Measurement of internal pressure and thermal performance in a closed-loop oscillating heat-pipe with check valves (CLOHP/CV)

被引:0
|
作者
Sangiamsuk, S. [1 ]
Bubphachot, B. [1 ]
Watanabe, O. [2 ]
Rittidech, S. [1 ]
机构
[1] Mahasarakham Univ, Fac Engn, Dept Mech Engn, Heat Pipe & Thermal Tools Design Res Unit HTDR, Maha Sarakham, Thailand
[2] Univ Tsukuba, Fac Syst & Informat Engn, Dept Engn Mech & Energy, Tsukuba, Ibaraki 305, Japan
关键词
Closed-loop oscillating heat-pipe with check valves; Heat transfer; Thermal performance; Thermal resistance; Inclination angle;
D O I
暂无
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
The internal pressure and the thermal performance as characteristic parameters in a closed-loop oscillating heat-pipe with check valves (CLOHP/CV) under the normal operating condition have been investigated experimentally. The test CLOHP/CV was made of a copper capillary tube with various inner diameters. The inclination angle and the working temperature have been varied in the experiments. The working fluids of distilled water, ethanol and R123 were used with a filling ratio 50% of the total internal tube volume; the number of meandering turns was 40 and the number of check valves was 2. The lengths of the evaporator, adiabatic and condenser sections are all the same. The evaporator section was heated by electric strip heaters. The heat was removed from the condenser section by forced convective flow of ambient air blowing through the sections. The adiabatic section was well insulated by foam insulation. The thermal performance of the CLOHP/CV was evaluated by calculating the rate of heat transferred from the condenser to ambient air. It was found that the thermal performance of the CLOHP/CV has been improved by increasing the working temperature, the inclination angle and the inner diameter. The best performance of all the test CLOHP/CVs occurred for the case of R123 as working fluid, 2.03 mm inner diameter, 90 inclination angle and the working temperature of 200 degrees C, where the maximum internal pressure was 7.53 MPa and the minimum thermal resistance was 0.048 degrees C/W.
引用
收藏
页码:531 / 540
页数:10
相关论文
共 50 条
  • [41] Influence of the channel profile on the thermal resistance of closed-loop flat-plate oscillating heat pipe
    Kamlesh Mehta
    Nirvesh Mehta
    Vivek Patel
    Journal of the Brazilian Society of Mechanical Sciences and Engineering, 2020, 42
  • [42] Application of silver nanoparticles contained in ethanol as a working fluid in an oscillating heat pipe with a check valve (CLOHP/CV): a thermodynamic behaviour study
    N. Bhuwakietkumjohn
    T. Parametthanuwat
    Heat and Mass Transfer, 2015, 51 : 1219 - 1228
  • [43] Application of silver nanoparticles contained in ethanol as a working fluid in an oscillating heat pipe with a check valve (CLOHP/CV): a thermodynamic behaviour study
    Bhuwakietkumjohn, N.
    Parametthanuwat, T.
    HEAT AND MASS TRANSFER, 2015, 51 (09) : 1219 - 1228
  • [44] Investigation on the performance of closed-loop pulsating heat pipe with surfactant
    Wang, Jiansheng
    Xie, Jinyuan
    Liu, Xueling
    APPLIED THERMAL ENGINEERING, 2019, 160
  • [45] Motion and Heat-Transfer Analysis of a Closed-Loop Oscillating Heat Pipe with a Magnetic Field
    Wongkasem, K.
    Rittidech, S.
    Bubphachot, B.
    JOURNAL OF ENHANCED HEAT TRANSFER, 2010, 17 (04) : 369 - 380
  • [46] Experimental study on the thermal performance of vertical closed-loop oscillating heat pipes and correlation modeling
    Qu, Jian
    Wang, Qian
    APPLIED ENERGY, 2013, 112 : 1154 - 1160
  • [47] Experimental investigation on the thermal performance of a closed oscillating heat pipe in thermal management
    Zhonghao Rao
    Qingchao Wang
    Jiateng Zhao
    Congliang Huang
    Heat and Mass Transfer, 2017, 53 : 3059 - 3071
  • [48] Experimental investigation on the thermal performance of a closed oscillating heat pipe in thermal management
    Rao, Zhonghao
    Wang, Qingchao
    Zhao, Jiateng
    Huang, Congliang
    HEAT AND MASS TRANSFER, 2017, 53 (10) : 3059 - 3071
  • [49] VISUAL STUDY ON TWO-PHASE FLOW IN A HORIZONTAL CLOSED-LOOP OSCILLATING HEAT PIPE
    Charoensawan, Piyanun
    Terdtoon, Pradit
    THERMAL SCIENCE, 2019, 23 (02): : 1055 - 1065
  • [50] Thermal characteristics of an ammonia-charged closed-loop pulsating heat pipe
    Md Shahidul Haque
    Antara Majumdar
    Md. Faisal Kader
    Md. Mahbubur Razzaq
    Journal of Mechanical Science and Technology, 2019, 33 : 1907 - 1914