Intra-rater and Inter-rater Reliability of the Commander Pressure Algometer in Greek Patients With Chronic Neck Pain

被引:0
|
作者
Skordis, Charalampos [1 ]
Liaskou, Christina [1 ]
Papagiakoumou, Evangelia [1 ]
Sotiropoulos, Spyridon [1 ]
Plavoukou, Theodora [1 ]
Karakasidou, Palina [1 ]
Georgoudis, George [1 ]
机构
[1] Univ West Attica UNIWA, Physiotherapy Dept, Athens, Greece
关键词
commander; non-specific chronic neck pain; greek patients; inter-rater reliability; intra-rater reliability; pressure algometer; pressure pain threshold (ppt); SHORT-FORM; THRESHOLD; REPEATABILITY; INDIVIDUALS; SENSITIVITY; ASSOCIATION; VALIDITY; MUSCLES; PEOPLE;
D O I
10.7759/cureus.66350
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction Non-specific chronic neck pain (NSCNP) is a musculoskeletal disorder that affects 45%-54% of the general population. There is a strong correlation between patient-reported pain and mechanical pain pressure threshold (PPT) measured with an algometer. Purpose This study aims to investigate the intra- and inter-rater reliability of the Commander algometer in Greek NSCNP patients, in an urban primary care setting. Methods Thirty-three patients (22 women and 11 men) suffering from NSCNP (>3 months), the majority (42.4%) between the ages of 50 years and 59 years and overweight, were measured bilaterally both at the neck (mastoid, trapezius head-insertion and mid-portion, C5-C6 facet, insertion of levator scapula) and at the control areas (mid-deltoid and tibialis anterior) using the Commander algometer. Measurements were taken twice over a span of six days, by two raters, in a primary care setting. Intraclass correlation coefficient (ICC) statistics were used as measures of reliability (p = 0.05). Results Intra-rater reliability was "moderate to good" for both raters. ICC values for PPT at the seven bilaterally measured sites varied between 0.67 and 0.86 for the first rater (p < 0.001) and 0.64 and 0.82 for the second rater (p < 0.003). The inter-rater reliability was "moderate to excellent" (ICC = 0.68-0.92) in the first measurement (T1) and "moderate to good" (ICC = 0.68 to 0.89) in the second measurement (T2). Conclusion This study supports the intra- and inter-rater reliability of the Commander algometer in detecting reliably the mechanical PPT, in Greek NSCNP patients, as measured according to the procedures and methodology followed throughout this study.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Intra-rater and inter-rater reliability of pressure pain threshold assessment in stroke patients
    Zhang, Yong-Hui
    Wang, Yu-Chen
    Hu, Gong-Wei
    Ding, Xiao-Qin
    Shen, Xiao-Hua
    Ng, Hui Ya
    Rong, Ji-Feng
    Wang, Xue-Qiang
    EUROPEAN JOURNAL OF PHYSICAL AND REHABILITATION MEDICINE, 2022, 58 (04) : 549 - 557
  • [2] Measuring Essay Assessment: Intra-rater and Inter-rater Reliability
    Kayapinar, Ulas
    EURASIAN JOURNAL OF EDUCATIONAL RESEARCH, 2014, (57): : 113 - 135
  • [3] Intra-rater and inter-rater reliability of robotic arthrometer DYNEELAX®
    Mihalinec, Katja
    Martinez-Cepa, Carmen B.
    Zuil-Escobar, Juan C.
    Kejzar, Natasa
    Vauhnik, Renata
    JOURNAL OF EXPERIMENTAL ORTHOPAEDICS, 2024, 11 (03)
  • [4] Inter-rater and intra-rater reliability of nursing process records for patients with schizophrenia
    Chung, Min-Huey
    Chiang, I-Jen
    Chou, Kuei-Ru
    Chu, Hsin
    Chang, Hsiu-Ju
    JOURNAL OF CLINICAL NURSING, 2010, 19 (21-22) : 3023 - 3030
  • [5] Intra-rater and inter-rater reliability of cranio cervical flexion test in symptomatic subjects of neck pain using pressure biofeedback
    Rajalaxmi, V.
    Kotteswari, S.
    Nisha, R. Nithya
    Nallathambi, Mohan
    BANGLADESH JOURNAL OF MEDICAL SCIENCE, 2023, 22 (03): : 617 - 622
  • [6] Optoelectronic plethysmography: Intra-rater and inter-rater reliability in healthy subjects
    Vieira, Danielle S. R.
    Hoffman, Mariana
    Pereira, Danielle A. G.
    Britto, Raquel R.
    Parreira, Veronica F.
    RESPIRATORY PHYSIOLOGY & NEUROBIOLOGY, 2013, 189 (03) : 473 - 476
  • [7] INTER-RATER AND INTRA-RATER RELIABILITY OF UROFLOWMETRY INTERPRETATION IN ADULT WOMEN
    Rickey, Leslie M.
    Mueller, Elizabeth R.
    Newman, Diane K.
    Markland, Alayne D.
    Falke, Chloe
    Rudser, Kyle
    Lukacz, Emily S.
    JOURNAL OF UROLOGY, 2023, 209 : E519 - E519
  • [8] Inter-rater and intra-rater reliability of the airway diameter measured by sonography
    Gómez-Tamayo J.C.
    Puerta-Guarín J.I.
    Rojas-Camejo C.M.
    Caicedo J.P.
    Calvache J.A.
    Journal of Ultrasound, 2018, 21 (1) : 35 - 40
  • [9] Intra-rater and inter-rater reliability of the Empathic Communication Coding System
    Ju, Yu-Jeng
    Lee, Meng-Lin
    Chen, Jou-Chieh
    Wang, Yi-Ching
    Chen, Chih-Ping
    Tsai, Han-En
    Wu, Tzu-Yi
    Hsieh, Ching-Lin
    BRITISH JOURNAL OF OCCUPATIONAL THERAPY, 2025,
  • [10] INTER-RATER AND INTRA-RATER RELIABILITY OF BRIEF PSYCHIATRIC RATING SCALE
    FLEMENBAUM, A
    ZIMMERMANN, RL
    PSYCHOLOGICAL REPORTS, 1973, 32 (03) : 783 - 792