
    SCIENTIFIC REPORTS, 2019, 9 (1)
  • [40] Clinical validation of a system for the analysis of pediatric foot and ankle kinematics during gait
    Sampath, G
    Abu-Faraj, ZO
    Smith, PA
    Harris, GF
    PROCEEDINGS OF THE 20TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 20, PTS 1-6: BIOMEDICAL ENGINEERING TOWARDS THE YEAR 2000 AND BEYOND, 1998, 20 : 2418 - 2421