Measurement of internal pressure and thermal performance in a closed-loop oscillating heat-pipe with check valves (CLOHP/CV)

被引:0
|
作者
Sangiamsuk, S. [1 ]
Bubphachot, B. [1 ]
Watanabe, O. [2 ]
Rittidech, S. [1 ]
机构
[1] Mahasarakham Univ, Fac Engn, Dept Mech Engn, Heat Pipe & Thermal Tools Design Res Unit HTDR, Maha Sarakham, Thailand
[2] Univ Tsukuba, Fac Syst & Informat Engn, Dept Engn Mech & Energy, Tsukuba, Ibaraki 305, Japan
关键词
Closed-loop oscillating heat-pipe with check valves; Heat transfer; Thermal performance; Thermal resistance; Inclination angle;
D O I
暂无
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
The internal pressure and the thermal performance as characteristic parameters in a closed-loop oscillating heat-pipe with check valves (CLOHP/CV) under the normal operating condition have been investigated experimentally. The test CLOHP/CV was made of a copper capillary tube with various inner diameters. The inclination angle and the working temperature have been varied in the experiments. The working fluids of distilled water, ethanol and R123 were used with a filling ratio 50% of the total internal tube volume; the number of meandering turns was 40 and the number of check valves was 2. The lengths of the evaporator, adiabatic and condenser sections are all the same. The evaporator section was heated by electric strip heaters. The heat was removed from the condenser section by forced convective flow of ambient air blowing through the sections. The adiabatic section was well insulated by foam insulation. The thermal performance of the CLOHP/CV was evaluated by calculating the rate of heat transferred from the condenser to ambient air. It was found that the thermal performance of the CLOHP/CV has been improved by increasing the working temperature, the inclination angle and the inner diameter. The best performance of all the test CLOHP/CVs occurred for the case of R123 as working fluid, 2.03 mm inner diameter, 90 inclination angle and the working temperature of 200 degrees C, where the maximum internal pressure was 7.53 MPa and the minimum thermal resistance was 0.048 degrees C/W.
引用
收藏
页码:531 / 540
页数:10
相关论文
共 50 条
  • [31] Experimental investigation on thermal performance of phase change material coupled with closed-loop oscillating heat pipe (PCM/CLOHP) used in thermal management (vol 93, pg 90, 2016)
    Zhao, Jiateng
    Rao, Zhonghao
    Liu, Chenzhen
    Li, Yimin
    APPLIED THERMAL ENGINEERING, 2017, 122 : 832 - 832
  • [32] Thermal Performance of a Closed-Loop Pulsating Heat Pipe With Multiple Heat Sources
    Kammuang-Lue, Niti
    Sakulchangsatjatai, Phrut
    Terdtoon, Pradit
    HEAT TRANSFER ENGINEERING, 2014, 35 (13) : 1161 - 1172
  • [33] Experimental study of flow state and heat transfer performance of closed-loop oscillating heat pipe
    Liu, Xiang-Dong
    Shi, Kai
    Guo, Yu-Han
    Lu, Jin-Li
    Wang, Shu-Juan
    Hao, Ying-Li
    Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2010, 31 (10): : 1735 - 1738
  • [34] Hot Air Dryer with Closed - Loop Oscillating Heat Pipe with Check Valves for Reducing Energy in Drying Process
    Wannapakhe, S.
    Chaiwong, T.
    Dandee, M.
    Prompakdee, S.
    ISEEC, 2012, 32 : 77 - 82
  • [35] Investigations into the thermal performance of a helically coiled closed loop oscillating heat pipe
    Yeboah, S. K.
    Darkwa, J.
    14TH INTERNATIONAL ENERGY CONVERSION ENGINEERING CONFERENCE, 2016,
  • [36] Experimental investigation of the thermal performance of closed loop flat plate oscillating heat pipe
    Mehta, Kamlesh
    Mehta, Nirvesh
    Patel, Vivek
    EXPERIMENTAL HEAT TRANSFER, 2021, 34 (01) : 85 - 103
  • [37] DEVELOPMENT OF A CLOSED-LOOP HEAT-PIPE FOR HEAT RECOVERY WITH MINI-CHANNELS ENHANCING EVAPORATION
    Rocha, Bruno Duarte
    Mazzoco, Rene Reyes
    PROCEEDINGS OF THE 6TH INTERNATIONAL CONFERENCE ON NANOCHANNELS, MICROCHANNELS, AND MINICHANNELS, PTS A AND B, 2008, : 661 - 667
  • [38] Heat transfer characteristics of a novel closed-loop pulsating heat pipe with a check valve
    Feng, Chen
    Wan, Zhenping
    Mo, Haijun
    Tang, Heng
    Lu, Longsheng
    Tang, Yong
    APPLIED THERMAL ENGINEERING, 2018, 141 : 558 - 564
  • [39] SOLAR CHEMICAL HEAT-PIPE IN CLOSED-LOOP OPERATION - MATHEMATICAL-MODEL AND EXPERIMENTS
    SEGAL, A
    LEVY, M
    SOLAR ENERGY, 1993, 51 (05) : 367 - 376
  • [40] Influence of the channel profile on the thermal resistance of closed-loop flat-plate oscillating heat pipe
    Mehta, Kamlesh
    Mehta, Nirvesh
    Patel, Vivek
    JOURNAL OF THE BRAZILIAN SOCIETY OF MECHANICAL SCIENCES AND ENGINEERING, 2020, 42 (03)