Inter-rater and intra-rater reliability of an adapted Wolf motor function test for older patients with shoulder injuries

被引:5
|
作者
Oberle, Corinna [1 ]
Becker, Clemens [1 ]
Schoelch, Sabine [1 ]
Lenz, Joerg-Uwe [2 ]
Studier-Fischer, Stefan [3 ]
Augat, Peter [4 ]
Schwickert, Lars [1 ]
机构
[1] Robert Bosch Krankenhaus, Dept Clin Gerontol, Auerbachstr 110, D-70376 Stuttgart, Germany
[2] Robert Bosch Krankenhaus, Dept Orthopaed & Trauma Surg, Stuttgart, Germany
[3] BG Trauma Ctr Ludwigshafen, Dept Trauma & Orthoped Surg, Ludwigshafen, Germany
[4] Paracelsus Med Univ, Inst Biomech, Salzburg, Austria
来源
关键词
PSYCHOMETRIC PROPERTIES; OUTCOME MEASURE; GRIP STRENGTH; STROKE; REHABILITATION; QUESTIONNAIRE; ARM; HEMIPARESIS; DISABILITY; AGREEMENT;
D O I
10.1007/s00391-017-1226-2
中图分类号
R592 [老年病学]; C [社会科学总论];
学科分类号
03 ; 0303 ; 100203 ;
摘要
The Wolf motor function test (WMFT) evaluates the upper extremity performance of patients with neurological disorders and traumatic brain injuries by assessing time and functional capacity. It was later modified to also measure the quality of the performed movements. This study aimed to adapt the WMFT for patients with shoulder injuries and to evaluate the inter-rater and intra-rater reliability of this adapted version. A total of 20 individuals with a median age of 80.5 years were assessed using a test-retest design after surgical or conservative treatment of shoulder injuries. Two raters rated performance to determine inter-rater reliability. One rater rated the performance again to determine intra-rater reliability. Both inter-rater and intra-rater agreement were determined by weighted Cohen's kappa statistics with corresponding confidence intervals. Cronbach's alpha was calculated to determine internal consistency. The inter-rater Cohen's kappa values ranged from 0.84-1.00 for functional capacity and from 0.79-1.00 for quality of movement. For intra-rater reliability the Cohen's kappa ranged from 0.71-1.00. Cronbach's alpha was > 0.94 for functional capacity and > 0.96 for quality of movement. The adapted version of the WMFT shows high intra-rater and inter-rater reliability for patients with shoulder injuries.
引用
收藏
页码:293 / 300
页数:8
相关论文
共 50 条
  • [41] INTER-RATER AND INTRA-RATER AGREEMENT OF THE REHABILITATION ACTIVITIES PROFILE
    JELLES, F
    VANBENNEKOM, CAM
    LANKHORST, GJ
    SIBBEL, CJP
    BOUTER, LM
    JOURNAL OF CLINICAL EPIDEMIOLOGY, 1995, 48 (03) : 407 - 416
  • [42] Inter-rater and intra-rater reliability of the UPDRS motor examination for nurse practitioners, residents and movement disorders experts
    Post, B
    Merkus, MP
    de Bie, RM
    Lemstra, W
    de Haan, RJ
    Speelman, JD
    MOVEMENT DISORDERS, 2004, 19 : S156 - S156
  • [43] Intra-rater and Inter-rater Reliability of the Commander Pressure Algometer in Greek Patients With Chronic Neck Pain
    Skordis, Charalampos
    Liaskou, Christina
    Papagiakoumou, Evangelia
    Sotiropoulos, Spyridon
    Plavoukou, Theodora
    Karakasidou, Palina
    Georgoudis, George
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (08)
  • [44] Intra-Rater and Inter-Rater Reliability of Hand-Held Dynamometry for Shoulder Strength Assessment in Circus Arts Students
    Ganderton, Charlotte
    Kerr, Bonnie
    King, Matthew
    Lenssen, Ross
    Warby, Sarah
    Munro, David
    Watson, Lyn
    Balster, Simon
    Han, Jia
    Tirosh, Oren
    MEDICAL PROBLEMS OF PERFORMING ARTISTS, 2021, 36 (02) : 88 - 102
  • [45] INTER-RATER, INTRA-RATER, AND INTER-MACHINE RELIABILITY OF QUANTITATIVE ULTRASOUND MEASUREMENTS OF THE PATELLAR TENDON
    Gellhorn, Alfred C.
    Carlson, M. Jake
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2013, 39 (05): : 791 - 796
  • [46] Inter-rater, intra-rater and inter-instrument reliability of an electrogoniometer to measure wrist range of motion
    da Silva Camassuti, Patricia Aparecida
    Marcolino, Alexandre Marcio
    Tamanini, Guilherme
    Barbosa, Rafael Inacio
    Barbosa, Amanda Matias
    Registro Fonseca, Marisa de Cassia
    HAND THERAPY, 2015, 20 (01) : 3 - 10
  • [47] The Inter-Rater and Intra-Rater Reliability of the Actual Aquatic Skills Test (AAST) for Assessing Young Children's Motor Competence in the Water
    Mertens, Lisa
    De Martelaer, Kristine
    Saeaekslahti, Arja
    D'Hondt, Eva
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2022, 19 (01)
  • [48] Inter and intra-rater reliability of the scoliometer
    Bonagamba, Guilherme H.
    Coelho, Daniel M.
    de Oliveira, Anamaria S.
    BRAZILIAN JOURNAL OF PHYSICAL THERAPY, 2010, 14 (05) : 432 - 437
  • [49] Assessment of the Human Factors Analysis and Classification System (HFACS): Intra-rater and inter-rater reliability
    Ergai, Awatef
    Cohen, Tara
    Sharp, Julia
    Wiegmann, Doug
    Gramopadhye, Anand
    Shappell, Scott
    SAFETY SCIENCE, 2016, 82 : 393 - 398
  • [50] Use of superpixels for improvement of inter-rater and intra-rater reliability during annotation of medical images
    Gut, Daniel
    Trombini, Marco
    Kucybala, Iwona
    Krupa, Kamil
    Rozynek, Milosz
    Dellepiane, Silvana
    Tabor, Zbislaw
    Wojciechowski, Wadim
    MEDICAL IMAGE ANALYSIS, 2024, 94