A Novel Wearable Foot and Ankle Monitoring System for the Assessment of Gait Biomechanics

被引:7
|
作者
Farago, Paul [1 ]
Grama, Lacrimioara [1 ]
Farago, Monica-Adriana [2 ]
Hintea, Sorin [1 ]
机构
[1] Tech Univ Cluj Napoca, Fac Telecommun & Informat Technol, Bases Elect Dept, Elect, Cluj Napoca 400114, Romania
[2] Univ Oradea, Fac Med & Pharm, Psychoneurosci & Rehabil Dept, Oradea 410087, Romania
来源
APPLIED SCIENCES-BASEL | 2021年 / 11卷 / 01期
关键词
EMG; resistive pressure sensor; footprint; center of pressure progression line; microcontroller; smart-shoe; cross-correlation; gait analysis; gait physiology; gait biomechanics; GASTROCNEMIUS; BALANCE; SOLEUS; KINEMATICS; PARAMETERS; MUSCLES; MODELS; OXFORD; FORCE;
D O I
10.3390/app11010268
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Featured Application: A wearable monitoring system for the assessment of walking physiology. Walking is the most basic form of human activity for achieving mobility. As an essential function of the human body, the examination of walking is directed towards the assessment of body mechanics in posture and during movement. This work proposes a wearable smart system for the monitoring and objective evaluation of foot biomechanics during gait. The proposed solution assumes the cross-correlation of the plantar pressure with lower-limb muscular activity, throughout the stance phase of walking. Plantar pressure is acquired with an array of resistive pressure sensors deployed onto a shoe insole along the center of gravity progression line. Lower-limb muscular activity is determined from the electromyogram of the tibialis anterior and gastrocnemius lower limb muscles respectively. Under this scenario, physiological gait assumes the interdependency of plantar pressure on the heel area with activation of the tibialis anterior, as well as plantar pressure on the metatarsal arch/toe area with activation of the gastrocnemius. As such, assessment of gait physiology is performed by comparison of a gait map, formulated based on the footprint-lower-limb muscle cross-correlation results, to a reference gait template. A laboratory proof of concept validates the proposed solution in a test scenario which assumes a normal walking and two pathological walking patterns.
引用
收藏
页码:1 / 29
页数:31
相关论文
共 50 条
  • [21] Biomechanical modelling for quantitative assessment of gait kinematics in drop foot patients with ankle foot orthosis
    Coccia, Armando
    Amitrano, Federica
    Pagano, Gaetano
    Dileo, Lucia
    Marsico, Vito
    Tombolini, Giuseppe
    D'Addio, Giovanni
    2022 IEEE INTERNATIONAL SYMPOSIUM ON MEDICAL MEASUREMENTS AND APPLICATIONS (MEMEA 2022), 2022,
  • [22] Gait parameters and energy expenditure assessment with the novel wearable WI-SHOE system
    Philimis, Panayiotis
    Giusti, Alessandro
    Torres, Albert
    Mărgăritescu, Mihai
    Giakas, Giannis
    Romanian Review Precision Mechanics, Optics and Mechatronics, 2015, 2015 (48): : 271 - 272
  • [23] Monitoring gait in multiple sclerosis with novel wearable motion sensors
    Moon, Yaejin
    McGinnis, Ryan S.
    Seagers, Kirsten
    Motl, Robert W.
    Sheth, Nirav
    Wright, John A., Jr.
    Ghaffari, Roozbeh
    Sosnoff, Jacob J.
    PLOS ONE, 2017, 12 (02):
  • [24] KINETIC AND KINEMATIC GAIT ASSESSMENT OF PARAPLEGIC PATIENTS WITH AND WITHOUT ANKLE FOOT ORTHOSES
    Braga Machado de Azevedo, Eliza Regina Ferreira
    Azevedo Cacho, Enio Walker
    Alonso, Karina Cristina
    Bueno Martin, Fernando Tadeu
    Cliquet Junior, Alberto
    BIODEVICES 2010: PROCEEDINGS OF THE THIRD INTERNATIONAL CONFERENCE ON BIOMEDICAL ELECTRONICS AND DEVICES, 2010, : 98 - 102
  • [25] Ankle and foot power in gait analysis: Implications for science, technology and clinical assessment
    Zelik, Karl E.
    Honert, Eric C.
    JOURNAL OF BIOMECHANICS, 2018, 75 : 1 - 12
  • [26] A Wearable System for Continuous Monitoring and Assessment of Speech, Gait, and Cognitive Decline for Early Diagnosis of ADRD
    Dieffenderfer, James
    Brewer, Alec
    Noonan, Maxwell A.
    Smith, Madeline
    Eichenlaub, Emily
    Haley, Katarina L.
    Jacks, Adam
    Lobaton, Edgar
    Neupert, Shevaun D.
    Hess, Thomas M.
    Franz, Jason R.
    Ghosh, Sujit K.
    Misra, Veena
    Bozkurt, Alper
    2023 45TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY, EMBC, 2023,
  • [27] Gait assessment during the initial fitting of an ankle foot orthosis in individuals with stroke
    Rao, Noel
    Chaudhuri, Gouri
    Hasso, Daniel
    D'Souza, Keith
    Wening, Jason
    Carlson, Cheryl
    Aruin, Alexander S.
    DISABILITY AND REHABILITATION-ASSISTIVE TECHNOLOGY, 2008, 3 (04) : 201 - 207
  • [28] Gait assessment of fixed ankle-foot orthoses in children with spastic diplegia
    Abel, MF
    Juhl, GA
    Vaughan, CL
    Damiano, DL
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 1998, 79 (02): : 126 - 133
  • [29] Best Practice Use Of Wearable Accelerometers In Gait Biomechanics
    Addleman, Jennifer S.
    Hawkins, David
    MEDICINE & SCIENCE IN SPORTS & EXERCISE, 2020, 52 (07) : 938 - 938
  • [30] A systematic review and meta-analysis of the effect of an ankle-foot orthosis on gait biomechanics after stroke
    Tyson, S. F.
    Sadeghi-Demneh, E.
    Nester, C. J.
    CLINICAL REHABILITATION, 2013, 27 (10) : 879 - 891